Operation light is red and my Fujitsu split type air conditioner is drippy and icing up. model asu1201 serial AJA006007

Most likely low on refrigerant. This will cause the evaporator to ice up which will then drip in side the room as the outer surface melts. It also causes less air flow through the heat exchanger which exacerbates the problem. You need to find the source of the leak which is probably at one of the flare joins. Unfortunately, I don't have a service manual for this model so cant tell you what the error code is. Consult a local tech.
7/14/2014 9:20:13 PM • Fujitsu 24C1 Air... • 161 views • 0 helpful votes
0helpful
1answer

Clean mold out of air conditioner

6/25/2014 11:32:13 PM • Fujitsu 24C1 Air... • 213 views • 0 helpful votes
1helpful
1answer

Fold rear seat rimot not work

Kya muskil chalrahe bay? Dushra remote kushish kartaje.
7/7/2014 3:17:41 PM • Fujitsu 24C1 Air... • 59 views • 1 helpful votes
0helpful
1answer

Error communication btw indoor-outdoor units

The thermostat is the only communication between indoor and outdoor units.
11/30/2013 1:55:05 PM • Fujitsu 24C1 Air... • 7,782 views • 0 helpful votes
0helpful
1answer

Compressor won't come on I want to by pass thermostat

First check power or (high voltage) to outside unit if good make sure you have thermostat voltage or (low voltage) to the outside unit.
2/9/2014 12:39:58 AM • Fujitsu 24C1 Air... • 47 views • 0 helpful votes
0helpful
1answer

Water leaking from inside unit

drain line clogged is the most common, possible rusted out or cracked drain pan. cooling fine?
1/20/2014 3:55:46 AM • Fujitsu 24C1 Air... • 64 views • 0 helpful votes
0helpful
1answer

I have a fujitsu floor mounted heat pump. The

My friend your air con has problem and the problem is the freon. You must add the right quantity.
10/5/2013 11:04:41 PM • Fujitsu 24C1 Air... • 669 views • 0 helpful votes
0helpful
1answer

Air con wont start up. ? Flat battery

Should be a couple of tiny Phillips.
12/13/2013 4:27:41 AM • Fujitsu 24C1 Air... • 86 views • 0 helpful votes
0helpful
1answer

Eco-487L w-1

Is it plugged in?
1/12/2014 6:25:24 PM • Fujitsu 24C1 Air... • 38 views • 0 helpful votes
0helpful
1answer

Remote control model AR-DL10 does not work even

The reset button on the AR-DL10 is the 'ACL' button. On my unit it is just above the Start/Stop button. On some of them it is in the battery compartment.
8/15/2013 10:35:23 PM • Fujitsu 24C1 Air... • 721 views • 0 helpful votes
0helpful
1answer

Cannot turn on the appliance using the controller ? flat battery

Yes, replace the battery.
12/13/2013 4:24:49 AM • Fujitsu 24C1 Air... • 30 views • 0 helpful votes
0helpful
1answer

Musty smell from unit

That smell is from the condensate (water). Clean the inside of the unit with bleach and pour some down the drain plumbing .
9/26/2013 12:56:48 PM • Fujitsu 24C1 Air... • 194 views • 0 helpful votes
0helpful
1answer

Fujitsu ASY12RSE-W. Unit not working at all. Timer

It's showing an error code for the outdoor unit no communication from the outdoor circuit board.
7/30/2013 3:17:49 PM • Fujitsu 24C1 Air... • 637 views • 0 helpful votes
0helpful
1answer

Fijitsu halcyon inverter smells moldy and spit out black stuff looks like mildew

Needs a clean out . Get it serviced
4/16/2013 2:04:53 AM • Fujitsu 24C1 Air... • 984 views • 0 helpful votes
0helpful
1answer

Where can I get a manual?

http://www.fujitsugeneral.com/PDF_06/2005Documents/OwnersManuals/OpManLargeWallAC&HP.pdf
6/25/2013 12:32:39 PM • Fujitsu 24C1 Air... • 77 views • 0 helpful votes
0helpful
1answer

Remote

6/17/2013 2:54:46 PM • Fujitsu 24C1 Air... • 83 views • 0 helpful votes
1helpful
2answers

Fujitsu airon ASTA24LCC 2 flashes green and red then 5 red flashes any idea what it means

Had similar problem (ie. 2 green & red flashed followed by 5 red flashes - Fan blowing but not cooling ... I also noted that the outside unit fan wasn't going). Tried restarting several time after waiting only a minute or two after turning the mains power off but with no change. So turned the unit off at the mains power and then fired it up about 2hrs later and it was all working fine.
1/24/2013 7:40:32 AM • Fujitsu 24C1 Air... • 1,700 views • 1 helpful votes
0helpful
1answer

I have a Fujitsu ASU24CL1 and after a loss of power we now have no A/C. Fan works but the red and green lights flash 5 times then go off for a short time then flashes again ?

Seems like a problem with ur condenser power wiring, check diconnect, line from breaker should be in line and line goin to cond should be on load
7/1/2012 12:16:35 PM • Fujitsu 24C1 Air... • 466 views • 0 helpful votes
Not finding what you are looking for?
Fujitsu 24C1 Air Conditioner Logo

253 questions posted

Ask a Question

Usually answered in minutes!

Top Fujitsu Heating & Cooling Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you a Fujitsu Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Fujitsu Heating & Cooling

  • Fujitsu Heating & Cooling

Most Popular Question

fujitsu airon asta24lcc 2 flashes green

  • Heating & Cooling
Loading...