bad temp sensor

Dometic CS-200... | Answered on Oct 14, 2017 | 100 views


check temp sensor inside fridge see if it fell into pan

Dometic CS-200... | Answered on Oct 03, 2017 | 139 views


check voltage if too low will mess with control panel

Dometic CS-200... | Answered on Jun 03, 2016 | 56 views


If the back of the refrigerator is getting warm and the refrigerator is level then you more then likely will require a replacement cooling unit. You can visit our online Store or give us a call directly 1-888-782-6665 We ship throughout North America!
22379ebf-f0d9-457f-a035-f4a5f979a633.jpg

Dometic CS-200... | Answered on Sep 24, 2014 | 74 views


make sure motor home is level

Dometic CS-200... | Answered on Jul 27, 2009 | 209 views


If your cooling unit is gurgling, then you have air in the system or a bad cooling unit. There is a process known as "burping" that should help repair this. It is a rather lengthy process and will require two people.

1. Access the rear of the refrigerator. Turn off the LP gas to the unit. Remove the LP Gas line and the 12Volt supply. Unplug the fridge.
2. Remove the screws in the rear at the bottom and then remove the screws from the inside.
3. Pull the fridge out and lay it down on it's right side for 8 hours.
4. Flip the fridge on it's top for 8 hours
5. Now the left side, then back to normal.
6. Reinstall the fridge and turn gas back on.

Hope this helps,

Jeff

Dometic CS-200... | Answered on Jul 08, 2009 | 922 views


try checking fusible links if ok try with thermistor unplugged if ok replace

Dometic... | Answered on Aug 12, 2018 | 126 views


thermal coupler is probably bad, the igniter will spark and the gas will be there until you release the igniter button.

Dometic... | Answered on Aug 12, 2018 | 37 views


check fuses on control board if blown check electric heater element

Dometic... | Answered on Aug 12, 2018 | 38 views


there is not one

Dometic... | Answered on Aug 05, 2018 | 36 views


Yes, I would check your venting. Shut it down and open the access to the back of the fridge. The venting should be apparent and clean of course. Propane has a high water vapor content and contains Carbon Monoxide and should not be burned unvented in small spaces. Good Luck

Dometic... | Answered on Jul 28, 2018 | 50 views


check fusible links if ok unplug thermistor let run if cold replace if not possible bad control board or cooling unit see if chimney hot if hot bad cooling unit

Dometic... | Answered on Jul 28, 2018 | 52 views


compressor thermo fuse resets it self

Dometic... | Answered on Jul 28, 2018 | 133 views


have another tech look at it because he would know would need a tap a line to do pressure readings and add freon --as to reverse polarity that would hurt vehicles or battery operated type equipment as to house hold it would be the the low out put voltage that would damage equipment

Dometic... | Answered on Jul 23, 2018 | 31 views


check burn tube and gas pressure also check for lint or debris in back

Dometic... | Answered on Jul 08, 2018 | 33 views


possible loud fan motor if it has fans up in back

Dometic... | Answered on Jul 08, 2018 | 42 views


check fusible link on back wall by chimney if ok bad control board

Dometic... | Answered on Jul 08, 2018 | 75 views

Not finding what you are looking for?
Dometic CS-200 Wine Cooler Logo

9 questions posted

Ask a Question

Usually answered in minutes!

Top Dometic Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4655 Answers

Charles T Nevin
Charles T Nevin

Level 3 Expert

4070 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22359 Answers

Are you a Dometic Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...