Haier mini split E7 and exterior fan not working
On a Haier Split system a E7 error is a failure of the outdoor inverter PCB and the outdoor power supply PCB. Both will need replacing. Looking around $600 for those parts. Plus fitting. The indoor PCB is very unlikely to be needed.
Where is the drain hole
Hello, some window units do not have a drain hole for the condensate, instead the use the fan blade to sling the water on the condenser, since the condenser is warm/hot it will evaporate the condensate.
E1 on haier thermocool side by side refrigerator
That error is a freezer fan motor error, Check to see if the unit is defrosting like it is supposed to be. IF it is defrosted, check to see if the motor spins and if you have a meter for measuring resistance, check the motor windings. If they show no conductivity, Replace the fan.