1 Answer

I have a brivis buffalo ducted heating system over 10 years old. No hot air is being supplied. control box has a red flashing light and is also beeping.

Posted by on

1 Answer

U can down load a manual from brivas it has the trouble shooting page in the PDF

Posted on Oct 07, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Zone control


reset the zone system and see if it still flashes

May 23, 2014 | Fujitsu Heating & Cooling

1 Answer

Carrier fb4bnb070


I know this thread is a little old but I thought the question has still been left unanswered. Tonnage is assumed. But, CFM and BTUs are exact.
If anybody wants to know the true size of their a/c or heating system you need to go where the engineers go.
http://www.ahrinet.org/Home.aspx

Consumers and contractors need to rethink their thinking when it comes to whole house heating and cooling... (Im from a hot humid area in the USA) Hot dry areas have other needs I won't.
ie... an air conditioner is no longer BTU's in a box. They have evolved into computers. computers that drive the blower motors, the expansion valves, the thermostat/controller can tell you the sub cooling, superheat, and the delta-t. Some tell you if the duct work is incorrect, static pressure against the blower. They are also not as forgiving if installed incorrectly.
Our industry is just catching on, but the consumer is untrustworthy when it comes to duct work and static pressure.
And in our high humidity market having high airflow with low static pressures removes far more humidity then a duct system installed over 10 years ago, Also, most homes lack proper return grille sizes, when the homeowner's desires are to put MERV 16 filters.
Here is a very useful link for duct and grille sizing.
http://efficientcomfort.net/Charts/Rules_and_Rules_of_Thumb_for_Duct_Systems.pdf


Carry on my friends,

P.S. a neat little read,

http://www.energyvanguard.com/blog-building-science-HERS-BPI/bid/55629/Why-Is-Air-Conditioner-Capacity-Measured-in-Tons

Apr 22, 2013 | Heating & Cooling

1 Answer

I have a Brivis buffalo 26 unit...the heating is on but it's blowing cold air the pilot doesn't seem to be light but I don't know how to relight it!


Try adjusting your thermostat, contact point possibly melt and welded by electric sparks. Replace thermostat control if contact won't get open.

Sep 02, 2011 | Heating & Cooling

1 Answer

When main gas valve opens to start burners the gas pauses then ignites with a high volume woof.The pilot flame looks a little small could this be the issue. This unit is Brivis Buffalo year 1988 model...


The problem is called "Delayed Ignition". This can be caused by burner & pilot obstructions (dust, lint and/or pet hair) and needs to be thoroughly cleaned. At 23 years old, I'm surprised the unit is still in service.

Hope this helped you to troubleshoot and solve the problem.

Apr 28, 2011 | Heating & Cooling

1 Answer

MY BRIVIS BUFFALO UNIT HAS AN ELECTRONIC GAS RE-IGNITOR THAT CLICKS AND DOES NOT STOP CAN I REMOVE IT.


Hi you will need to replace the thermocouple, which is in the burner chamber lower left side. You will probably find that the end has burnt through. The control system is trying to establish the pilot light and will not stop the clicking until a signal is returned through the pilot flame to confirm the flames existence. Col R. digitalcontrols.com.au

Mar 03, 2011 | Heating & Cooling

1 Answer

Hi We have just arrived back in Wellington from overseas. Our house has a gas central heating system - the unit is Brivis Buffalo 20. What we would like to know is how cost effective the Brivis Buffalo 20...


Hi, if you are planning to change this system out, please stay with a gas fired central system as compared to a heat pump, they are much more cost effective. Heat-pumps have so many problems as there are more parts on them to go wrong. The compressor and condenser fan motor run year around as with a heat-pump they use what is called a reversing valve that changes the flow of freon making the indoor coil the outdoor coil and the same with the outdoor coil becomes the indoor coil in the winter season. I can recommend excellent gas fired units compared to the Brivis unit you have that is much more cost effective, such as the Bryant, Carrier, Goodman. I would go with a Bryant and talk to a dealer. Stay away from a heat-pump no matter what they tell you as I have worked on them for many years and if you have gas available, stay with gas. You will heat your home much faster and save on electricity as this heat -pump units need heat strips for back up heat as they can't keep up the temperature with out them. I hope I have been of help to you on this, and you will be kind when rating me as I know you will. Please contact a Bryant dealer as you will not regret it.
Sincerely,
Shastalaker7
A/C, Heating, & Refrigeration Contractor.

Sep 05, 2010 | Heating & Cooling

1 Answer

Got a pyrox comfort control ducted gas heating system cant heat house above 19 dec have to keep hitting reset button every 10 mins, have cleaned the filter still doing the same, have heard the comfort...


on the reset switch there should be a temp. cut out take a temp. reading and see if it is realy getting as hot as the switch is rated for maybe the switch is bad

Aug 11, 2010 | Heating & Cooling

1 Answer

Heating isn't working, can't find the red button to relight the pilot


Many times the knob to turn the gas on on the valve is also the pilot knob. Turn it to pilot and hold it down while you light the pilot. Hold it for up to a minute and release. If the pilot stays on then turn it to on. If not you need a new thermocouple.

Apr 26, 2009 | Heating & Cooling

1 Answer

Brivis Ducted Heating system. No display on Programmable controller inside hoiuse. Electronic Control (Model 14100) located on Heater (outside house)displays "Searching". Have turned off...


Hi,
I have an identical issue with my Brivis.
Did you get a solution?
Mine can be running, then goes blank and says searching. it will eventually come back.
Just wondering if you had to replace the 14100?

Cheers
James

Jun 10, 2008 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

1,845 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2046 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Cris Sparks
Cris Sparks

Level 2 Expert

338 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...