<?xml version="1.0" encoding="us-ascii"?><rss version="2.0"><channel><title>GE Quiet-Aire Ductless Air Conditioning Split System, AS1CD12AA0/AS0CD12AA0 Air Conditioner Support</title><link>http://www.fixya.com/support/p478871-ge_quiet_aire_ductless_air_conditioning</link><description>Solved  technical support problems provided by FixYa users.</description><language>en-us</language><copyright>Copyright (c) 2007  FixYa, LTD.  All rights reserved.</copyright><webMaster>info@fixya.com</webMaster><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate><ttl>80</ttl><item><title>When I cool the room it doesn't drop to the</title><link>http://www.fixya.com/support/t3558044-when_cool_room_doesnt_drop</link><description>When I cool the room it doesn't drop to the temperature I have it set to but a few degrees celcius higher. Is that normal? I honestly never checked on my old unit but this one doesn't seem to feel as cool.</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>MY RAMSOND MINI SPLIT HIGH PRESSURE LINE IS FROZEN</title><link>http://www.fixya.com/support/t3201406-ramsond_mini_split_high_pressure_line</link><description>MY RAMSOND MINI SPLIT HIGH PRESSURE LINE IS FROZEN EVERY TIME I TURN THE UNIT ON</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Wiring diagram for Ramsond 18000 BTU Ductless</title><link>http://www.fixya.com/support/t2520732-wiring_diagram_ramsond_18000_btu</link><description>Wiring diagram for Ramsond 18000 BTU Ductless split system. outdoor unit wiring diagram G 1 2 3 N L L N G. The first 6 terminals are interconnection to indoor unit. The last three terminals , L N G, are indicated for power supply. 240v power supply...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>1994 mountainaire motorhome AC</title><link>http://www.fixya.com/support/t2715528-1994_mountainaire_motorhome_ac</link><description>We have a moutain aire motorhome with 2 dometic ac units in it. they seem to have packed it in the power comes on the lights are on but nothing happens they do not kick in, can these units be repaired and if so can you recomend someone in the langley...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Water leak on the left side of the unit</title><link>http://www.fixya.com/support/t2708390-water_leak_left_side_unit</link><description>After running for a while there is a water leak on the left side of the unit and also there is excessive condensation on the liquid line. My question is how do you recharge this to the correct refrigerant charge. Can you use the superheat system or...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>MY split ac is leaking water from the wall unit, it has been doin</title><link>http://www.fixya.com/support/t2707314-split_ac_leaking_water_from_wall_unit</link><description>this for the past few weeks, then it stopped, then started leaking gradually again. not sure what it is, i thought it was the filters so i cleaned them, but to no avail.</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>1990 Dolphin Motorhome Dometic AC problem</title><link>http://www.fixya.com/support/t2569076-1990_dolphin_motorhome_dometic_ac</link><description>I have a 1990 Las Brisas Dolphin Motorhome. For the last 2-4 days it has been losing certain speeds on the fan. Recently it also cools for a short period of time, makes a fairly loud noise and then the compressor kicks off and it only blows hot. Is...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>The outside unit is making a squealing noise. It's</title><link>http://www.fixya.com/support/t2445655-outside_unit_making_squealing_noise_s</link><description>The outside unit is making a squealing noise. It's every now and then; not constant. Just started today. What's wrong? The fan is running fine. The air inside is cool. Just a high piercing squeal every now and then from the outside unit. Any ideas?</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>remote control signal to multi or split air conditioner, samsung</title><link>http://www.fixya.com/support/t2400746-remote_control_signal_multi_or_split_air</link><description>I cannot use the remote control to activate the unit. I have ck. batteries and turned off power for a period of time. The remote shows all icons and the icon to indicate the signal is sent. I can operate the unit otherwise with the buttons on the...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>I am concerned the wiring diagram provided for a</title><link>http://www.fixya.com/support/t2241101-am_concerned_wiring_diagram_provided</link><description>I am concerned the wiring diagram provided for a Ramsond 12000 btu split system 240 volt is wrong.  (1 2 3 N L L N)  I assumed the L's were slots for the hot legs.</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>ramsond a/c trouble code E7</title><link>http://www.fixya.com/support/t1392546-ramsond_c_trouble_code_e7</link><description>E7 in the maintenance book stands for external feedback fail. what is the external feedback?</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>panasonic cs-pw9gke i need wiring diagram</title><link>http://www.fixya.com/support/t1337745-panasonic_cs_pw9gke_need_wiring_diagram</link><description>hi i need wiring diagram for cs-pw9gke split a/c, i want to know how many cables you need to connect the indoor with the outdoor unit. CLIMAINVEST FROM RODOS GREECE THANK'S</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>how panasonic charging by superheat</title><link>http://www.fixya.com/support/t1823800-panasonic_charging_superheat</link><description>how panasonic charging by superheat</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>The inside unit makes a squealing noise when it</title><link>http://www.fixya.com/support/t2008114-inside_unit_makes_squealing_noise_when</link><description>The inside unit makes a squealing noise when it first starts.