Question about Epson AcuLaser C900 Printer

1 Answer

Error 6022 Thanks for your advice but the problem is not yet solved. As I said, I've already checked the photoconductor before posting my problem and I don't see any foreign material on it. Now it's worse, I'm getting an error 6022. Previous posting: There is a rectangular mark (the size of an address label) on each pageI'm printing. Before that, I did print some self-adhesive addresslabels. My hunch is that a label is possibly stuck somewhere in theprinter. I called Epson and they told me to check the photoconductorand transfer unit but I didn't find anything there. I followed all thepaper jam instructions but still no luck. Do you have any idea how Ican solve this problem? Thanks so much for your valuable assistance!

Posted by on

1 Answer

I had the same problem just today, i disaasembled the printer got out the transfer built and cleaned it, unscrewed the speed sensor and cleaned it , and its now working perfectly again,.

Posted on Nov 09, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Error Code


Hi James,
I've didn't noticed that you've posted a new question through another thread. Please reply only to your original question so that I can saw right away....
I will not informed once you create a new question.
"34" is an error code for lamp abnormality.
Since you've already replaced the lamp, it is not the suspect now. You must check the condition of the ballast board first. Please let me know if you can troubleshoot the ballast board through series of test using the multimeter.

Jan 03, 2012 | Televison & Video

1 Answer

Printer will not print, error message photoconductor kit error end of life problem, even though kit has been changed


Most of the photoconductors reset automatically through some sort of electrical trip. If this is already broken when it comes in, it of course will not reset. It will still work fine but you need to manually reset the count. Look up in the manual on how to do this or provide what type of printer it is.

Dec 08, 2010 | Computers & Internet

1 Answer

We are receiving the error message "84 oc life exhausted". What can we do to solve?


84 PC Life Exhausted indicates that the photoconductor unit has reached its functional life. The photoconductor kit will need to be replaced. The printer will not function so long as the Exhausted message remains on the display. The only way to clear the message is to install a new photoconductor. After replacing the photoconductor unit, you need to manually reset the pc page counter as well. Thank you for choosing Lexmark.

Sep 01, 2010 | Lexmark Optra SC 1275 Laser Printer

2 Answers

I have a new photoconductor unit in my epson CX11N aculaser printer and now it is printing anything in colour with a white stripe down the left hand side about 4cm in


Hi

Try taking out all toners and reinstall them. Turn on unit, without Photoconductor, wait till you get error install photoconductor. Insert photoconductor and try printing again.

Hope this helps

Mar 26, 2010 | Epson AcuLaser CX11N All-In-One Printer

2 Answers

Error service req E511, all lights flashing


Possible parts that caused the error

1 Photoconductor Unit 2 SENSOR TR-0
3 HARNESS-ASSY XERO 4 MOTOR ASSY P/R
5 HARNESS ASSY MAIN 6 PWBA MCU
7 LV/HVPS

Dec 28, 2009 | Epson ACULASER CX11NF All-In-One Printer

1 Answer

SC366 on CL4000DN


I just came across this post, you've likely solved it by now; However it is a "Toner density" error related to your cyan photoconductor. It is a defective connector. Replacing the cyan photoconductor should solve problem.

Feb 05, 2009 | Ricoh CL4000DN Laser Printer

3 Answers

Epson Aculaser C1100 Printer suddenly stopped printing


Hi,

To my knowledge Error Code E511 refers to photoconductor and/or its associated components. It is possible that:
  • the photoconductor requires a bit of cleaning and to be reseated snugly;
  • the black rubber conveyor (transfer) belt inside the photoconductor moved away from its path;
  • the silver square reflector on the transfer belt needs cleaning;
Hope this be of initial help/idea. Pls post back how things turned up or should you need additional information.

Good luck and kind regards. Thank you for using FixYa.

Aug 18, 2008 | Epson Aculaser C1100 Printer

1 Answer

Photoconductor and error 537


Hi,

Perhaps a copy of the parts diagram and/or the multi part service manual might be of more help.

Hope this be of initial help/idea. Pls post back how things turned up or should you need additional information.

Good luck and kind regards. Thank you for using FixYa.

Aug 14, 2008 | Epson Aculaser C1100 Printer

4 Answers

Epson CX11NF Error Message Service Req E511


This is from the service manual
Service Req E511
�� Possible parts that caused the error�� Troubleshooting
�� Photoconductor Unit �� SENSOR TR-0
�� HARNESS-ASSY XERO �� MOTOR ASSY P/R
�� HARNESS ASSY MAIN �� PWBA MCU�� LV/HVPSStep Check Yes No
1 Check of Photoconductor Unit attachment
Re-attach Photoconductor Unit.
Does the error recur when the power is turned
ON?
Go to Step [2]. End of
procedure
2 Operation check of Photoconductor Unit
Is the Drum of Photoconductor Unit rotating?
Go to Step [3]. Go to Step [10].
3 Check for dirt on silver seal on Belt in
Photoconductor Unit
Remove Photoconductor Unit.
Turn gear of Photoconductor Unit until silver
seal attached to Belt can be seen.
Is silver seal dirty?
Replace
Photoconductor
Unit.
Go to Step [4].
4 Check of SENSOR TR-0 (TR0 Sensor)
attachment
Remove Photoconductor Unit.
Is SENSOR TR-0 attached securely?
Go to Step [5]. Re-attach
the SENSOR
TR-0, and go to
step [5].
5 Check of dirt and foreign bodies on surface
of SENSOR TR-0
Remove Photoconductor Unit.
Are there any dirt or foreign bodies on the
SENSOR TR-0 surface?
Clean to remove
any dirt or
foreign bodies,
and go to step
[6].
Go to Step [7].
6 Does the error recur when the power is
turned ON?
Go to Step [7]. End of
procedure
7 Operation check of SENSOR TR-0
Remove Photoconductor Unit.
The voltage of P416-2 ↔ P416-3 on PWBA
MCU is 5 VDC when silver paper or other
reflective object comes close to the sensing
area of SENSOR TR-0, and is 0 VDC when
the object is released?
Replace PWBA
MCU. (p.404)
Go to Step [8].
8 Check of 5 VDC power supply to SENSOR
TR-0
The voltage of P416-1 ↔ P416-3 on PWBA
MCU is 5 VDC?
Go to Step [9]. Go to Step [14].
9 Continuity check of HARNESS-ASSY XERO
Disconnect the P/J416 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J416-1 ↔ J108-3
J416-2 ↔ J108-2
J416-3 ↔ J108-1
Replace
SENSOR TR-0.
(p.361)
Replace
HARNESSASSY
XERO.
10 Check after replacement of MOTOR ASSY
P/R
Replace MOTOR ASSY P/R. (p.398)
Does the error recur when the power is turned
ON?
Go to Step [11]. End of
procedure
11 24 VDC power supply check to MOTOR
ASSY P/R
Disconnect P/J201 from MOTOR ASSY P/R.
The voltage of J201-1 ↔ J201-2 is 24 VDC?
Go to Step [12]. Go to Step [13].
12 Continuity check of HARNESS ASSY MAIN
Disconnect the P/J403 from PWBA MCU.
Is the continuity normal between all terminals
of J403 ↔ J200?
Replace PWBA
MCU. (p.404)
Repair broken
or shorted part.
13 Continuity check of HARNESS ASSY MAIN
Disconnect P/J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J502-9 ↔ J201-1
J502-10 ↔ J201-2
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.
14 5 VDC power supply check to PWBA MCU
The voltage of P410-3 ↔ P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU. (p.404)
Go to Step [15].
15 Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3 ↔ J502-3
J410-4 ↔ J502-4
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.

May 22, 2008 | Epson Aculaser C1100 Printer

2 Answers

Worn Photoconductor Epson C1900 laser Printer


hi this solution has already been covered in full lengths. Epson c900 and c1900 are similar. have a look at my posting on this. photoconductor reseting by Labatt in this forum. read from the start.
http://www.fixya.com/support/t146110-epson_aculaser_c900_photoconductor

Jan 29, 2008 | Epson AcuLaser C900 Printer

Not finding what you are looking for?
Epson AcuLaser C900 Printer Logo

439 people viewed this question

Ask a Question

Usually answered in minutes!

Top Epson Office Equipment & Supplies Experts

Les Dickinson
Les Dickinson

Level 3 Expert

18381 Answers

mukhtar21 shaikh
mukhtar21 shaikh

Level 3 Expert

2017 Answers

Cindy Wells

Level 3 Expert

4948 Answers

Are you an Epson Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...