Question about Accelevision DVD Player with Built-in TV Tuner (DVD1008) Car Video Player

Open Question

DVD player won't turn on.

Hi, i have a Accelevision DVD-9520A that i just installed in my van. the power is off the ignition and when i turn it on the led's flash but it does not respond to the power button (turn on). i checked the power and it is ok at the plug. any suggestions? ironside

Posted by on

Ad

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
gopakumarg43
  • 75786 Answers

SOURCE: i need to know the

Hello
There is a built in protection fuse inside your DVD system, and there is no need to connect a fuse external. Anyway it is wise to connect a 4Amps 250VDC Slow blow type fuse and it will act as an extra protection. This is a glass cartridge type fuse, and can be bought from most of the electronc sparepart dealers. OK.

Posted on Jun 03, 2011

Ad
kenw392
  • 2226 Answers

SOURCE: Information needed on Accelevision AXFA11W. I need

Usually fuses for those type of units are 7.5 - 10 amps.

Posted on Jun 03, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Goodman GMP 125-5 furnace. It had a 3 light code i replaced the presure switch now it is giving me a 1 light code please help


A sampling of various failure codes on a furnace:

Read one LED flash that stays on continuously to mean your furnace has no signal coming from the thermostat and will not operate. Turn the power off and check the thermostat for improper settings or connections.

Interpret one LED flash that blinks on and off to mean your furnace has locked out because it could not ignite after three tries, and must be reset. Interrupt power to your furnace for 20 seconds or lower the thermostat so your furnace does not try to heat, then reset the thermostat to the previous setting. After one hour of lockout, your furnace will automatically reset itself and try to operate as usual.

Decipher two LED flashes to mean the draft blower is not working, or your furnace has a short in the pressure switch circuit. Turn off the furnace power and repair a short or replace the pressure switch.


Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection. Also, look for blockages in the flue, and tighten any loose wiring.

Translate four LED flashes to mean your furnace has a primary limit circuit open, possibly from loose wiring or blocked filters. Check and clean filters, tighten wiring and check the flue for blockages.

Interpret five LED flashes to mean your furnace senses a flame without a call for heat. This could be from a gas valve closing slowly or a burner flame lingering.



Read seven LED flashes as a warning of a low flame sense microamp signal. This could happen with a coated flame sensor or a lazy flame from poor gas pressure. Turn off the power and adjust the gas pressure according to the information on the rating plate.



See eight LED flashes as meaning an igniter circuit problem due to a bad igniter or an igniter connected improperly. Replace the bad igniter or check the ground wiring, making necessary corrections.



Decipher nine LED flashes to mean the high-stage pressure switch circuit will not close during a high-stage-induced draft blower operation. Your furnace may have a pinched or blocked pressure switch hose, a blocked flue or loose wiring.

Read continuous flashing on the LED to mean your furnace has a reversed polarity of 115 volts. Turn off the power and correct the wiring polarity after reviewing the wiring diagram.
themobilian_3094.jpg

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Oct 28, 2011 | Goodman Heating & Cooling

1 Answer

I have goodman GMP series furance the furnance and gas comes on and fires up then goes out flame sensor is good what else could be wrong


Improper ground from control to burner.
Incorrect electrical wiring, check polarity.
Tubing partially clogged between inducer and proving switch.

A sampling of various failure codes on a furnace:

Read one LED flash that stays on continuously to mean your furnace has no signal coming from the thermostat and will not operate. Turn the power off and check the thermostat for improper settings or connections.

Interpret one LED flash that blinks on and off to mean your furnace has locked out because it could not ignite after three tries, and must be reset. Interrupt power to your furnace for 20 seconds or lower the thermostat so your furnace does not try to heat, then reset the thermostat to the previous setting. After one hour of lockout, your furnace will automatically reset itself and try to operate as usual.

