Aprilaire 700 Humidifier Logo
Posted on Sep 25, 2011
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

My humidifier is a Carrier and uses the square evaporator cartrages. There is a drain pipe coming out of the bottom that goes to a floor drain. I've noticed that there is a slow drip here all of the time when the humidifier is on, but furnace off. Is this normal?

1 Answer

Robert

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

  • Aprilaire Master 1,036 Answers
  • Posted on Sep 25, 2011
Robert
Aprilaire Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

Joined: Dec 19, 2010
Answers
1036
Questions
8
Helped
345771
Points
3136

Hello, no the humidifier should be running only when the blower motor is running. Sounds like the solenoid valve is faulty if water keeps drainig from humidifier.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Leaking at base due to too high of pressure or defective evaporative filter?

Humidifer FAQ's - General Filters, Inc.

www.generalfilters.com/support/faqs/humidification.html
I already have a GeneralAire® 1042 Humidifier installed, but have a 4,000 square foot home. Should I ... Can't I simply clean my Vapor Pad instead of replacing it? Where do I find ... I am seeing a very slight water leak coming from the bottom of my steamhumidifier. What do I do ... Legacy 1137 = 21 GPD / Up to 3,000 Sq. Ft.

GeneralAire® Legacy 1042 and 1137 Humidifiers - YouTube

? 3:22
https://www.youtube.com/watch?v=IM6IXVcjEdU
Jun 27, 2013 - Uploaded by GeneralAire Inc
GeneralAire® Legacy 1042 and 1137 Humidifiers - How to change the vapor pad .... Evaporator Pad (aka filter) change on aGeneral Aire 1042 ...

[PDF]General Aire Humidifier Owners Manual - On Time Mall



2helpful
1answer

Water leaking / running from top of humidifier

humidifiers have a drain and if there is water going in it will be coming out the drain. check drain to see if it is clear, check hoses going into top of humidifier for cracks, check filter in humidifier.
0helpful
1answer

My carrier humidifier has a hose which drains into the laundry sink and a lot of water is coming out. Should this happen in winter? I thought water should only come out in the summer?

The humidifier should run in winter, however if the windows are fogged up it means the humidistat is set too high. Try lowerimg the setting on tue humidistat.
3helpful
1answer

The clear plastic drainage tube that runs from our Aprilaire furnace humidifier into the basement floor appears to be clogged with brown gunk. How can we clear this line.

One way of removing the gunk is to disconnect the tubing from the humidifier and use a flexible and thin rod that will fit in the tubing and try to dislodge it, or you can try using a shop vac and see if the suction pressure will remove it. If the tubing is really clogged then sometimes it's better to just replace the vinyl tubing with pvc pipe and drain it to the floor drain, I always prever pvc pipe over vinyl tubing when it comes to drain lines for humidifiers.
0helpful
1answer

Should water be draining out of the bottom of the unit?

Yes there should be a hose or pipe connected to the bottum of the humidifier so it can drain properly.
0helpful
1answer

Water leaks out from the bottom of the case ... just about where the outflow pipe is located. Additionally, large amounts of water are going out the out flow pipe. I am getting more than 2 quarts of...

YOUR HUMI IS IN NEED OF MAINTAINACE. THE CALCIUM DEPOSITS ARE CLOGGING THE THE SPONGE ROLLER THAT WOULD NORMALLY ABSORB THAT WATER, YOU ALSO HAVE THE HUMDITY SETTING RATHER HIGH THATS WHY THERES SO MUCH WATER. THE TUBE THAT IS LEAKING IS MADE TO DRAIN OFF EXCESS WATER FROM THE ROLLER AND THE REASON IT LEAKS IS BECAUSE IT ALSO NEEDS SERVICE JUST PULL IT OFF AND CUT THE SEWELLED PART OFF WITH RAZOR OR CUTTING KNIFE IF IT IS PLASTIC TUBING AND REPLACE IT. IT SHOULD BE DRAINING INTO THE DRAIN ON THE FLOOR WHERE THE FURNACE CONDENSATE TUBE IS.
0helpful
1answer

Water leaking from bottom of 550 aprilair humidifer

Hi they should be a hose going to a drain in the floor there are insrtuctions on the wed just google the make and model and you can down load them
0helpful
1answer

The unit leaks water on the floor

you need to replace the pad every season. if you are using a generic pad maybe more often. it also must be level and the drain coming off bottom clear. i suggest getting pads from aprilaire.com . not the generic from hardware store. also if its got a black feed tube going from the solinoid valve to the top of the humidifier pad you may want to replace that aswell, they have been known to crack the new ones are grey.
1helpful
2answers

Aprilaire 700 leaks water from bottom of case

Install new water panels yearly. On the new panel make sure that the painted dot on the edge of the panel is on the top when you install it.
Always clean the distribution tray and the frame. Make sure the notch on the edge of the distribution tray faces away from the furnace. Make sure the humidifier was installed level. Keep the drain tube opening clear. Insure there is no blockages in the drain tube.
Good luck
HVAC Teacher
0helpful
2answers

Routing waterline to pad

1/4" flexible copper pipe. Tap into your cold water line using the included saddle valve (pierces the pipe), attach the 1/4" flexible copper pipe to the saddle valve on the cold water pipe and the solenoid valve on humidifier unit using the included compression fittings. Tada!
Not finding what you are looking for?

337 views

Ask a Question

Usually answered in minutes!

Top Aprilaire Humidifiers Experts

Paul Carew

Level 3 Expert

3808 Answers

Cindy Wells

Level 3 Expert

6688 Answers

john h

Level 3 Expert

29494 Answers

Are you an Aprilaire Humidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...