1 Answer

Not turning on


A. Is it plugged in?
B. Did you turn the Controls INSIDE the Freezer to the ON Position or to a lower setting?
C. Does the Light go on?
D. There is a Fuse that will blow (BUSS FUSE), you will need to change it if when you test it, there is power BEFORE and not after...

Jul 03, 2014 | Frigidaire Freezers

1 Answer

Kenmore freezer model C10BLEM blows circuits. I just bought it used. At original owners it worked well. I plug it in and after a couple of minutes it blows the circuit. I plugged it into the furnace...


If it is a chest freezer, almost certainly it is the compressor. Only way to check is to pull the power plug out then remove the compressor wires from the terminals then make sure it doesent touch the frame of the freezer, then plug the power back in and see if the power trips again. If not, there is the problem.

Aug 22, 2011 | Kenmore 22.7 cu. ft. / 643 liter Chest...

1 Answer

Head lights , keeps blowing the fuse every time i put a new in ?


Your fuse range is too small, change it with a bit higher range.

Jan 06, 2011 | Freezers

1 Answer

Aquired 3 door victory in existing bldg. Service


First check for bunrt wires that can be grounded, then you can disconnect the compressor and plug the freezer and if doesn't blow the breaker , the compressor is bad ,if still blows them ,put the compressor back and try the fan , then try the other fan(inside one) or also could be the light switch, or the defrost heaters.

Oct 06, 2009 | Victory Freezer Refrigeration ''Value''...

1 Answer

Hello I own a whirlpool Fridge + Freezer.


Hi lewis,

This is very suspect if it blew straight away I would suspect the compressor going to earth, I am still not convinced with the comp after all ts ten year life is up, It could be something to do with the thermal overload on the comp if it has one.
The compressor does run for 12 hours but in that twelve hours does it reach temp? does it actually switch off on its normal routine?
where about in the uk are you?

Jun 29, 2009 | Freezers

2 Answers

Please help my indesit ta 5 fnf s is dead with no warning. no lights no power nothing. its not fuse power or socket


Had the same problem with my TA5FNFS once you have confirmed as there is power in the wall socket and the fuse in the plug and cable are ok, I found as the PCB control board had burnt out costs about £60 for a replacement board

Apr 30, 2009 | Freezers

2 Answers

LOAD CLICKING SOUND WHEN PLUGED IN TO ELECTRIC


did you just get the freezer or move it recently? this unit doesnt have any fans so I'm thinking the compressor is somehow out of place and when you plug it in the compressor is hitting its steel shell from the inside. remove the compartment cover on the side then plug the freezer in and see if the compressor is making the noise..

Jan 22, 2009 | Freezers

1 Answer

My ice maker 10amps fuse burn out when turn on the machine


This may sound too simple. A fuse is a safety. It usually blows when the amps are higher than the fuse rating. Since yours blows immediately, I would look very closly for a pinched wire, a crossed wire, or a wire that has rubbed through. Once that is eliminated, start isolating components one at a time. Check their web site. It's pretty good. Also, their tech support line is pretty good. It's worth the wait. 1-800-233-1940.

Jan 22, 2009 | Hoshizaki Freezer Commercial Ice Machines...

1 Answer

Blows fusebox trip - all the time


good place to start is the starting device for the compressor.slip the cover off the compressor electrics on lhs of compressor usually and you may find the relay burnt out.tyhis is the mostly area but if elsewhere, look at the defrost element and check wiring loom

Apr 12, 2007 | AEG 7.59 cu. ft. / 215 liter Upright...

Not finding what you are looking for?
Turbo Air 49 cu. ft. / 1388 liter Commercial Freezer MSF-49NM Logo

Related Topics:

26 people viewed this question

Ask a Question

Usually answered in minutes!

Top Turbo Air Freezers Experts

Dennis Boxerman

Level 3 Expert

1070 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

marlin siecinski

Level 2 Expert

446 Answers

Are you a Turbo Air Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...