Decipher two LED flashes to mean the draft blower is not working, or your furnace has a short in the pressure switch circuit. Turn off the furnace power and repair a short or replace the pressure switch.


Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection. Also, look for blockages in the flue, and tighten any loose wiring.

Translate four LED flashes to mean your furnace has a primary limit circuit open, possibly from loose wiring or blocked filters. Check and clean filters, tighten wiring and check the flue for blockages.

Interpret five LED flashes to mean your furnace senses a flame without a call for heat. This could be from a gas valve closing slowly or a burner flame lingering.



Read seven LED flashes as a warning of a low flame sense microamp signal. This could happen with a coated flame sensor or a lazy flame from poor gas pressure. Turn off the power and adjust the gas pressure according to the information on the rating plate.



See eight LED flashes as meaning an igniter circuit problem due to a bad igniter or an igniter connected improperly. Replace the bad igniter or check the ground wiring, making necessary corrections.



Decipher nine LED flashes to mean the high-stage pressure switch circuit will not close during a high-stage-induced draft blower operation. Your furnace may have a pinched or blocked pressure switch hose, a blocked flue or loose wiring.

Read continuous flashing on the LED to mean your furnace has a reversed polarity of 115 volts. Turn off the power and correct the wiring polarity after reviewing the wiring diagram.

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Oct 18, 2011 | Goodman GMS90703BXA Heater

1 Answer

Suddenly not working im not sure if there even is a pilot to be lit


Goodman have troubleshooting idiot lights on the board. Look for flashes and count em.
The flash explanations are printed on the backside of the blower cover on most models.
A sampling of various failure codes on a furnace:

Read one LED flash that stays on continuously to mean your furnace has no signal coming from the thermostat and will not operate. Turn the power off and check the thermostat for improper settings or connections.

Interpret one LED flash that blinks on and off to mean your furnace has locked out because it could not ignite after three tries, and must be reset. Interrupt power to your furnace for 20 seconds or lower the thermostat so your furnace does not try to heat, then reset the thermostat to the previous setting. After one hour of lockout, your furnace will automatically reset itself and try to operate as usual.

Decipher two LED flashes to mean the draft blower is not working, or your furnace has a short in the pressure switch circuit. Turn off the furnace power and repair a short or replace the pressure switch.


Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection. Also, look for blockages in the flue, and tighten any loose wiring.

Translate four LED flashes to mean your furnace has a primary limit circuit open, possibly from loose wiring or blocked filters. Check and clean filters, tighten wiring and check the flue for blockages.

Interpret five LED flashes to mean your furnace senses a flame without a call for heat. This could be from a gas valve closing slowly or a burner flame lingering.



Read seven LED flashes as a warning of a low flame sense microamp signal. This could happen with a coated flame sensor or a lazy flame from poor gas pressure. Turn off the power and adjust the gas pressure according to the information on the rating plate.



See eight LED flashes as meaning an igniter circuit problem due to a bad igniter or an igniter connected improperly. Replace the bad igniter or check the ground wiring, making necessary corrections.



Decipher nine LED flashes to mean the high-stage pressure switch circuit will not close during a high-stage-induced draft blower operation. Your furnace may have a pinched or blocked pressure switch hose, a blocked flue or loose wiring.

Read continuous flashing on the LED to mean your furnace has a reversed polarity of 115 volts. Turn off the power and correct the wiring polarity after reviewing the wiring diagram.

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Feb 03, 2011 | Goodman Heating & Cooling

1 Answer

I have a Sony BDP S370 and I would like to make it region free for my DVDs.


hi,
u can make your dvd for region free DVD play back. but for that you have to purchase an universal remote (ONE FOR ALL URC-7950). through this remote only you can make player DVD region free.
first of all u have to set( program) the remote for the same purpose.

