Question about Whynter FX-6SB Free Standing Hot & Cold Water Dispenser with Storage, Microcomputer-controlled LED D

1 Answer

Sunbeam Model YLR2-5-90HZ3 hot/cold water dispenser w fridge

Fridge works but the water does not get cold

Posted by on

  • 1 more comment 
  • mountpl Oct 06, 2008

    The cold tap is leaking about 2 cups a day. I am looking for the manual and a place wher I can buy parts to fix the problem.

  • Anonymous Jan 19, 2009

    cold water tap leaking

  • Anonymous Mar 30, 2014

    Water will not dispense from the cold water tap

×

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

HOW CAN I REPLACE THE PART MINE IS DRIPPING WATER CONSTANTLY.

Posted on Nov 15, 2008

2 Suggested Answers

  • 2 Answers

SOURCE: model YLR2-5-90HZ3 cold/hot/water dispnser with fridge won't heat

I have the YLR2-5-96H2 and hot water stopped heating up. I unscrewed the casing and unplugged the connections to the circular heating element and 2 circular probes. Brushed off the white dust build up on the probes and it started to heat water again. I ruled out faulty heating element, because it got really hot just seconds after turning on the hot water switch.

Posted on May 23, 2011

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Ro filters going bad in 60 days


IF THE RO OR ANY T33 FILTER HAS BEEN INSTALLED HORIZONTALLY, TRY TO INSTALL IT VERTICALLY WHERE THE OUTPUT IS ON TOP. GOD BLESS.

Jan 29, 2012 | General Electric Profile Smartwater Ultra...

1 Answer

I have a GE PROFILE R/O System with a chrome dispenser; I need a brushed nickel dispense; where can I get one???


An RO drinking water air gap faucet would be the ideal faucet to purchase for your RO system. Here are a few options you can choose from that may come in brushed nickel: http://www.freshwatersystems.com/c-821-ro-drinking-water-air-gap-faucets.aspx

Jul 31, 2010 | General Electric Profile Smartwater Ultra...

1 Answer

Lost manual fo model pnsf39z


Hi,

You can download the complete instruction manual in PDF format by clicking this link.

For additional information, features and specifications, click here
  • You'll require Adobe PDF Reader installed on your computer to view the manual. If it is not already installed on your computer, download it free from: http://get.adobe.com/reader/
Hope this solves your problem. Thanks for using FixYa.

Apr 08, 2010 | General Electric Profile Smartwater Ultra...

1 Answer

Indicator lites on the GE RO facuet do not lite. Batteries have been changed several time and the filters are not that old.


If you have concern about the quality of water being produced by your RO system, I would recommend using a handheld or in-line TDS meter. Instead of a red or green LED, these meters will give you a reading of TDS (total dissolved solids) in parts per million (PPM). With either of these meters you are taking a reading from the feed water to the system as well as from the product water, you then can calculate the percentage of solids being rejected by the RO system (using the simple equation listed below). This way you will know exactly how well the RO system is working and when the membrane needs to be replaced. I have included links below to our selection of handheld and in-line TDS meters as well as an instructional video that explains how to use a handheld TDS meter.

Here is a helpful link that includes the formula for calculating percent rejection.
http://www.freshwatersystems.com/t-measuretds.aspx

Handheld TDS Meters - http://www.freshwatersystems.com/c-253-handheld-meters.aspx
In-line - http://www.freshwatersystems.com/c-255-in-line-monitors.aspx



Geoff D., CWS-I - WQA Certified Water Specialist
Fresh Water Systems, Inc - http://www.freshwatersystems.com 1.877.335.3339

Mar 20, 2010 | General Electric Profile Smartwater Ultra...

1 Answer

Kinetico water filter leak


Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} What you are describing sounds like a quick connect fitting. I have included a link below to a video that explains how this type of fitting works. If you are using plastic tubing with these fittings you may be able to remove the tubing from the fitting and cut back about ½” from the end of the tubing and reinsert it into the fitting. Do not cut the tubing with scissors, use a tubing cutter or razor blade knife (see video). If that doesn’t solve the leak and you find that you need to replace any fittings we have a complete selection located here: http://www.freshwatersystems.com/c-276-fittings-valves-tubing.aspx


Geoff D., CWS-I - WQA Certified Water Specialist

Fresh Water Systems, Inc - http://www.freshwatersystems.com 1.877.335.3339


Mar 16, 2010 | General Electric Profile Smartwater Ultra...

1 Answer

GE smartwater R.O. system leaking out weep hole


Same exact problem started for us last night. (Same model, installed by me about four+ years ago) Water was really coming out of the weep hole, and didn't stop until I shut it off at the valve. This happened once before, and all I had to do was clean the drain line adapter, because it gets full of gunk from the disposal over time. But this time that did not do the trick. (Plus there was not all that much gunk this time....) So I was baffled for awhile but came up with this solution.

I hooked up a small length of clear tubing to my cheap-o tire inflater/air compressor. Put the clear tube against the weep hole. Turned on the compressor, and VOILA!, a bunch of gunk that was clogging the drain tube came out. I think when this tube, or the drain line adapter gets clogged, it causes water to go out the weep hole instead of down the drain. (If you don't have a small compressor, then theoretically there is enough air pressure from something like a bicycle pump, and this solution *might* work with one of those. But if you try this, of course only use the DOWNWARD (air-going-outward) pump action...pulling up (inward) would force the clog deeper up the drain tube)

May 28, 2009 | General Electric Profile Smartwater Ultra...

1 Answer

I have a ge reverse osmosis filtration system and recently lost pressure and tank capacity. I have only had the system about a month and my water has been tested fine. I did leave town for 10 days, could...


Make sure that all valves are in the open position.
Try to recharge the water storage tank. Here are the steps to follow.
* In General: When any type shut-off valve handle is positioned so that it is parallel or in line with the tubing that enters the valve, valve is OPEN. When handle is turned perpendicular to tubing that enters valve, valve is CLOSED.

Necessary Supplies:
1) Tire Gauge marked in 5psi increments (ie 5, 10, 15, 20psi, etc.)
2) Bicycle tire pump for standard type bike tire valve
To recharge RO system tank:

1) Close cold water feed valve (valve located at some point along the cold water line from street plumbing).*
2) Leaving RO tank valve on, turn tank on side & locate valve stem on bottom side.
3) Remove stem cap.
4) Drain all water out of tank through open RO faucet into sink. (Continue to leave RO faucet open throughout procedure)
5) If current tank pressure is insufficient to empty tank, apply tire pump to valve stem and pump 10 – 15 times. Exit flow will increase and then gradually decrease as pressure equalizes. Do not overcharge internal bladder of tank during this
procedure.
6) Repeat step #4 until tank is completely empty. (Tank is empty when additional pumping produces no more water)
7) At this point, adjust EMPTY tank to exactly 7psi. (Gauge reading midway between 5 & 10psi is sufficient)
8) Turn off RO faucet.
9) Replace cap on valve stem and reposition tank in upright position.
10) Open cold water feed valve.*
11) System water is useable immediately, however, tank will take 3-4 hrs to completely refill.

www.FreshWaterSystems.com: The Water Super Store: 1-877-335-3339

Apr 27, 2009 | General Electric Profile Smartwater Ultra...

Not finding what you are looking for?
Whynter FX-6SB Free Standing Hot & Cold Water Dispenser with Storage, Microcomputer-controlled LED D Logo

5,579 people viewed this question

Ask a Question

Usually answered in minutes!

Top Whynter Water Filters & Coolers Experts

Brad Brown

Level 3 Expert

13732 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Are you a Whynter Water Filter and Cooler Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...