Jason Few Posted on Dec 22, 2011

Temp controll just flashes 00 and unit not running

Replaced temp control board but still the same screens stay blank untill you push one of the controls and then it just flashes 00 00 00 and unit does nothing only thing working is the light.

4 Related Answers

Anonymous

  • 89 Answers
  • Posted on Dec 17, 2007

SOURCE: GE Arctica Profile getting too cold, temp set to 37 actual temp is 25-35

Wow, so you dropped some money into it, eh? I would take a look at the damper door asslb(DIFFUSER). located at the very top left of your refrigerator section in back. It has a motorized door that opens and close's and it may be stuck open. More than likely it is broken and needs to be replaced. GOODLUCK!!!!

FYI: All your cold air in your refrigerator comes from your freezer!

Ad

Anonymous

  • 90 Answers
  • Posted on Jan 05, 2008

SOURCE: the letters hrs are blinking on the temp control panel

Unplug for 3 minutes. Plug back in see what happens.

Anonymous

  • 1665 Answers
  • Posted on Jul 04, 2008

SOURCE: Ice and Water not dispensing. Light button not working

http://www.repairclinic.com/0100_1.asp
There's an ice- or water-dispensing problem The ice and water-dispensing system of your refrigerator is quite complex. Many components work together to provide the ice and water. Aside from a simple problem of a leaky water tube or a jammed ice chute, most other components are not user serviceable. We suggest that you contact a qualified appliance repair technician for such repairs.

Anonymous

  • 66 Answers
  • Posted on May 19, 2010

SOURCE: Freezer temp is fine: around 12'F. Crispers stay

check fan , in freezer, it distributes air to fridge, also make sure fridge is level, if its not doors can open slightly

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

After turning off the unit the display is off but the unit is still running.

If it has humidity control and the cool is still on but set temp is higher than the room temp, the humidity control will override set temp. If it has no %rh control then it probably has a circuit board fault; micro relay is stuck closed and board needs to be replaced. Its probably the circuit board. On it, there is a little black box(s). About 1" X 1/2" in size. With long run times the small contacts inside will fuse/melt together.
0helpful
1answer

How to program a whirlpool W10503278 control board

Programming Procedure:
The replacement control board is not programmed The Refrigerator will not operate without a code selected. It is important to program the control board with the correct code. Product must be powered up to program. If no code has been programmed the display will display 00 or flashing 00.
Note: The program code for this refrigerator is located on the serial plate on this unit after the word Code.
1. Open the fresh food door and hold the fresh food door light switch closed while pushing the freezer temperature down key pad 3 times consecutively.
2. Release the Fresh Food door light switch.
3. The control will display PE to confirm entry into the programming mode.
4. Entry is confirmed by pressing the Freezer Down key once more.
5. The control will display no Program Code.
6. To set the desired Program Code number, press the Freezer and Refrigerator UP keys. The corresponding digit will be advanced with each key press.
7. Once the desired Program Code is displayed, press the Freezer DOWN Key until the Program Code begins flashing indicating it has been saved.
Note: If you attempt to enter an invalid Program Code the control will not save the code, but will flash Program Code 00, (The unit will NOT run with a Program Code of 00).
8. Once the Program Code has been saved the Programming Mode is exited by closing the Refrigerator door(s).
Note: If you to enter a wrong Program Code the control can be reprogrammed by restarting the procedure from the beginning.
0helpful
1answer

Just purchased and is not cooling at all

please see this steps and fix it. God bless you

1. Unit not running

Possible Causes Response a. Power cord unplugged
b. No power at all
c. If display lighting, temp setting high
d. If temp setting ok, sensors or control board bad
e. Compressor unit malfunctioning a. Check for power cord plug
b. Check receptacle voltage & fuses
c. Lower temperature setting
d. Call service for replacing sensors or control board
e. Call service for component check
2helpful
1answer

I have just replaced my circuit board (balboa 53247) for my eclipse hot tub and as soon as I plugged the unit in, I got an OH reading from the top-side control. Then I noticed that if I pulled the temp....

Unfortunately, I would have started with the sensors and then escalated from there. A hot tub is one of those items that I generally recommend hiring a technician to sort out, it's just flat not worth the headache of troubleshooting without the know-how.

As for your particular problem, the OH code on a Balboa control pack is "O.ver H.eating" it means that the heat sensor detected high temp and shut down to prevent damage to the system (as well as cooking you like a pink lobster) The sensor could be bad or the control board could be malfunctioning. A new sensor is $75-85 if memory serves me and is relatively easy to replace. one sensor is in the heating tube and the other is screwed into the tub shell to monitor tub temp. I would suggest new sensors, both of them because when one goes out the other usually isn't far behind. Make sure you shut the power to the tub off at the breaker box before doing any kind of tub repair. If you have shutoff valves on your tub you can replace the internal one without draining the tub. the one in the shell you need to drain to replace (at least to the sensor hole level) I hope this helps you to get your tub working properly again, if you still experience issues after this, I suggest biting the bullet and calling in a tech. Thanks for your question =)
0helpful
1answer

2004 pacifica won't stay running. temp gauges are erratic. No code on PCM

The PCM on a 2004 Ford Mustang is a combined control unit, consisting of the engine control unit (also known as an ECU) and the transmission control unit.------------------------------------------------------------------------------------------
Launch X431 Master
2helpful
1answer

I own a 1994 Dodge intrepid and am having an issue with the Air Conditioner. It stays running all the time. The controls have no affect none of them, I can't change the area it blows or nothing. None...

your electronic climate controller is bad, and needs to be replaced, it is now running in the default position. Best pace to find one is in a local junkyard or on ebay.
0helpful
1answer

1994 Dodge intrepid won't kick in when turned on.I have already replaced climate control unit.

I am assuming your talking about your ac. if so you can run a self diagnostic check, if you have manual temp control the led on the rear defogger can blink codes. turn car on, turn blower knob on(anyspeed), temp full cool, zone to defrost. press defogger button for 5 secs until it blinks. if it goes out 1st test is ok, rotate zone control and each section will be tested, the light will blink for each zone and then go out if it is ok, if it stays on this may be where your problem is.
1helpful
1answer

Frigidaire phsc239dsb0- temp controls

e-f relates the evaporator fan. lasttime i had that happen it was problem with the mother board located under the refrig, replaced it and all was well
14helpful
3answers

How do i reprogram my HV board?

HERE TIS RIGHT OFF THE INSTRUCTION SHEET.  THE TECH JUST LEFT. POWER UP REF. PROGRAM CODE IS LOCATED ON SERIAL PLATE ON THIS UNIT AFTER THE WORD CODE.-1. PRESS & HOLD THE DOOR ALARM KEYPAD.-2. PRESS & HOLD FREEZER TEMP DOWN KEYPAD.-3. RELEASE DOOR ALARM KEYPAD AND WAIT 3 SECS.-4.CONTROL WILL DISPLAY PE TO INDICATE PROGRAMMING MODE-5. ENTRY IS CONFIRMED BY PRESSING TEMP DOWN - KEYPAD ONCE MORE.-CONTROL WILL DISPLAY CURRENT PROGRAM CODE. THIS VALUE SHOULD BE VALIDATED THE THE PROGRAM CODE PRINTED ON UNIT SERIAL PLATE.-NOTE: IF PROGRAM CODE IS CORRECT, THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOOR.-7.PRESS REFRIG TEMP UP KEYPAD + OR REFRIG DOWN KEYPAD -TO CHANGE THE DIGIT VALUE WITH EACH KEY PRESS.-8.THE DECIMAL POINT INDICATES THE SELECTED DIGIT. PRESS THE FREEZER TEMP UP KEYPAD + TO SELECT NEXT DIGIT.-9.ONCE DEIRED PROGRAM CODE IS DISPLAYED, PRESS AND HOLD THE FREZZER TEMP DOWN KEYPAD - UNTIL UNIT PROGRAM CODE BEGINS FLASHING INDICATING IT HAS BEEN SAVED. *note* IF YOU ATTEMPT TO ENTER AN INVALID PROGRAM CODE, THE CONTROL WILL NOT SAVE THE NEW CODE, BUT WILL BEEP! (THE UNIT WILL NOT RUN RUN WITH A UNIT PROGRAM CODE OF 0000). ONCE THE PROGRAM CODE HAS BEEN SAVED THE PROGRAMMING MODE IS EXITED BY CLOSING THE FRIG DOORS. 
Not finding what you are looking for?

287 views

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Johnny 1000

Level 2 Expert

94 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...