</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Timer</title><link>http://www.fixya.com/support/t471088-timer</link><description>Can anyone explain how to use the timer of the GE split system?</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>GE mini-Split  Error code</title><link>http://www.fixya.com/support/t708094-ge_mini_split_error_code</link><description>I am currently trying to diagnose an error code on a ge mini split model number AS1RD18DA0G1 (this is a unit from the year 2000) on this system,on a call for cooling,the indoor unit opens the louvers,the fans do not start,nor does the outdoor section...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>panasonic split systems</title><link>http://www.fixya.com/support/t1459272-panasonic_split_systems</link><description>where i can find panasonic split system parts</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>My GE ductless system is not heating properly and trips breaker</title><link>http://www.fixya.com/support/t1336896-ge_ductless_system_not_heating_properly</link><description>My system trips the breaker and the fan on the inside unit will not blow when in the heat mode. Fan is working as it runs for air and dehumidifying modes. Was told that the overload needs replacing but GE will not give tech advice to my service guy...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>moving ductless compressor unit</title><link>http://www.fixya.com/support/t1085622-moving_ductless_compressor_unit</link><description>CAN I DISCONNECT THE REFRIGATION LINES TO MOVE THE OUTSIDE UNIT TEMPORARY OR DO I LOOSE THE FREON</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Ramsond split AC 12000</title><link>http://www.fixya.com/support/t998498-ramsond_split_ac_12000</link><description>I installed it in July-08. It worked for few days with water leakage from starting point( inner unit). The flow level was perfect and i couldn't figger it out the fault. Now it stopped working no cooling atall showing error E4 ? Pls advise.</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Help!!</title><link>http://www.fixya.com/support/t991763-help</link><description>Our unit is draining on the inside and dripping on the floor, it has stopped draining outside. We have been running the ceiling fan a little while unit was running I do not know if that had something to do with the problem. Thanks, Debbie</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>compressor not starting</title><link>http://www.fixya.com/support/t912827-compressor_not_starting</link><description>compressor drawing 150 ampers and tripping out .but coil not contenuity to ground. suspect bad compressor but cannot rule it out.</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>coils freezing up!</title><link>http://www.fixya.com/support/t658658-coils_freezing_up</link><description>The refrigerants is related to a system preassure and temperature relationship! If too low preassures the refrigerant cools too low.. If just right it will stay above freezing temperatures ((32*)) If too high of a preassure, or too much refrigerants...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>new install. 40 seconds on. 20 seconds off.</title><link>http://www.fixya.com/support/t426849-new_install_40_seconds_20_seconds</link><description>Just installed a ductless mini split. When in heat mode the unit turns on for 40 seconds then shuts off for 20 seconds. Keeps rerunning that cycle. The air comming out is warm....</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>20 year old central a/c heater not working</title><link>http://www.fixya.com/support/t332448-20_year_old_central_c_heater_not_working</link><description>I have an old house, my central unit heater is not working blows cold air not hot air when i need it. Is a GE unit, dont know the model</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Furnace burners wait too long to come on</title><link>http://www.fixya.com/support/t212204-furnace_burners_wait_long_come</link><description>Furnace wait too long to come on and then comes on with big booh and after 5-10 minutes burners and pilot goes off together.
I already change the thermocoupler. any advise?

Mitchell Manuf. Model 75-AGCF
s/n- f1-113</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>whirlpool acq088mro air conditioner</title><link>http://www.fixya.com/support/t226730-whirlpool_acq088mro_air_conditioner</link><description>the red light stays on in the front panel.  we do not have a manual and cannot figure it out.

can we get a manual?</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>Blower won't stop runing.</title><link>http://www.fixya.com/support/t232376-blower_stop_runing</link><description>Recently a new blower motor was installed,is working fine but it never stops,is runing all the time weather outside unit is runing or not;what you think is the problem?</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>PORTABLE A/C</title><link>http://www.fixya.com/support/t232598-portable_c</link><description>COND. FAN MOTOR ON PORTABLE A/C RUNS OFF AND ON, ONLY WHEN THE MOTOR IS COOL IT RUNS, BUT WHEN ITS HOT DOES NOT RUN. BUT WHEN I FORCE IT TO RUN WITH HAND IT RUNS FOR A WHILE. I KNOW THAT THE CAPACITOR IS STILL GOOD. I JUST WONDERING IF I NEED A NEW...</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item><item><title>hisense air conditioner</title><link>http://www.fixya.com/support/t233774-hisense_air_conditioner</link><description>compressor on air conditioner runs for 5 seconds then cuts out,after a few minutes cuts back in, runs for 5 seconds and then turns off airconditioner.after minute or two cuts back in compressor runs 5 seconds cuts out and so on</description><pubDate>Wed, 06 Jan 2010 16:50:02 GMT</pubDate></item></channel></rss>