Full procedure for the OneForAll URC-7950 remote is as follows:(preparing remote)

1. Press DVD
2. Hold the magic button until the Power key flashes twice.
3. Press 0533

4. Hold the magic button until the red led flashes twice.
5. Press 994
6. Press Magic key (don't hold)
7. Press 00189
8. Press 1 ( this sets it to key 1 - it flashes twice, if not repeat steps 4 to 8 )

9. Hold the magic button until the red led flashes twice.
10. Press 994
11. Press Magic Key (don't hold)
12. Press 00255
13. Press 2 ( this sets it to key 2 - it flashes twice )

14. Hold the magic button until the red led flashes twice.
15. Press 994
16. Press Magic Key (don't hold)
17. Press 00095
18. Press 3 ( this sets it to key 3 - it flashes twice )

19. Hold the magic button until the red led flashes twice.
20. Press 994
21. Press Magic Key (don't hold)
22. Press 00221
23. Press 4 ( this sets it to key 4 - it flashes twice )

24. Hold the magic button until the red led flashes twice.
25. Press 994
26. Press Magic Key (don't hold)
27. Press 00079
28. Press 5 ( this sets it to key 5 - it flashes twice )

The remote is now programmed and ready to use, to make the BDP-S370 region free

1. Use the remote that came with the player to bring the player out of standby, make sure there isn't a disc in it.
2. Press 1, 2, 3, 4, 5 on the OneForAll URC-7950 remote. The power light will start flashing. (blue middle light)
3. Put the player back into standby with the Sony remote.
4. Next time you turn on the player it will be region free for DVD playback.
OK

Jan 13, 2011 | Sony BDPS370 BluRay Player

1 Answer

My central heating is on lockout and the burner is with red light


A sampling of various codes on a furnace

Read one LED flash that stays on continuously to mean your furnace has no signal coming from the thermostat and will not operate. Turn the power off and check the thermostat for improper settings or connections.

Interpret one LED flash that blinks on and off to mean your furnace has locked out because it could not ignite after three tries, and must be reset. Interrupt power to your furnace for 20 seconds or lower the thermostat so your furnace does not try to heat, then reset the thermostat to the previous setting. After one hour of lockout, your furnace will automatically reset itself and try to operate as usual.

Decipher two LED flashes to mean the draft blower is not working, or your furnace has a short in the pressure switch circuit. Turn off the furnace power and repair a short or replace the pressure switch.


Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection. Also, look for blockages in the flue, and tighten any loose wiring.

Translate four LED flashes to mean your furnace has a primary limit circuit open, possibly from loose wiring or blocked filters. Check and clean filters, tighten wiring and check the flue for blockages.

Interpret five LED flashes to mean your Goodman furnace senses a flame without a call for heat. This could be from a gas valve closing slowly or a burner flame lingering.



Read seven LED flashes as a warning of a low flame sense microamp signal. This could happen with a coated flame sensor or a lazy flame from poor gas pressure. Turn off the power and adjust the gas pressure according to the information on the rating plate.



See eight LED flashes as meaning an igniter circuit problem due to a bad igniter or an igniter connected improperly. Replace the bad igniter or check the ground wiring, making necessary corrections.



Decipher nine LED flashes to mean the high-stage pressure switch circuit will not close during a high-stage-induced draft blower operation. Your furnace may have a pinched or blocked pressure switch hose, a blocked flue or loose wiring.

Read continuous flashing on the LED to mean your furnace has a reversed polarity of 115 volts. Turn off the power and correct the wiring polarity after reviewing the wiring diagram.

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Dec 02, 2010 | Heating & Cooling

1 Answer

I need to manually program my universal vizio remote


Hi,

1. Manually turn on the VCR/DVD/Cable set top box.

2. Press the VCR/DVD/Cable set top box button on the remote control.

3. Press and hold the SETUP button until the LED LIGHT flashes twice.

4. Enter the codes using the Number Buttons. If the code is accepted, the LED flashes twice after the last digit is entered.

If the LED does not flash twice, repeat Steps 2 through 4 with the next code listed for the component and
manufacturer.

5. Point the remote control at the VCR and press the POWER button. The VCR/DVD/Cable set top box will turn off.
6.Your are done.

Thanx

Jul 23, 2010 | Vizio VR2 Remote Control

1 Answer

We just bought an Accelevision ZDP15 Super Compact Car DVD Player. The problem is it didn't come with a manual and it looks like the previous owner messed up some of the wiring. It just looks cheezy, some...


Well not saying this is the case for this radio but they usualy come with some pretty standard wiring colors. I have listed the most common colors and there usual function. Again this is a pretty general list and may not be 100% accurate for your application. Hope it helps.



Stereo: Memory (+12v Constant) Orange Ignition (+12v Switched) Red Ground (-) Black Illumination Yellow Phone Mute Yellow/Black Power Antenna Blue

Speakrs:
Right Front (+) Gray Right Front (-) Gray/Black Left Front (+) Green Left Front (-) Green/Black Right Rear (+) Gray/Red Right Rear (-) Black/Gray Left Rear (+) Green/Red Left Rear (-) Black/Green

Mar 20, 2010 | Audiovox VM9512 Car DVD Player

2 Answers

Immobiliser is not turning off and not allowing the engine to start


is it a stick immobiliser?
If your vehicle does not start and the LED continues to flash while the Ignition is 'ON', this means that the Immobiliser system has not recognised the transponder stick.
Simply turn the Ignition 'OFF' then back 'ON' again. If the Status LED continues to flash, move the transponder stick closer to the key barrel until the LED stops flashing and turns 'OFF'.
If the transponder stick on the key ring does not disarm the immobiliser or the
transponder stick is misplaced, you can override the system by entering a 5-digit override number. Each vehicle has a unique 5-digit override number. This number is recorded on the
customer’s owner’s manual. If the customer loses their owner’s manual / override number, the number can be found by locating the vehicle’s Daewoo Stock Number (D.S.N). The customers override number is the last 5 digits of their D.S.N.
9748811.jpg
Overriding the system using the example 5 digit code 2,1,0,6,2
Important Note: 10 flashes of the Status LED represent the number ‘0’.
1. Remove the Transponder from the Key Ring.
2. With the system armed (LED flashing slowly) Turn the ignition ON/OFF 5 times, with the final position being off.
3. The LED will turn solid red for 2 seconds and then begin to flash.
4. When the LED flashes twice (2), turn the ignition ON. (number 2 was entered)
5. Turn the ignition OFF and wait for the LED to flash once (1) and then turn the ignition ON. (number 1 was entered)
6. Turn the ignition OFF and wait for the LED to flash ten (10) times and then turn the ignition ON. (number 0 was entered)
7. Turn the ignition OFF and wait for the LED to flash six (6) times and then turn the ignition ON. (number 6 was entered)
8. Turn the ignition OFF and wait for the LED to twice (2) and then turn the ignition ON.(number 2 was entered) The LED will turn solid red, which means the system is now overridden and the vehicle can be started. If an incorrect number is entered in, wait 11 flashes then start the procedure again.
NOTE: This is a one-event override. Once the ignition is turned off, the vehicle will passively immobilise after 30 seconds. If your 5 digit override number does not override the system, the chances are that you entered the wrong number. If this is the case, you’ll need to re-enter the override number
and try it again.

Jul 13, 2009 | 1999 Daewoo Lanos

1 Answer

Accelevision 9520


you need to go to am fm, change from tuner to Aux, thats how it works in my limo

Mar 17, 2008 | Accele DVD9520

Not finding what you are looking for?
Car Audio & Video Logo

Related Topics:

73 people viewed this question

Ask a Question

Usually answered in minutes!

Top Accele Car Audio & Video Experts

xxxxxx xxx

Level 3 Expert

4981 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Marvin
Marvin

Level 3 Expert

81423 Answers

Are you an Accele Car Audio and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...