New installed W.Bosch Greenstar 30CDi with DT20RF programmer. Have been getting intermittent cut out of heating when in progress as indicated on the programmer display by flashing green heating led and flashing CH & RF receiving icon on lcd disply. The heating ceases and resumes eventually on its own accord.The thermostat is still requiring heating according to its display. The thermostat batteries are fine ,there is no error messages on thermostat. Any ideas?

Posted by on

  • 3 more comments 
  • fixya346 Nov 19, 2008

    My Worcester Bosch Greenstar 30CDi with DT20RF programmer was installed in April and has same symptoms except the only thing flashing is RF receiving icon on lcd disply.

  • lambertsj Dec 12, 2008

    my dt20rf has just started doing the same thing (installed april) i have noidea whats causing it can the radio frequency be interfered with by anything?

  • philjames Dec 20, 2008

    Unit was installed earlier this week. Exactly the same problem is occurring. Heating comes on and off at apparently random times.

  • tez100 Dec 22, 2008

    Same as other posts...unit has been installed about 10 months...replaced batteries...cant setup RF link.

  • xeejay Mar 14, 2009

    The Heating does not function until the OK button is pressed and then it will not allow selection of timer mode for about ten to twenty minutes, it eventually reverts to timer. The antenna is flashing during this time, could it be interference form our computer network modem which is quite close by?

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

One of my customers had the same fault recently. We tryed to reset the radio connection but, the appliance still did not respond.
The receiver was disconnected for the evening to prove boiler and system functionality which was ok.
Next day we installed new receiver & followed set up. customer has had no symptoms for 2 mnths.
Hope this helps.

Posted on Apr 21, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Need help understanding how to wire a new programmeable thermostat. I currently have a White Rodgers 1F73 model (non-programmeable) connected. I am confused with the instructions on how to connect the...


the black wire is your common wire, you need to program your thermostat, in the advance mode, to tell the t-stat if your heat pump reversing valve is energized on cooling or heating, is the orange wire connected to your t-stat.= w2/o/b

Dec 20, 2014 | Honeywell Air Conditioners

1 Answer

I just replaced my manual thermostat with a programmable one. The problem is the old one was positioned under a ceiling vent. Now the programmable one cause the heat to cut on and off before the room...


Move the wall thermostat to a new location away from the ceiling fan or stop using the ceiling fan. Also, try running the ceiling fan in reverse (counter clockwise when you're looking up at the fan blades) on slowest speed. That might solve the problem, too.

Please let e know is that helps.

Rich

Feb 07, 2011 | Air Conditioners

1 Answer

Good morning. I have a Bosch Worcester Greenstar 28i Junior. As the fan statrs up the mains power trips out. Is it the fan at fault or could there be another/different fault.


it could be the fan or the pump best thing to do is disconnect fan and start it up and if it does not blow that the problem

Feb 04, 2011 | Air Conditioners

1 Answer

Ferroli optimax he 31c. brand new system will only heat 3 of 8 rads. boiler on 90c will only burn for 15sec then D2 shows and it cuts out. Why??


it is either your pump is not running or blocked [ debris from installation ect ] or your diverter valve is stuck partially open allowing a little water to pass into the heating system [ usually first rads on system ] it runs for a short while and cuts out because your overheat stat is kicking in because of poor circulation [ it is only running around the primarys in the boiler where it quickly reaches the over heat limit ] temp tends to rise approx 1 deg per second a clear indication of circulation problems.
solution GET RID OF THE FERROLI

Dec 22, 2010 | Air Conditioners

1 Answer

Greenstar 30CDi conventional condensing boiler and the temperature is fluctuating rapidly and repeatedly between 37 and 63 degrees. It is set on 4 so just above 60 sounds correct according to manual....


It sounds like you have air in the system, Turn Boiler Off keep pump running and try to find a spot where you can bleed the air out.

If you dont have an automatic water fill installed then
you will have to add water by hand

Feb 14, 2010 | Air Conditioners

1 Answer

Carrier Infinity Control Programming Issue


Open the flap, and press and hold the advanced button for 10 sec. you will be in the Installer setup screen. scroll down to the setup subfolder and select thermostat and it will be in there.

Feb 27, 2009 | Carrier Air Conditioners

1 Answer

Bosch greenstar 30 CDi - no central heating or hot water!


it sounds like the system was not cleaned properly when the new boiler was fitted. all new boilers need to have the pipework flushed to remove any debris scale sludge and flux from the system. this is now usually done by a power flush which is basically a big pump mounted on a big bucket and it washes the dirt out of the pipework and collects in the bucket. if this is not done the dirt will block up the small passages in the heat exchanger. i suggest the system is cleaned flush and the heat exchanger changed to help protect the boiler a filter should be fitted (for example a magna clean) if the company who installed the boiler is corgi registered then they are liable for the damages. call corgi for advice.

Jan 04, 2009 | Air Conditioners

1 Answer

My Worcester Bosch Greenstar Combi boiler digital display has started flashing the temperature then two half-rectangles alternately ... it is not heating the radiators to full capacity - any ideas?


just had same problem.  this apprently happens if the power supply has been interrupted or you switch the power on and off.
• The boiler runs for 15 minutes at minimum heat output to fill the condensate trap, the display (K) alternates between -II-” and the boiler flow temperature. This occurs every time the mains supply has been interrupted.

Nov 02, 2008 | Air Conditioners

1 Answer

Domestic heating system


Contacted supplier and they have arranged a visit.
Thanks

Sep 14, 2008 | Air Conditioners

1 Answer

Thechnical data of greenstar 15 Ri worcester


Greenstar 15Ri Technical data table Technical data Title Value Height (mm) 600mm Width (mm) 390mm Depth (mm) 270mm Weight 22.6kg Output to central heating and domestic hot water 5 - 15kW (17,060 - 51,180Btu/hr) SEDBUK Value/band 90.1%/Band A Solar compatible Yes Maximum horizontal flue (100mm ø) 4,600mm (inc. terminal) Maximum vertical flue (100mm ø) 6,400mm (inc. terminal) Maximum horizontal flue (125mm ø) 13,000mm (inc terminal) Maximum vertical flue (125mm ø) 15,000mm (inc. terminal) Gas connection 22mm compression Heating flow and return connections 22mm compression Maximum flow temperature 82ºC (180ºF) Primary water content 1.1 litres NOx classification Class 5 Noise output level 42.7 dB(A)
Hope this is what you wanted..

Let me know if you need any thing els.....

Sep 10, 2008 | Air Conditioners

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

1,358 people viewed this question

Ask a Question

Usually answered in minutes!

Top Air Conditioners Experts

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Bill Long

Level 3 Expert

577 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Are you an Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...