Amana PTH153B35AE Air Conditioner - Answered Questions & Fixed issues

0helpful
8answers

Amana PTAC

I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you set on the control panel is within 2-1/4 degrees (or 4 degrees depending on your unit model. Otherwise, the unit locks out the compressor until the electric heat coil bring the indoor temperature up to that level - and then will switch the compressor back on for heat pump operation. So the problem is not the control panel or the compressor, it the electric heat coil. The coil has two manual limit switches on it that may be tripped and should be checked. The coil can be easily accessed by shutting down the power, removing 4 screws around the air outlet, pushing the screen up and sliding the panel out the top. The power wires can remain in place while the limit switches are reset. Hope it works.
4/20/2020 9:29:19 PM • Amana... • Answered on Apr 20, 2020 • 22,060 views
0helpful
1answer

Unit comes on with switch in off position

sounds like your switch dial is backfit try pull it out and reset it back the right way
1/14/2011 11:10:37 PM • Amana... • Answered on Jan 14, 2011 • 89 views
0helpful
1answer

I have an electric fire and it was working fine

Your question is worded strangely, did you have an electrical fire in the unit? My guess is that you have not kept the filter clean and now you need to take it to a service company for the replacement of the heater's fuseable link.
10/9/2009 8:42:58 PM • Amana... • Answered on Oct 09, 2009 • 433 views
0helpful
1answer

The unit has quit cooling. The compressor does not seem to be coming on.

check thermostat contacts, possibly not sending signal to pick up
6/2/2009 2:09:34 PM • Amana... • Answered on Jun 02, 2009 • 286 views
0helpful
1answer

Heater blowing out cold air

Yes you could have a bad overload on the heater element which is fairly simple to fix. To test for this pull the heater out and get an ohmeter set it to continuity and check the continuity first through the entire heater element then if there is none pin point the overloads and check to see which one has no continuity.
12/7/2008 9:40:35 PM • Amana... • Answered on Dec 07, 2008 • 2,512 views
0helpful
1answer

What if I replace 1/3 blower motor with 1/2 motor on Amana 80 SSE Furnace?

The important consideration is the rotational speed and adding extra horsepower really doesn't achieve anything because the motor isn't really under 'load' as it would be in say a winch. It is better to stick to OEM Specs https://www.google.com/search?q=amana+80+sse+blower+motor ..
2/6/2024 5:18:53 AM • Amana Heating &... • Answered on Feb 06, 2024 • 21 views
0helpful
1answer

Amana DigiSmart PTH153B50AM 14000 BTU Heat Pump. What Amana model replaces PTH153B50AM please?

Question edited for a lot more clarity. The new improved energy efficient versions.

The Improved Amana R-410A PTAC Unit Uses Less Energy

Amana PTAC https://www.amana-ptac.com > products > ptac Looking to buy an energy-efficient PTAC unit for your building? Buy the new Amana R-410A PTAC unit heat pump, which reduces energy consumption by 35%. Probably this one. Talk to your installer. https://www.amana-ptac.com/products/ptac/hec154j ..
1/10/2024 5:01:34 AM • Amana Heating &... • Answered on Jan 10, 2024 • 22 views
0helpful
1answer

Amana PTAC air conditioner. Switch to a wall thermostat?

Question edited for clarity and toss in some CAPS. You can get wired or wireless. https://www.amana-ptac.com/products/ptac Fitting https://www.google.com/search?q=amana+ptac+connect+to+wall+thermostat .
7/26/2023 3:29:14 PM • Amana Heating &... • Answered on Jul 26, 2023 • 53 views
0helpful
1answer

I'm not getting any code after installing a control board for my Amana ptac?

Does the power light come on? If yes, then you can do a reset as below: There is a master switch on the bottom left of the control board. Slide that to 'off' position. Then press the hot and cold switch/key together and then slide the master switch back to 'on'. Please put your response/observation here if that does not work or there is power light as asked on top. Thanks
2/27/2023 3:44:12 PM • Amana Heating &... • Answered on Feb 27, 2023 • 213 views
0helpful
2answers

Amana PTH153B50AM PTAC where the heat runs intermittently.

i'm not familiar with your specific unit but ..sounds like an electronic gas value has gone bad or has a bad connection when that happened to my friend it wasn't that expensive to have it fixed .. BYW it acted like this for a while then stopped working completely
1/23/2023 9:58:51 PM • Amana Heating &... • Answered on Jan 23, 2023 • 95 views
0helpful
1answer

Amana window ac unit fan continues on and how to reset the unit

Hi, Please hit the "constant fan" button until the "on" button is removed from your Amana screen. Thank you.
10/24/2022 8:10:04 PM • Amana Heating &... • Answered on Oct 24, 2022 • 57 views
0helpful
1answer

Amana air command red light is on and it says to replace control . what control?

bad control board
10/19/2022 2:35:32 AM • Amana Heating &... • Answered on Oct 19, 2022 • 53 views
0helpful
2answers

Amana ptac blower wheel not turning on , compressor and fan are working

blower capacitors or motor bad
9/28/2022 2:39:50 PM • Amana Heating &... • Answered on Sep 28, 2022 • 126 views
0helpful
2answers

Amana pth153g35axxx in wall system and it is blowing air only we reset it and still not blowing any cold air, what causes this the system sound like it is running correctly but no cold air

you will need to call for service. if it needs freon you cannot recharge it freon is expensive and requires a license.
9/12/2022 5:42:17 AM • Amana Heating &... • Answered on Sep 12, 2022 • 112 views
0helpful
2answers

I have an Amana AP148D, can I run it without an

Self evaporating simply means there is a drain pan with a heater device installed that will evaporate and condensate that drains from the unit into the pan.

You do not need the external drain pan unless the unit makes more water than the drain pan and drain pan heater can handle.
5/29/2022 4:56:06 PM • Amana Heating &... • Answered on May 29, 2022 • 537 views
0helpful
1answer

How to configure AMANA to only use the heating element and not the pump?

switch thermostat to emergency heat. Call for service the unit should be under warranty. Be aware that using heating strips will cause your electric to go extremely high.
12/18/2021 8:22:05 PM • Amana Heating &... • Answered on Dec 18, 2021 • 60 views
0helpful
2answers
Not finding what you are looking for?
Amana PTH153B35AE Air Conditioner Logo

9 questions posted

Ask a Question

Usually answered in minutes!

Top Amana Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you an Amana Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...