Question about Heating & Cooling

1 Answer

Starting a Regency fireplace: gas is on, I turn the dial to pilot. I am suppose to push the dial in, spark the themocouple and hold it for 30 seconds. My problem is that the dial doesnt push in. The only place the dial pushes in is when it is in the off position...why not in the pilot position?

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 1,420 Answers

Can you spark it and does it light in the "off "position? Try it and see if when the pilot stays on, you turn it to pilot and the burner ignites.

Posted on Sep 19, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Lighting the pilot, starting the fireplace


Turn on the gas, hold the pilot flame button down and light the pilot flame, continue to hold the button for at least three min's, release the button pilot should stay lighted.

Jan 06, 2017 | Majestic Heating & Cooling

2 Answers

Pilot light of gas fireplace went out. Normally the pilot light is lit, and you turn on the fireplace with a light switch on the wall. Is it safe to relight the pilot with a match ?


if the stove or fireplace doesn't have electronic ignition then yes its looking for a pilot lite I used to have a old water heater that did this , turns out the problem was defective gas regulator making the pressures go up/down also was leaking outside that's what made it noticable

Dec 07, 2016 | Heating & Cooling

1 Answer

Is there a trick to starting the Pyrox 400? Turned the fan on and press on low then repeatedly press the ignition pilot light, start to smell of gas after a minute. Won't start Help please


Is the ignition sparking? When you press and hold down the buttons, the ignition should be sparking at the centre electrode. At the same time when you hold the buttons down, the gas valve is manually held open to release the gas. The spark is then supposed to ignite the gas. Hold the knobs down for about 3 to 5 seconds after ignition and the gas valve will stay on. If it lights but the flame wont stay on, it could be anything from a partially blocked aeration port to a worn knob. When you push down on the knob, it is supposed to press down on an electromagnetic lock which keeps the gas valve open when the flame is burning. When the knob or shaft isn't pushing down enough, it doesn't keep the gas valve locked and the flame will go out as soon as you let the knob go.

Apr 19, 2015 | Heating & Cooling

1 Answer

I also have a gas fireplace by DRU (Richeleiu). I accidentally turned the pilot flame off, but don't know how to get it ignited again. I tried the spark igniter and there is a spark, but nothing lights. I...


You need to push the gas supply knob inwards and HOLD it while lighting the ignitor.
Once lit keep holding for 15 seconds and release.
The gas thermo switch needs to warm up first before it will allow a constant flow of gas. Also called the gas fail save device.

Oct 23, 2013 | Heating & Cooling

2 Answers

We can get the pilot light on but the logs do not have a flame


If that is a millivolt type heater, the pilot generator is weak. It will hold the pilot but not operate the solenoid. Get a new pilot generator. If it works ok for a minute or 2 but dies then the pilot safety feature is dusty and nees to be blowed out.

May 09, 2011 | Heating & Cooling

1 Answer

We have an older (22 years?) 'Insta-Flame (model HE30 TN) natural gas fireplace insert. The pilot light is out, as we painted to inside of the firebox. The instructions show to 1) turn the dial to 'off'',...


On some gas valves the pilot setting is on the same dial as pilot on and on .on others the pilot light has aseperate button on right side of control dial. If yours has this there will be a cut out on cotrol dial that must be aligned with button to allow it to be depressed to light pilot. If yours has this align control dial cutout with pilot button,depress button and light pilot,hold for about one min. and slowly release,if pilot light stays lit,turn down thermostat and rotate control dial normally to right . There should be arrows or marks on dial and gas valve to line up. If pilot light stays lit turn dial to next position and check to see that pilot is still lit. This should be on position, turn up thermostat and burner should light. If your dial has pilot light setting on it then rotate dial to each position,try to depress dial and when you have right one dial will depress allowing you to light pilot. Follow same procedure as above and you should be in business. Hope this helps.Thank you

Nov 11, 2010 | Heating & Cooling

1 Answer

How to start a gas fire-place


Hi remove bottom cover you will see black knob with off pilot and on , turn knob to pilot push in and hold in press igntion button untill pilot lights hold knob in for 30 secs then release if pilot stays on turn to on postion if not try again ,

Mar 02, 2010 | Heating & Cooling

1 Answer

I recently bought a house w/ a Marco gas fireplace. There is no owners manual and the company has gone out of business. I have never used a gas fireplace, so I have no experience w/ this. It has a direct...


Hi the key turns the gas on there is a arrow saying on /off turn to on .

remove front panel should lift up then down look for large metal plate should have lighting instrutions on them?
if not you will see a gas valve 1 maybe 2 black knobs look for the one with off pilot on , look for small knob red or black this the spark igniton , okay turn first knob to pilot and press in and hold in depress spark knob keep doing this untill pilotlights there might be air in the line so this might take time , when the pilot lights HOLD BUTTON IN STILL for 30 secs then release turn knob to on pilot should stay on if not do again , if stays on turn up thermosat if fitted or turn power on at switch you will have to find that will be near fireplace the other black knob turn sthe flame up and down hope this helps

Feb 09, 2010 | Leisure HOMEPRIDE Electric Fireplace...

1 Answer

DRU fireplace, Model Richelieu Can't figure out how to start, which buttons and knops to turn, gas on, can see the starter sparking, pilot won't egnite. In a house I just purchased


Turn the gas knob to the PILOT position
Press down and hold whilst lighting the pilot
When the flame holds on its own turn the knob to the ON position. Then turn on the wall thermostat or whatever you have to control the fireplace.

Dec 17, 2009 | Washing Machines

1 Answer

Marco fireplace Model 794 cant light the pilot


the valve handle is on when the handle is in line with valve body, off when crossed...are you pushing in on the pilot gas valve under unit? if not.. open bottom panel.. turn knob to pilot..push and hold down while sparking..if pilot lights continue to hold for about 60 secounds.. then release knob and turn to on! Also FYI... these units have a vent recall on them! please go to google and type in your heater, then model #

Mar 25, 2009 | Leisure HOMEPRIDE Electric Fireplace...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

242 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2185 Answers

Dan Webster
Dan Webster

Level 3 Expert

8205 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides