Question about Air & Gas Compressors

1 Answer

Turbo i have a 99 F350 4x4 turbo crew cab.. truck ran real fine..till i had a new exsast instaled.. now runs like s..t.....took it back to the place that did it and told them it did nit smoke like this when i droped it off and now i also have oil running out of the turbo some were...........thay did atempt to fix it........but thay thought it was the full line and conection on the back of the head.......so tha replaced it at there cost not mine....now thay tell me that was not the trouble..it has oil comming from the turbo....... Thank u Mike

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 341 Answers

If you have oil running out of turbo it could be the gasket between the oil lineand the turbo or it might be the ceramic seal in the turbo

Posted on Nov 08, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Won't start


power 120 volt cannot to supply to 230 volt, maximum correction factor for voltage is 15%

Apr 04, 2014 | AO Smith 5 HP 3450rpm R56Y Frame 208-230...

1 Answer

My 1992 gmc diesel v8 turbo truck wont start


Is there enough water in the block to keep the glow plug controller from burning up? The controller sits in the water jacket in the intake manifold so it sits high.

Sep 28, 2013 | GMC 1992 3500 PICKUP A/C Compressor...

1 Answer

T30 air compressor has trouble starting and kicks breaker


check the breaker it needs to be motor rated for the surge on start up this will also be higher when motor is connected to the pump due to the extra torque placed on motor plus when cold oil losses viscocity and thickens therefore placing even more torque on motor

Dec 28, 2012 | Ingersoll Rand Type 30 Fully Packaged Ir...

2 Answers

PANCAKE COMPRESSOR WON'T SHUT OFF AND WON'T BUILD PRESSURE.


most likely the regulator is shoot. But also try checking for leaks with dish soap and water in a spray bottle.

Mar 06, 2011 | Clarke Power Products Inc AC2001 2HP 4...

1 Answer

Heres the probem-when I turn the compressor on,it acts like the motor brushes are bad. It turns about 3 rotations and quits. If I take the outlet line off the head,it runs fine. As soon as I hook the...


Hi,
It sounds like you have narrowed it down to the check valve...are you sure you are installing the check valve in the correct direction??? Can you blow through the check valve???
Seems like you have a real good handle on everything just need to find out why it won't work with the check...the check seems to be blocking the air flow for some reason...

heatman101

Sep 15, 2010 | Porter Cable Cable 135 PSI, 15 Gal. Oil -...

1 Answer

EC12 that fills fine, pressure switch kicks off, but then seems t


I have the same compressor with the same problem. I have temporarily eliminated the thermal reset with a piece of 12 gauge hard wire and it runs just fine. However, I do want to replace it before the warm weather come to the north. I tested the draw at 15.5 amps and the reset was a 17 amp. I am told by someone with superior electrical background that I need to install a 20 amp thermal reset in it's place. I have found that mine runs best when plugged directly into a 20 amp circuit and when using an extention cord I have a 10 guage cord that will carry the load needed to run the EC12.

Mar 15, 2010 | Hitachi EC12 Portable Electric 2hp Air...

1 Answer

My Mac5200 compressor was running fine. I took a


piston rings or valves in the head,,, valves are the most likely one.

Dec 13, 2009 | Makita MAC5200 Electric Powered Air...

1 Answer

Craftsman aircompressor bogging down


Yes , the check valve will cause this. The check valve has a flat disk with a spring that holds it down that the air passing past it erodes away till it leaks then the air that the piston pushes into the tank does not stay in the tank but returns right back into the cylinder and puts a load on the piston. Also makes the compressor hard to start back up if it does get pumped up. Some have a dump valve that drains the pressure off the head after they shut off so it can start with no load. So if there is air bleading back and leaking at the pressure swith that will be a for sure sign it is the check valve.

May 18, 2009 | Craftsman 3 gal. Air Compressor, 1.5 hp,...

1 Answer

Craftsman air compressor, oil build up in the air line


worn compressor rings, not a real issue, I assume it is more of a build up over time, say a gram of oil is blown into the lines every year, well one gram would not be noticed nor two but since it soes not evaporate it builds up to the point that you can see it, some oil is blown by brand new compressors and over time gets to be more and more, but as long as you are still getting full pressure you do not have to service the compressor, but since this is being used on water pipes I would install a trap inline to catch the oil

Oct 13, 2008 | Craftsman 3 gal. Air Compressor, 1.5 hp,...

Not finding what you are looking for?
Air & Gas Compressors Logo

Related Topics:

52 people viewed this question

Ask a Question

Usually answered in minutes!

Top Air & Gas Compressors Experts

John Trevino

Level 3 Expert

1378 Answers

JOHN LAPIER

Level 3 Expert

2380 Answers

yadayada
yadayada

Level 3 Expert

60541 Answers

Are you an Air and Gas Compressor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...