My apc ups was working fine .Battery would give backup for just about 5 mins .When opening the ups to put a new battery , the cover of the ups touched the circuit and there was a spark and a puff of smoke .After that the ups has completely stopped working and does not even power on . What can be the problem ?

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 8 Answers

Just check the fuse and mosfets(the one with 3 pin ic's) and replace if necessary
recommended to handle if u r a technician with soldering and component testing knowledge.
remove the battery and re connect after 2 mins

Posted on Sep 13, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

APC 800va inverter is not charging


Yadava,

If you need pricing on a new or replacement unit I can help. You may also want to look into APC's Trade-Ups program where they give you a discount on new equipment as long as you provide a serial number for your existing: http://buy.apc.com/commerce/storefronts/tradeups/

If you need UPS, Surge, or Power Related help contact:
Inside Service Sales
Daniel Salazar 800.260.2259 daniel@psihq.com
Power & Systems Innovations, Inc.
customerservice@psihq.com

Power & Systems Innovations, Inc. is an Elite Certified Service
Sales Partner for APC/MGE brands manufactured by Schneider Electric

Visit us at www.psihq.com

Apr 18, 2014 | APC Smart-UPS RT 8000VA (0731304239635)...

1 Answer

APC RS 1500 82v output


Many UPS Systems have a squared wave when working on batteries. Cheap multimeters do not give the correct measure on squared waves. Connect a 100 watts resistive lamp to the output of the UPS, if the light is almost the same when UPS is working on batteries, everythinf is fine.

Dec 23, 2013 | APC BX 1500 Back-UPS XS 1500 (APNBX1500)...

1 Answer

Apc xs800 new batteries


I Bought two RBC32's and had to hook them up to the connector and did it wrong on the first try. Make sure you connect the yellow to the Red terminal on one battery and the Black on the other, then connet the remaining red to red on one and black to black to the other. Once I did that and plugged it back in everything worked fine.

Apr 06, 2012 | APC BX800 Back-UPS XS 800 (APNBX800) UPS...

2 Answers

Where can I get schematic for this unit?


Apperently APC has a policy against releasing schematics
Read

Positive Feedback ALWAYS Appreciated :)

Mar 06, 2011 | APC Smart-UPS DP 6000 UPS System

1 Answer

Mge pulsar ex10 stop after 5 min with 60W charge,after I changed the pack of 3 bateries with one new.if I switch off and on works again 5 min. all 3 bateries are good,Vcharge=13,6v Vin use=12,3v thanks


Some economics UPS have a functin called "Green Function". A timer disconnect the load after 5 min to prevent damages on internal circuit.
You can confirm this:

- battery remain to good level charge
- UPS restart for other 5 min if you press On button

See manual if you can disable this features.

Sep 28, 2009 | APC UPS Battery Backup Systems

1 Answer

House power fluctuates, UPS and computer die.


Sounds like the internal battery of the UPS needs replacement. Contact APC and ask for a qoute for a replacement battery/service. It'll probably work out a cheaper to buy new.

Make sure you dispose of the old unit properly if you do replace

Jul 07, 2009 | APC Back-UPS CS 500VA UPS System

2 Answers

APC external Backup battery is not working plz


It may just need a new battery. The UPS will do a self test on the battery when you turn it on. It may have tried to read the battery and the result came back as "failed". The batteries last about 3-5 years, even less if you live in an area with bad power. The batteries are very easy to change. You can buy replacements at www.batteryinternational.com/apc-backups-es-be350es-ups-battery-ups-batteries-f1.html

Jun 08, 2009 | APC Back-UPS ES 350 - UPS ( external ) -...

1 Answer

Less back up time


I found the following on APC's web-site for the APC Back-UPS, this will hopefully fix the problem:
You can also perform a manual runtime calibration. This could be done if you have changed your equipment load or battery. Stop the PowerChute software from running; disconnect the serial cable between the computer and UPS. Next unplug the UPS from the wall and let it run on battery until it reaches low battery. Once it reaches low battery plug it back into the wall outlet and let it recharge. Recharge time can take up to 4 hours.


from link: http://nam-en.apc.com/cgi-bin/nam_en.cfg/php/enduser/std_adp.php?p_faqid=2819&p_created=1048797826&p_sid=tANR-rxj&p_accessibility=0&p_redirect=&p_lva=&p_sp=cF9zcmNoPTEmcF9zb3J0X2J5PSZwX2dyaWRzb3J0PSZwX3Jvd19jbnQ9NCw0JnBfcHJvZHM9MCZwX2NhdHM9JnBfcHY9JnBfY3Y9JnBfc2VhcmNoX3R5cGU9YW5zd2Vycy5zZWFyY2hfbmwmcF9wYWdlPTEmcF9zZWFyY2hfdGV4dD1yZWNhbGlicmF0ZQ**&p_li=&p_topview=1


Mar 31, 2009 | APC Back-UPS RS 800VA UPS System

1 Answer

Common Failure mode of APC 500 UPS


I would recommend replacing APC UPSs with ONEAC ONEPlus Power Conditioned UPSs, which have a perfect ground reference, longer lasting and more reliable batteries, and a 5 Year Warranty (2 Yrs on Batteries).

www.gryphon-inc.com

1-800-POWER-OK

Dec 04, 2008 | APC (BH500NET) UPS System

3 Answers

APC back UPS 400 fails to give back up


I have the same problem with an apc smart-ups VS 650.

 

New batteries - charge in batteries is good (also tested under load).

 

When AC power fails, no power is supplied to PC connectors by the UPS.

 

UPS self test works fine. UPS does not report any problems via software - Power Management under Windows XP.

Oct 12, 2007 | APC Back-UPS 400VA (BK400) UPS System

Not finding what you are looking for?
APC (BE500U-WEB) (BE500UWEB) UPS System Logo

Related Topics:

200 people viewed this question

Ask a Question

Usually answered in minutes!

Top APC UPS Battery Backup Systems Experts

Cindy Wells

Level 3 Expert

4755 Answers

Jax Planet
Jax Planet

Level 2 Expert

921 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Are you an APC UPS Battery Backup System Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...