Question about Maytag SkyBox MBV1976A Beverage Dispenser

2 Answers

Skybox Hi there - I have a Maytag Skybox that has stopped cooling - the "repair man" came and said it was the relay overload and can't be fixed - he said it's against policy to give out the part number for the item. I see you've helped a lot of people with this problem - any chance you can eamil the manual to me and if you happen to know the part number for the relay - I really do apprectiate any help. Please email to: daa12@att.net or if that is a problem : DAndreoli@CAinc.com (my work) thank you thank you thank you

Posted by on

  • 2 more comments 
  • nickels6904 Oct 26, 2008

    dispenser and lights work, does not cool.

  • tada12 Oct 31, 2008

    I went to the web site you suggested, entered the info and unfortunately there is no listing for the starter relay or starter relay overload. Any other suggestions? Thanks in advance for your help

  • Kadl Nov 06, 2008

    The Skybox has stopped cooling. There was some water below the unit when we noticed it had stopped cooling. Is there anything we can do prior to calling a repair person? We have no manual.



    Thanks so much in advance---

  • VINNYVUSMC Nov 06, 2008

    I TOO HAVE A MAYTAG SKY BOX FOR ABOUT 5 YEARS NOW. THE COOLING SYSTEM JUST WENT A FEW MONTHS AGO. I HAD A MAYTAG REPAIR MAN LOOK AT IT AND HE SAID THERE HAS BEEN MANY PROBLEMS WITH THE SKYBOX AND THEY DON'T CARRY THEM ANY MORE. WHAT CAN I DO TO FIX THE COOLING SYSTEM

×

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

I have a skybox as well and all of a sudden it has stopped cooling. What are your suggestions on how to trouble shoot. Especially if you've never worked on a appliance like this before.

thanks

Posted on Oct 31, 2008

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 770 Answers

Go to www.apdepot.com and enter your model number under Brand :Maytag you will see a parts breakdown and you can buy it online

Posted on Oct 20, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

3 Answers

Maytag Skybox has stopped cooling


the whirlpool part is the oem part and is the best part for your repair it should replace wire for wire and require very little instruction. the 3-n-1 will cause premature failure of the compressor and is not recommended. As far as I know there really isnt a service manual available for the skybox. It was a very limited production product that didnt stay available for very long. thnaks Peyton

Mar 02, 2009 | Maytag SkyBox MBV1976A Beverage Dispenser

1 Answer

Maytag skybox stopped cooling Skybox stopped cooling. Sounds like the relay will kick on briefly and then click off. Everything else works. I took the back panel off and could hear the relay clicking on...


The relay on your box is damaged.. You have to get it replaced.. Not to be tried by a novice but if you have some experience in electronics it can be fixed by you. The relay costs around 75$. Good luck!

Mar 26, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

1 Answer

Maytag Skybox not cooling


sounds like compressor relay --- if the fan and compressor come on and then shut off after about 5-10 seconds -- its the relay --- sometimes you have to also replace the transformer and capacitor on the opposite side of the unit --- all items are accesible from the back of the unit

Jan 23, 2009 | Maytag SkyBox MBV1976A Beverage Dispenser

1 Answer

Maytag skybox start relay is bad


you need to change the overload relay ---- there is a company called appliancezone.com

they sell the overload relay unit with all the parts for $26.00

email me back if you cant find it---- put in the model # for the skybox unit and you will see the item

item # 4387835

this is the problem -- if this relay goes bad the compressor will stay on and not supply cold air to the unit ----

Dec 16, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

1 Answer

Maytag Skybox


good to hear another skybox lives...thanks for the kind words. alex

Dec 10, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

1 Answer

SkyBox Manual


if its not cooling -- is it about 2-3 years old -- the relay overload switch had gone bad

its mounted on the side of the compressor behind the small black cover

go to appliancezone.com

part # 4387835

cost $ 26.00

Nov 27, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

3 Answers

Skybox by Maytag not cooling


our skybox just stopped cooling. i think the compressor kicks on but wont cool. can somebody please help me! thanks barbie

Jul 01, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

4 Answers

Maytag SkyBox


For the soda name tags, I pulled logos off the internet and printed them the correct size on 20-pound paper. Different paper gives different translucence, so you might have to experiment to get the right amount of light coming through.
PS: thanks for the part no. on the relay

Apr 21, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

16 Answers

Maytag skybox stopped cooling


I just replaced my in-pieces starter relay and thermal swich with a Whirlpool 4387535 kit. My Skybox has been working fine ever since.

Note I had the same symptoms as other posts of the compressor turning on/off continuously (but no cooling)...I believe what was happening is that the starter relay would allow current to flow to initially start the compressor, but would never stop providing current to it after it had already started (as it should) thus in a few seconds the thermal switch would sense this and trip / remove power to the compressor...then this cycle would start all over once the thermal switch cooled down again and let power back to the compressor...

This kit is evidently the newer style of what is on the original Skybox compressors (functionally speaking)...the new starter relay looks and installs like the old one, but the thermal switch is different and you need to remove the old one (follow the black wire on the top post of the compressor back a little to a small black round thing with a flexible metal piece inside). The good news is that once you remove it, it already has the correct spade lug on the wire to plug directly into the new thermal switch which sits right on the top lug of the compressor above the starter relay.

Note I'm not a service tech, just a Skybox owner who was/is tired of Maytag disowning this product and calling it a "throwaway" when any part of it stops working (and all local authorized service centers laughing when asked to repair one).

Continuing on with my rant a little, I also see other posts on the internet which also state "throwaway" when you actually have a bad compressor because you can't get direct replacements anymore - my friend who does AC work on the side said he most certainly could put another compressor in there from probably just about any other mini-fridge...he just noted that it is a small place to do it so the replacement compressor form factor will have to be considered. He stated you may get a little more or less cooling efficieny but who cares if you really want to keep your machine working that you can't buy anymore (nor get a close alternative).

Mar 13, 2008 | Maytag SkyBox MBV1976A Beverage Dispenser

Not finding what you are looking for?
Maytag SkyBox MBV1976A Beverage Dispenser Logo

385 people viewed this question

Ask a Question

Usually answered in minutes!

Top Maytag Vending Machines Experts

John Tripp
John Tripp

Level 3 Expert

4630 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3053 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Are you a Maytag Vending Machine Expert? Answer questions, earn points and help others