Question about LG Art Cool LA121CNP wall/window Air Conditioner

1 Answer

Lg Art Cool

My Art Cool stops after being on only 30 seconds, no error codes?

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Prodigy:

    An expert who has answered 500 questions.

  • Expert
  • 540 Answers

Checkout the manufactures specs and model # on the webpage!

Posted on Sep 03, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What is the corrective action for error code 46?


Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor

Jun 23, 2015 | LG Art Cool LA240HSV 22,000 BTU SingZone...

1 Answer

Have an lg dfs unit not working cooling lamp flashes 7 times heat lamp 6 times what is the problem?


DEFINING COMMON ERROR CODES www.lg-dfs.com/.../dfs-tp-ag-002-us_012h29_lgtechpaper_errorcodes-la... Aug 29, 2012 - Refer to Service Manuals posted on www.lg-dfs.com to troubleshoot individual error codes. Error. Code. Description. No. of Times Indoor Unit ...

Mar 02, 2015 | LG LSN121HSV LSU121HSV 1 Art Cool Ductless...

1 Answer

C9 error code lg cool art


let the technicians do it for you,one of their sensor got faulty

Apr 21, 2014 | Air Conditioners

1 Answer

Lg split system ch 46 error? help!!!


Ch-46Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor

Jan 07, 2011 | LG Art Cool LA181CNW Split System Air...

1 Answer

LG Art Cool, 2 splits. Error code CH7


Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear.
Splits = Compressor Over Current (CT2)

Jul 09, 2010 | LG Art Cool LA121CNP wall/window Air...

1 Answer

LG Art Cool Error Code CA


Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Replace sensor.

May 04, 2010 | LG Art Cool LA181CNW Split System Air...

1 Answer

Error Code on LG Art Cool


error code CH22 is either compressor or inverter fault.

Jun 01, 2009 | LG Art Cool LA091HNP Split System Air...

1 Answer

LG error CH 64


What is the model of the unit?

Apr 07, 2009 | LG Art Cool LA121CNP wall/window Air...

3 Answers

Ch 5 error code


ch5 error code, means that there is a
communication error (serial comunication) between the outdoor and the indoor unit.
Only for LG-airconditioners.

Jan 02, 2009 | LG Art Cool LA121HNP Split System Air...

2 Answers

Lg ductless no ac


I may not be of much help but I may be able to guide you into some diagnosos. If there is a communication problem between the inside and outside unit, both on the inside and outside units a colored LED will bling 5 times then pause for 3 seconds. The 33 and 44 codes are confusing to me because I have never seen this. Try resetting the outside unit with no call for heat or cool from the inside unit. After about 20 seconds, restore power to the outside unit. Go in and turn on the remote and make sure you lower the cool setting more than degrees cooler than the room temp. After 3 minutes the outside unit should turn on. If you get an error code of either 1, 2 or 5 blinks document it for the technician. If you continue to get your 33 and 44, you have a bad control board. If all else fails, press and hold the button located on the lower left side of the art unit and hold for about 5 seconds. If it still no longer works, now you will need the help of someone who knows these units.

Sep 08, 2007 | LG Art Cool LA121CNP wall/window Air...

Not finding what you are looking for?
LG Art Cool LA121CNP wall/window Air Conditioner Logo

Related Topics:

352 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Air Conditioners Experts

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Are you a LG Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides