Question about Emerson Heating & Cooling

2 Answers

Wiring Diagram for a Emerson Motor in a Tempstar Central A/C

I am attempting to replace the fan motor (Emerson Model #K48HXFPH3956), but lost my homemade "map" to re-attach the wires in the central air unit (Tempstar Model #NAC030AKA5). Can you help me? The wire colors are black, brown, red.

Thanking you in advance...Steve Smith

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

EMERSON 1/4 HP MOTOR 5 WIRES BLACK BLUE BROWN WHITE RED LOST MY DIAGRAM 115V1075 RPM 3 SPD HOW DO I WIRE IT TO THE COMPRESSOR

Posted on Jun 08, 2010

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 121 Answers

Hey Steve,

Brown is for the compasitor, black is common, red is the speed. black and red go to the contactor and brown to the run cap. 5mfd

Posted on Sep 27, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Tempstar indoor outdoor central air unit is so noisy you can't hold a conversation. any lubricant's i could use and where.


I'm assuming you have an air handler that is inside. Turn the power off and make sure there is nothing that the fan is hitting. If not the bearings are probably bad. These motors are sealed and cannot be lubricated. You will need to replace the fan motor.

Jul 16, 2016 | Heating & Cooling

1 Answer

Could sure use a wiring diagram for a Dayton 5k961c motor.


Electric Motors: dayton motor, Electric motor repair Kansas ...

en.allexperts.com > Industry > Machine Tools > Electric Motors
Aug 24, 2010 - Electric motor repair Kansas City MEAR Service 816-650-4030: Tyler, it is ... i have a dayton motor with no wiring diagram. i need a wiring diagram for a dayton motor with a model # 5k961c and a reference # r67745ck733 ... 1992 Dodge Dynasty Blower Motor Wiring Diagram · 1998 Ford Escort Blower ...

wiring diagram (ideally color) for Dayton belt drive motor Model ...

www.electro-tech-online.com > ... > General Electronics Chat

Apr 29, 2012 - 9 posts - ‎3 authors
There is a sticker on motor indicating wiring, but seems only an. ... This is a motor for vented - big blade ceiling fan -- a belt driven Dayton Motor ...

DAYTON 1/4 HP Condenser Fan Motor,Permanent Split ...

https://www.grainger.com/.../DAYTON-1-4-HP-Condens...

W. W. Grainger
Rating: 3.8 - ‎6 reviews
Shop DAYTON 1/4 HP Condenser Fan Motor,Permanent Split Capacitor,1075 Nameplate RPM,208-230 ... Typical HVAC Condenser Fan Motor Wiring Diagram ...

DAYTON 1/3 HP Direct Drive Blower Motor, Permanent Split ...

https://www.grainger.com/.../DAYTON-1-3-HP-Direct-D...

W. W. Grainger

Jan 23, 2016 | Dayton Dryers

1 Answer

Looking for wiring diagram for a Emerson motor k55hxgwl-4241


The wiring diagram comes with the new motor if you lost it send info about unit and colors of wires coming from motor .

Nov 15, 2014 | Heating & Cooling

2 Answers

I need a wiring diagram for an Emerson condenser fan motor k55hxkwa-9803. More specifically I am looking for how to reverse the direction of the motor.


For the Emerson Rescue EchoTech Motor (M055PWCRY), sometimes the handy reversing method (simply flipping the connector around) fails to work right and the motor keeps going the wrong way. Attached are photos showing how to open up the motor and then there are 2 steps to try. If step 1 fails to get the motor going the right way, move on to step 2. After performing step 2, simply removing the jumper will change the motor direction. The reversing plug-in connector will no longer have any effect after following the instructions in the photos.

need-wiring-diagram-emerson-condenser-a1wqc0u41majirzwx55hyegg-4-0.jpg

need-wiring-diagram-emerson-condenser-a1wqc0u41majirzwx55hyegg-4-1.jpg

need-wiring-diagram-emerson-condenser-a1wqc0u41majirzwx55hyegg-4-3.jpg

need-wiring-diagram-emerson-condenser-a1wqc0u41majirzwx55hyegg-4-6.jpg

Jun 30, 2013 | Heating & Cooling

1 Answer

My old motor on my central air unit has 4 wires and my new motor has 5 wires. wich brown wire do I use and what do I do with the extra one


There should be a wiring diagram on the side of the motor. Usually when you have two brown wires they connect to the terminals on the capacitor.

May 05, 2012 | Emerson Condenser Fan Motor 1/6 Hp 230v...

1 Answer

I was wondering if there are different fan speeds for my tempstar joist hung furnace and where do i find these


Generally ther are at least three speeds and the wiring should be on the motor if they are varible speed. There should be a wiring diagram on a small plate or sticker on the side of the motor.Hope this helps you. Thanks

Dec 27, 2010 | Heating & Cooling

1 Answer

I have emerson quiet kool but the fan with not turn it keep on making a miiiiiiiiii sound


Hi, what has happened here is you have lost the blower motor to the unit. Anytime a motor will not turn and makes noise as it is trying to start, the windings are about gone, and /or the bearings are froze up. I know this is a Emerson, but I don't know the model of this unit, or if it is a window/wall unit or larger. If it is a wall type unit, it will have a dual shaft motor in it for the blower and condenser fan. It would not be worth the cost to have this motor replaced unless it is a Emerson central heating and air system. It is possible that this unit has a run capacitor on it that may have failed, but when this happens the motor will just stop and not make any noise at all. The motor needs to be changed out if its a central unit, and if you want to get an estimate to change it out if its a window or wall unit you can, but it may cost you more then the unit is worth, just to be honest from my years in this business. Please keep me posted on this and what you decide to do. Please don't forget to rate this post as I know you will be kind. I wish I had better news for you, but this happens and there is not much you can do your self. I wish you the best.
Sincerely,
Shastalaker7
A/C, & Heating Contractor

Sep 25, 2010 | Emerson Heating & Cooling

1 Answer

Need a wiring diagram for emerson k55hweym 3739


green is ground. white is common. blue and orange are hi speed/low speed. brown goes to the capacitor.
Both motors should have the wire diagram on the side of the motor.

Jul 03, 2009 | Emerson Quiet Kool 10MW42K Air Conditioner

1 Answer

I have a tempstar 2000 heat pump approx 5 years old. The condenser fan blades will not rotate/operate; however, I can hear the motor hummming. When the unit is off, I can rotate the fan freely. When the...


I think this is a double problem post,so I will answer the top first.
The fan capacitor may be bad or the motor it's self is seizing up and will need replaced.

Second portion of post:
  1. Brown and brown/white go to the new capacitor(If you didn't get a new one with the motor,You will need to)Should be 7.5 mfd
  2. Black To the contactor where the black was originally connected
  3. yellow to the contactor where the red was originally connected

May 06, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

3,140 people viewed this question

Ask a Question

Usually answered in minutes!

Top Emerson Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Tim Whalen

Level 3 Expert

3072 Answers

jack morton

Level 2 Expert

338 Answers

Are you an Emerson Heating and Cooling Expert? Answer questions, earn points and help others