20 Most Recent
Viking 37 in. VGSU163-6BBK-LP Gas Cooktop Questions & Answers
The glass of the electric cook top is lifting from the stainless steel frame
www.
vikingrange.com/.../m10103_
viking_built-in_surface..
Viking RangeFortunately, our built-in rangetops, cooktops, and gas woks offer the ... sealed or open burners, every Viking gas rangetop delivers unrivaled ..... The only thing cleaner than the glass ceramic surface of Viking electric cooktops is the installation.
My Viking Range top has 4 burners and the
Sorry to read about your problem, I hope this helps you out.
your lite tube may be clogged, or take a needle and clean the hole's next to the lite tube on the range grills..
I tried to help you. Please help me and Rate/Vote on my response, thanks and good luck
We have a viking cook
Hi,
Some units have a dead man switch, which means that if the filters are not in place correctly the blowers will not operate. Its a safety thing to prevent little ones from dropping toys into a running blower. Double check the filters placement, if the filters are in the proper location than I would look at the power to the blower unit. The vent has two jobs, (1) to raise and lower, (2) to turn on the blower unit once in the full up position. If this is not the case, the upper switch in the vent system has failed. If you already confused, you will need to call a Viking expert to correct this problem. Its not difficult but can be time consuming.
I hope this helps
I have seen this problem twice and found the filters were the problem, rarely replace blower motors.. I’m happy to help further over the phone at
https://www.6ya.com/expert/gere_bf68e6055dd61249
I have a six burner
there is the possiblity that you have a switch that is stuck as well i had a ge cafe that when you turned on one burner all burners would spark after along process of replacing the spark modulator and every ignitor in the unit i used a voltage meter on the wiring and found that power was going past one switch to the ingitor when the switch had red that it was off after taking the switch apart i had found that on the inside of the switch the mteal contact at one point had arched and was fused to the other side so when you turned on any switch the power would also run through that switch that even though it showed it was off it was still on on the inside of the switch if you are not used to conducting electrical tests on an appliance i would ask that you call a technician this is a very elaborate testing process and should not be carried out by a non trained indiviual if you have any further questions message me back and when we conclude this chat please remember to rank how this opinion has helped as well thanks again
Rick
We have a 36" sealed-burner
Hi,
As this is not a problem with all he 4 burners, this would mean the ignition control module is fine. I seems to be an issue with ignitor switch or ignitor themselves. Sometimes, it could be due to wiring harness.Try
wiggling all of the ignitors first, pulling them away from the burners.
Pulling up on them a bit makes them easier to wiggle and see, if that helps.
You could use it until the service comes. However, my advise would be to call a professional as soon as possible as if it might be a harness problem and could cause the same issue to the other 2 burners. DO NOT light the burners with a match.
Let me know,if needed further assistance.
Hope i helped you.
Thanks for using ' Fixya ' and have a nice day!!