Question about U-Line BI-95

1 Answer

Electrical wiring diagram for BI-95

I need an elecrical wiring diagram for BI-95

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

U-Line Emailed me the wiring diagram.

Posted on Oct 07, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why is there a bad taste and smell in water in all faucets


Could be old pipes you should get a new clean glass container, get a water sample and take it to the water department and have it tested. I would not drink it until you have it checked.

Jun 17, 2014 | U-Line BI-95

1 Answer

Need a new door and gasket. Murray


You can order parts by going to www.u-line.com and under customer service you willsee parts locator. There you will find a distributor for your area.

Sep 21, 2009 | U-Line BI-95

1 Answer

Will not get cold. the compressor isrunning all the time and will not make ICE. It has a brand new ice maker unit in it, thermostat, and watervalve from last year.


A BI 95 will run until the thermostat is satisfied. The it closes contacts between red and yellow to advance icemaker. Make sure thermostat is set at a warmer temperature. 10-15 degrees is what your looking for in the bucket. After you turn it down and it doesnt cycle then make sure it wires right. Red terminal 1 yellow terminal 2 blue/black terminal3 Or it could be to warm (heavy frost needs defrosting) If everything is running and not cooling then a sealed system is expected. Also make sure you have the right icemaker if not then that could cause everything. Sensor needs to be in the tube about 12 inches.

Aug 12, 2009 | U-Line BI-95

1 Answer

Smell in kitchen water


Is your supply line plastic or copper? If its plastic then that can absorb a smell. There is nothing in the icemaker that would make it smell. You may need to replace the supply line and the inlet line that feeds the icemaker. Is there a smell in the kitchen faucett?

Aug 12, 2009 | U-Line BI-95

1 Answer

I have an old U-line ice maker. I can not find


The mechanical parts of those models is the same as a BI 95 or BI98. If your looking for the faceplate that would be part number 150. This includes the timer motor,gears,water switch, and hold switch. You can order this thru a parts distributor. Appliance Parts Depot or All Brand Parts should be able to help. If you want to replace the complete icemaker assemly that part number is 402

Jul 04, 2009 | U-Line Icemaker

1 Answer

Give-me plis a wiring digram manual of the Ice Maker U-Line BI-95


Your going to call U-line and ask for it. 800-779-2547. Now what are you trying to do? I can give you the wires on the thermostat. Terminal 1 is red(icemaker) Terminal 2 is yellow(common) Terminal 3 is blue/black(compressor and cond fan motor) When yellow and blue or black are closed this will run the compressor and fan.Thermostat is satisfied then the red and yellow are closed and it advances the icemaker. Ejector blade at the 12 oclock calls for freeze cycle. at 2 calls for heater to come on(inside icamaker) at 10 oclock it trios the water switch and calls for water.Then back at 12 oclock calls for freeze cycle. Temps should be 10-15 degrees in the bucket. Warmer the setting the more ice it makes.

Jun 30, 2009 | U-Line BI-95

1 Answer

U line BI 95 icemaker is making but not ejecting made Ice


First thing to do is find the temp in the bucket. Should be between 10-15 degrees. If its colder then try turning the thermostat to a warmer setting. If its warmer than this then the unit is not getting cold enough. Look at the cendenser to make sure that its clean. If thats good you might have to check the thermostat. (if its 10-15 deg) Check the wiring. red goes on terminal1 yellow on 2 and blue /black on 3. The control might not be switching to harvest position. Wait until you hear the compressor and fan shut down then look at the icemaker. If not advancing then replace the thermostat.

Apr 30, 2009 | U-Line BI-95

1 Answer

U-Line BI-45A won't run


check the wiring diagram at the back panel. trace each component.

you could have disconnected one or two wires while replacing the fan, check the thermostat control. see if there is continuity. check the wirings also that went there.

tnx 4 using fixya,

drcool

Oct 19, 2008 | U-Line Icemaker

2 Answers

BI-95 ULINE


raritan eng/whirlpool ice maker assembly

Jun 20, 2008 | U-Line Icemaker

Not finding what you are looking for?
U-Line BI-95 Logo

Related Topics:

469 people viewed this question

Ask a Question

Usually answered in minutes!

Top U-Line Kitchen Appliances - Others Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Iron
Iron

Level 3 Expert

3018 Answers

Gil Shultz

Level 3 Expert

3320 Answers

Are you an U-Line Kitchen Appliances - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...