1 Answer

Pilot lights fine, furnace fires up, when it turns off the pilot goes out

I have a cozy wall furnace - probably 6-7 yrs old. The pilot lights fine and stays lit for many days, but every 3-4 days it will go out. Usually it is when the furnace has just kicked off as it shuts off, the pilot goes out as well. I have replaced the thermocouple - no fix. Any ideas?

Posted by on

  • glennpc Nov 19, 2008

    I have the same problem, but with a furnace instead of a wall heater. The pilot lights the burner and the blower starts, but when the burner shuts off it snuffs out the pilot. The pilot never goes out at any other time - only when the burner shuts off.

  • Ken Bledsoe May 11, 2010

    Is the pilot a good flame say at least 3/4 to 1 inch long?

×

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 59 Answers

Need to have at least 3 feet of vent out of the roof, if it is to low the coll air will cold soak down to the pilot and shut it down.

Posted on Oct 22, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Repairman can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Repairman (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Cozy W355D wall furnace. It's difficult to turn on. Replaced the thermostat, that helped some, but still have to turn it off, wait a few minutes, and turn it back on. Often still won't light.


So are you saying the pilot stays lit, but the main burner won't always fire. If this is a millivolt system you could have a weak pilot flame, not getting the pilot generator hot enough or you could have a weak pilot generator. If you are handy you can try cleaning the pilot. It may be better for a qualified service tech.

Jan 30, 2017 | Cozy Heating & Cooling

1 Answer

I AM WORKING ON A COZY W501E WALL FURNACE AND CANT GET THE PILOT TO STAY LIT. i HAVE CHANGED THE GAS VALVE, THERMOCOUPLE,AND THE SENSOR FOR THE HIGH LIMIT. THE PILOT WONT STAY LIT.


Pretty much the only thing that will do that is the thermocouple not generating enough voltage for the valve to say it's OK.
Usually you need to hold the button for pilot lighting for 60 seconds. You can use a meter to check that it's generating enough power. The thermocouple has to be in the pilot flame properly.

Check this video:
https://www.youtube.com/watch?v=suen7QlJl4o

Gas furnace will not light Thermocouple test with the multimeter

Or see this site:
How to Test Thermocouple with Multi Meter Heating and Cooling

Feb 11, 2015 | Cozy Heating & Cooling

1 Answer

Cozy gas wall heater won't ignite, pilot light is on


There are two types of igniters, spark-type or glow heater. The glow heaters wear out and crack or break and the spark-type spark gap gets fouled or dirty. Both could have electronics problems that drive the glow heater or spark systems. The Filtrete thermostat is not the issue. While rapping the unit makes the glow igniter come back together to glow again.

Jan 14, 2014 | Cozy Heating & Cooling

2 Answers

My cozy floor furnace wont come on


NEED MORE INFORMATION. IS THERE A LED LIGHT THAT FLASHES A CODE?. IS THE THERMOSTAT OPERATING PROPERLY? IS THIS UNITS FLUE EXHAUST VENTED TO THE OUTSIDE? & IS IT FREE OF OBSTRUCTIONS?,

Dec 25, 2012 | Cozy Heating & Cooling

1 Answer

The pilot will not stay lit in our Cozy Direct Vent Wall Furnace CDV335B. Problem occurs with winds. Last heating season, replaced powerpile, thermostat, ignitor, gas valve, and pilot burner. Any...


There is a wind shield for this unit, call 502-589-5380 and ask for a drawing for the wind shield and have it made out of 26 gauge sheet metal.

Nov 27, 2010 | Cozy (W352E) Heater

1 Answer

Cozy wall furnace (propane) does not respond to thermostat. The pilot is lit. Furnace is 3 yrs. old and rarely works. The wire to thermostat is 20 feet.


Try jumping the two thermostat wires together to see if the heater starts. If so, replace your thermostat. If not, jump the two terminals where the thermosta twires attach to the furnace. If it starts, you have a bad thermostat wire or connection.

Jan 30, 2010 | Cozy (W352E) Heater

1 Answer

Relatively new wall furnace suddenly stopped working.


if you are by passing stat at the gas valve and it is still not working,i would assume a bad control valve.

Jan 13, 2010 | Heating & Cooling

1 Answer

Cozy wall furnace model w255d pilot will not stay lit and thermopile has been replaced 750 millivolt system


Ensure the end of the thermopile is in direct flame, any lower or higher it will not allow the pilot to stay on..

Dec 04, 2008 | Heating & Cooling

Not finding what you are looking for?
Cozy (W352E) Heater Logo

1,160 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cozy Heating & Cooling Experts

Paul Carew

Level 3 Expert

3087 Answers

vance jones

Level 2 Expert

120 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Cozy Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...