Removal of Pump
(a) Lay machine on an angle against a wall. If
leaning the machine against a wall ensure
that the machine is stable,
and take necessary precautions
not to damage the wall or the machine.
(b) Remove the wiring harness to the pump and the earth wire.
(c) Release the locking tab by pulling it away from the pump.
Keep pressure on the tab and turn the body of the pump in an anticlockwise direction.Continue to turn until the pump disengages.
Note: Approximately 250mls of water remains in the pump sump after pump out and will spill when the pump is removed.
Take care not to spill this water over electrical connections by using a towel or small container to catch the water.
Reassembly:
(a) Locate the bayonet fixture correctly, then turn the pump in a clockwise direction until you hear the locking tab clicks into place.
(b) Connect the earth wire ensuring that the tab is locked into place by applying gentle pressure on the wire.
(c) Connect main harness.
Ensure that the wiring is routed correctly and will not foul on any
moving components.