HV TRANSFORMER
Remove lead wire.
Measure the resistance of the winding using an ohm meter
Primary winding 3 ohm (approx.)
Secondary winding 100 ohm (approx.) Filament winding 0 ohm (approx) HV CAPACITOR Remove lead wire Measure the resistance using an ohm meter set to R*1000 Terminal to terminal should momentary indicates several ohms but gradually increases to infinite. Terminal to case should show infinite.
MAGNETRON Remove lead wire. Install the magnetron gasket in the correct position. Check that the gasket is in good condition. Measure the resistance of the filament terminals. Normal magnetron should be less than 1 ohm. Measure the resistance between the filament terminal to chassis. Normal magnetron should be infinite.
HV CAPACITOR
Remove lead wire
Measure the resistance using an ohm meter set to R*1000
Terminal to terminal should momentary indicates several ohms but gradually increases to infinite. Terminal to case should show infinite.