Hello, I have a new LG PTAC heat pump, LP120HED-Y8. I also installed the optional wireless remote...
(More)
Hello, I have a new LG PTAC heat pump, LP120HED-Y8. I also installed the optional wireless remote thermostat, PYRCUCCOA. During cooling mode it worked great, now that it has cooled and I am needing the heat, it is acting very strange. It has two stages of heat, compressor and heat strips. Upon setting the thermostat at a higher temp, engaging the second stage it heats great. When it reaches near the room setting it then activates the compressor, then it shuts down. Then when it calls for heat the next time it appears to be trying to defrost. This is what happens: 1. unit turns on normally, compressor running and fans running and heat is coming out. 2. after about 45 seconds the unit shuts off. 3. about three minutes later, the compressor turns on, neither fan running. the system is then in cooling mode as inside coil is cold. 4. runs in this manner for several minutes, then the compressor shuts down, and the outside fan turns on and runs for a few minutes. Then it shuts off, and you can hear the reverse valve shift, and then the unit turns on, heating as if nothing is wrong. It does this almost every time it calls for heat and takes approximately 12 minutes to start heating. The remote thermostat is activated by one of the DIP switches on the control board, so I can turn it to the position where it uses the onboard thermostat, and it heats normally so my problem lies in the remote thermostat, board, or how I have it set up. The instructions that came with the stat were horrible. I have called into LG twice, and haven't yet been able to speak to a tech who is familiar with this system. Anyone heard of this problem, or know how these systems are supposed to work, and mostly what the proper settings in the touch screen thermostat are that might cause this? Thanks so much, John
I had this fellow ask why he couldn't find any thing about id model number for buying a replacement out door ac unit. The answer I game him is part...
written by farfield
Typically if you want a circuit completed when energized you use C (Common) and NO
(normally open). This means that the contact will close when...
written by farfield
A low charge diagnosis for instance can be miss read if the evaporator
is iced up or has any ice in or on it. A sticking thermostat, relay,
or...
written by farfield
What I have always been told is if your 24 volt side burns out check
the high volt side if the hi volt side burns out check the low volt
side. A...
written by farfield
If your wondering how to check out your refrigeration
compressor;
Modern Compressors have two operations that have to work
together just to run....
written by farfield
Examine the air filter at the beginning of each cooling and heating season and at the beginning of each day light savings time change. Write the date...
written by farfield
Suffering in summer heat in the upstairs bedroom? Make the most of the air conditioning by following these steps.
Steps:
1. Add attic insulation....
by wikihow
If your tap water is cool, you can air condition a room with it at minimal cost.
Steps:
1. Obtain a radiator from a small car such as a Honda Civic,...
by wikihow
Steps:
1. Change your filter regularly. This simple step alone can increase the efficiency of your air conditioner. It will also run less, increasing...
by wikihow
Service and Repair, System Maintenance, Advantage Mem... Read More