Question about Procom 10K BTU, Vent Free, 2 Plaque Infrared Space Heater, Natural Gas Infra-Red Patio

1 Answer

My ventless gas heater will not light

I have a good pilot on the heater but when I turn the control to light the burner, the pilot gets smaller and the heater won't light. The heater has ceramic tile and the flame will flicker over the tile but it acts as if it has air on it..

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Sergeant:

    An expert that has over 500 points.

  • Expert
  • 359 Answers

Gas pressure to low adjust 9 to 11 mb

Posted on Jan 22, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How do i light pilot light?


Remove front cover,or just lower section if you can. they usually just need to be lifted up about an inch or so and pulled out. However some have covers that snap in place. After you remove cover locate gas valve. It should have a control knob on top with markings for on, off, and pilot. Set control to pilot. Follow lines from gas valve to burner compartment, one goes to main burner one ,small copper colored line is the thermocouple, other line is the pilot. Turn thermostat down as far as it will go. Make sure gas supply valve in line to heater is on and then depress pilot control , when you have pilot control depressed have a match or other small flame source close to pilot assembly. If it lights then hold down on pilot control for a couple of mins. Slowly release pilot control and if it stays lit turn gas control to on. Turn thermostat up to call for heat and burner should light. If pilot doesn't stay lit when you release pilot control then try again holding pilot down longer. If it still won't stay lit then thermocouple will need replace. Good luck. Thanks

Nov 22, 2010 | Williams 6508732 Gas Heater

1 Answer

I have a ProCom Ventless Fireplace. LP Sometime


that shouldnt matter u probably have a runner tube where the gas runs from burner to burner sometimes they get clogged or spiders can build webs in them ur best bet is to turn the gas off take apart and clean tat should solve ur problem

Feb 26, 2010 | Procom ML300TBA Heater

1 Answer

Charmglow ventless gas fireplace burners won't ignite


is pilot flame on the thermopile good, pilot flame should cover the thermocouple and thermopile if unit has both

Jan 07, 2010 | Blue Flame Charmglow 30K BTU Propane Vent...

1 Answer

How do you shut down


the pilot light always stays on, its designed to allow your heater to turn on by itself without you needing to light a match every time. if the pilot light is burning you have nothing to worry about. its when the pilot light goes out that a small amount of gas leaks into the room. and by small i mean smaller than a hand held lighter... if you still want to shut the entire thing down you could turn off the gas line feeding the heater or possibly the whole house, otherwise the pilot light will stay on. as far as the actual heater turning off, thats probably controlled by some sort of thermostat somewhere. if you set the temp to very cold it should stay off. if that doesn't work then you may need a new thermostat.

Dec 31, 2009 | Vanguard International VN18B Infra-Red...

1 Answer

Pilot light goes out when I turn the the dial to "On"


Hi no thermocoples are made to be exchanged never come across that in 30 years of gas fitting

Nov 16, 2009 | Rinnai Desa Vent-Free Infrared Gas Heater:...

1 Answer

I have Legacy ventless propane heater 15,000btu.


Try to take pilot assembly apart and clean real good. This will work most of the time. If it does not work for you, you will need to replace the gas valve. It's expensive but I'm about positive that cleaning it will fix it. Gas burns dirty and after a couple seasons a scale builds up that causes this problem. It's pretty common and nothing to worry about after it's cleaned. Good luck.

Oct 17, 2009 | Dyna-Glo Heating & Cooling

1 Answer

Ventless gas wall heater. Pilot lights but wont stay lit.


The thermocouple may be worn out.
The thermocouple may have come loose from the valve.
The ODS pilot may be clogged with dust or lint and may need to be cleaned with air(less than 30psi)
The valve or regulator may be faulty.

Sep 30, 2009 | Desa International GWP20T GLOWARM Wall...

1 Answer

Pilotlight will not light, getting spark, but no propane.


make sure you have the gas valve knob on turned to pilot while pressing that down while pushing the spark it should light or it is tripped on a safety like rollout switch or oxygen depletion sensor if equipped which all ventless heaters are

May 12, 2009 | Dyna-Glo D-E37 Wall Mounted Panel Heater

1 Answer

Flame goes out Monessen Ventless fire place Model DLX24.


take a needle and put it into the end of the gas pilot hole. Wiggle it around in there, it just might have dust build up in there. Hope this helps ya.

Jan 17, 2009 | Stoves Monessen Variable Thermostat...

4 Answers

Comfort glo propane ventless heater won't light


I have several of these heaters in my rent houses and love them. The most problem I have is not being able to ignite the pilot with the user control igniter. Remove the screws that hold the front cover in place along with the front cover. Hold the pilot control down and ignite with a lighter. Keep the pilot engaged until thermocouple is warm enough to keep pilot gas flowing. If it will light this way then you need to blow out the pilot orifice. It seems that every year I have to go in after the summer season when the heater is off and clean the pilot/orifice lines with high pressure air. I believe spiders/bugs/dust block pilot orifice when it is not in use. You can also tell that orifice is blocked when you don't get a good blue pilot flame with pressure behind it allowing the flame to submerse the thermocouple. If the the thermocouple is not getting enought heat it will turn pilot gas off for safety reasons.

Nov 16, 2008 | Desa International GWP20T GLOWARM Wall...

Not finding what you are looking for?
Procom 10K BTU, Vent Free, 2 Plaque Infrared Space Heater, Natural Gas Infra-Red Patio Logo

720 people viewed this question

Ask a Question

Usually answered in minutes!

Top Procom Heating & Cooling Experts

paulcarew

Level 3 Expert

2364 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

john h

Level 3 Expert

8286 Answers

Are you a Procom Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...