Changing the battery

If your Tripp LIte Omni 1000 LCD display a fault icon and beeps after changing the battery, try the advice given by the buzzerman which worked perfect in this case:


1. Turn the UPS on. Press and hold the ON/OFF button for one second.

2. Run a Self-Test: Press and hold the MUTE/TEST button for two seconds (until beeps several times). The test will last 10 seconds. All LCD Display icons will be illuminated and the alarm will sound. At the end of this process the fault icon and the beeping turned off.

Posted on Sep 23, 2012

  • rachanee smoak
    rachanee smoak Oct 22, 2013

    How do you take the cover off to replace the battery it is not easy? Lisa

  • papaof2 Sep 04, 2014

    Two screws recessed deep in the back center. You need a #1 Phillips screwdriver with a 6 inch blade.

×

Ad

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 3 Answers

SOURCE: Tripp Lite OMNI 1000 LCD will not stay on

Turn UPS on: Press and hold the ON/OFF button for one second.
Run a Self-Test: Press and hold the MUTE/TEST button for two seconds (until alarm beeps several times).
The test will last 10 seconds. All LCD Display icons will be illuminated and the alarm will sound.
If the fault icon remains lit, the battery-supplied outlets are overloaded. Unplug powered devices until you remove the overload.
If the "Replace" icon remains lit and alarm continues to sound, the UPS batteries need to be recharged or replaced. Allow UPS to charge for 24 hours and repeat self-test.

Posted on Oct 19, 2010

  • 2 Answers

SOURCE: have several Tripp Lite Omniplus

A little research on the internet will answer your questions about battery replacements and cost. There are numerous sites selling batteries for your particular unit. Do a Google search on the battery type and see what you get. EBay is another possible source for batteries once you determine which size and what ratings you need for your replacements. The best way of determining how to replace the batteries is to open the UPS's case and carefully record how you remove the old batteries and then install the new ones in reverse order. You will have to open the UPS up to get at the batteries to determine type and specs so removal and re-installation should be easy from there.

Posted on May 01, 2011

  • 1 Answer

SOURCE: The LCD display no longer works on my Tripp Lite

Be aware.

My Tripp LIte Omni 1000 LCD almost caught on fire.
I had been experiencing a spike in my power bill to the tune of 1000 Watts an hour for everything running - 24x7. I started the survey of all my equipment; TV 162 Watts; Fridge 228, etc. but none of these devices are on all day and night. I finally mapped out all the outlets and lights and was about to begin the survey. Other than the flickering lights, one big clue was that my TL's lcd was displaying a spike in voltage DOWN to 95 or so, the relay would click, etc.

I decided to begin my survey and use my second TL to help me see which circuit was faulty. When I looked at the LCD, it was blank. I pushed the ON button and all the devices plugged in went OFF and then I saw smoke coming out of the back. I quickly unplugged everything and then watched my meter. When this UPS was plugged in, there was about 1000W used per hour; I monitored it for 10 hours; 400W were used (total).

So... not only was it a fire hazard, but it sucked up 900W or so an hour.

Posted on Jun 02, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How do I to open tripp-lite omni1000 LCD to change battery


Go to http://www.tripplite.com and enter model and search for battery installation instructions.

Feb 11, 2014 | Tripp Lite Tripplite Omniplus 1000 LCD UPS...

1 Answer

How do I open up the unit to replace the battery?


Hi Joe,

There is a door on the bottom or left hand side depending on orientation... this door opens revealing the battery inside.

Call me if you would like more assistance or pricing for a new battery -- 407.380.9200

Oct 19, 2013 | Tripp Lite Tripplite Omniplus 1000 LCD UPS...

1 Answer

Is not charging


Blank LCD on these models going out are usually due to the PCB connection.
I found units I've seen have broken traces or the pins mounted on the PCB have lost their connection to the traces...
this is the ribbon cable from the display to the main UPS PCB...

Oct 03, 2012 | Tripp Lite Tripplite Omniplus 1000 LCD UPS...

1 Answer

Tripp.lite ups fault displayed and beeping


My Tripp Lite was showing a fault this morning for no logical reason, ran this self test as suggested and all cleared. Thanks.

Apr 24, 2012 | Tripp Lite Tripplite Omniplus 1000 LCD UPS...

1 Answer

Display will not come on plugged in or not


The UPS needs to have a good DC Buss for it to work. Before you buy the new battery disconnect the battery & unplug it from the wall. Push the on button to reset the logic. You may see the display flash breifly. Install the new battery. Then plug in the UPS and turn it on and enjoy

Oct 20, 2011 | Tripp Lite Tripplite Omniplus 1000 LCD UPS...

1 Answer

Have several Tripp Lite Omniplus 1000LCD UPS battery backups that are no longer working. They are several years old. I assume that these units need new batteries. Where do I get battery replacements,...


A little research on the internet will answer your questions about battery replacements and cost. There are numerous sites selling batteries for your particular unit. Do a Google search on the battery type and see what you get. EBay is another possible source for batteries once you determine which size and what ratings you need for your replacements. The best way of determining how to replace the batteries is to open the UPS's case and carefully record how you remove the old batteries and then install the new ones in reverse order. You will have to open the UPS up to get at the batteries to determine type and specs so removal and re-installation should be easy from there.

Apr 30, 2011 | Tripp Lite Tripplite Omniplus 1000 LCD UPS...

1 Answer

The LCD display no longer works on my Tripp Lite Omni 1000 LCD. Also, half of the power outlets on the back of the unit no longer work.


Be aware.

My Tripp LIte Omni 1000 LCD almost caught on fire.
I had been experiencing a spike in my power bill to the tune of 1000 Watts an hour for everything running - 24x7. I started the survey of all my equipment; TV 162 Watts; Fridge 228, etc. but none of these devices are on all day and night. I finally mapped out all the outlets and lights and was about to begin the survey. Other than the flickering lights, one big clue was that my TL's lcd was displaying a spike in voltage DOWN to 95 or so, the relay would click, etc.

I decided to begin my survey and use my second TL to help me see which circuit was faulty. When I looked at the LCD, it was blank. I pushed the ON button and all the devices plugged in went OFF and then I saw smoke coming out of the back. I quickly unplugged everything and then watched my meter. When this UPS was plugged in, there was about 1000W used per hour; I monitored it for 10 hours; 400W were used (total).

So... not only was it a fire hazard, but it sucked up 900W or so an hour.

Nov 28, 2010 | Tripp Lite (OMNI1000LCD) UPS System

1 Answer

The battery backup outlets are not working


You most likely need a new battery. Remove the battery and test it. If you dont have the ability to test it take it to an interstate battery store, or any similar battery store and ask them to test it for you.

Dec 07, 2009 | Tripp Lite OMNIVS1000 UPS System

Not finding what you are looking for?
Tripp Lite Tripplite Omniplus 1000 LCD UPS System Logo

1,496 people viewed this question

Ask a Question

Usually answered in minutes!

Top Tripp Lite Computers & Internet Experts

Cindy Wells

Level 3 Expert

5124 Answers

SHIVAJI YADAV
SHIVAJI YADAV

Level 2 Expert

188 Answers

240cpa

Level 3 Expert

548 Answers

Are you a Tripp Lite Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...