Beverage-Air MT27 Beverage Cooler Commercial - Answered Questions & Fixed issues

0helpful
1answer

My commercial refridgerator stays too cold

Defective cold control thermostat
11/2/2017 1:33:55 PM • Beverage-Air... • Answered on Nov 02, 2017 • 213 views
0helpful
1answer

I have a 7 yrs old beverage air mt27. The issue

That temperature control assembly will most likely be the problem.
10/10/2017 11:49:22 PM • Beverage-Air... • Answered on Oct 10, 2017 • 276 views
0helpful
1answer

MT27 has a noisy fan operation. Doesn't always

There are a couple of possibilities that could be causing this. I believe it is the fan blade. One could be that bracket that holds the fan motor in places could have loose screws, which would cause vibration. Another is that the mounting for the fan motor to the bracket could be loose. Another could be that the fan blade itself is slightly bent. Check the motor brackets screws, fan mounting screws and the blades. If all those are good, making sure the unit is unplugged you can turn the fan blade by hand slowly to see if it is dragging anywhere on the shroud around the coil or the coil itself. You could slightly bend the "clacking" blade to clear is that is the issue. Tom
10/8/2017 5:36:42 PM • Beverage-Air... • Answered on Oct 08, 2017 • 256 views
0helpful
1answer

Can i use a beverage air mt27 as a freezer

Nope, You Can not. Compressors for freezers are different and if it set up as an fridge, you will not have enough defrost (on freezers there are heaters)
8/11/2016 4:47:15 AM • Beverage-Air... • Answered on Aug 11, 2016 • 285 views
0helpful
2answers

I have a Beverage Air

Thats How To Replace Compressor on Beverage Air.
9/28/2020 6:13:01 AM • Beverage-Air... • Answered on Sep 28, 2020 • 838 views
0helpful
1answer

I have a Beverage-Air MT27 and the door sags down on the side opposite the hinges and also leaves an air gap at the top on that side. I have tried adjusting to no luck. Any suggestions?

can you unbolt lower hinge from Door and put thin spacer between hinge and door. that should lift opposite side.
3/22/2016 3:24:18 PM • Beverage-Air... • Answered on Mar 22, 2016 • 491 views
0helpful
2answers

Why is my Beverage-Air refridgerator running all of the time?

Door seals torn, poor air circulation over condenser coils or evaporator coil, defective thermostat, not defrosting or low on Freon. APPLIANCE 911
6/25/2017 12:20:57 AM • Beverage-Air... • Answered on Jun 25, 2017 • 621 views
0helpful
1answer

Sparks coming from compressor, smells like burnt rubber

Sounds like the wiring has shorted that connects to the compressor. Shut the power off and remove the cover to the compressor terminals. You should see what you are looking for.
10/18/2014 6:21:07 AM • Beverage-Air... • Answered on Oct 18, 2014 • 184 views
0helpful
1answer

Fan runs constant

The fan is supposed to run constantly and they do get noisy. Take it out and go to grainger or a refrigeration supply house and they will match it up with a replacement. Its a very common part. Good luck and hope this helps.
10/18/2014 6:02:30 AM • Beverage-Air... • Answered on Oct 18, 2014 • 263 views
0helpful
1answer

How to add refrigerant to mt27

You should check the condenser to see that it is clean. Is the compressor running? If you have a leak, putting in gas wont help. You need to look for oil on the components around the compressor, inside the cooling coil housing. Hope this helps good luck.
8/11/2016 4:34:53 AM • Beverage-Air... • Answered on Aug 11, 2016 • 443 views
0helpful
1answer

Condenser Fan Shuts off after 15-20min, Compressor continues to run but gets hot

Condenser fan motor or motor wiring is bad. That compressor should never run without the fan. Good luck.
10/18/2014 5:45:07 AM • Beverage-Air... • Answered on Oct 18, 2014 • 417 views
0helpful
1answer

Cooler keeps freezing product

You killed the messenger! The refrigerant charge is probably the problem. The thermostat senses the coil temperature and not the cabinet temperature. If somebody put gas in it, the gas has to be removed, a vacuum drawn on the system and then the refrigerant charge weighed in by the ounce. It takes a critical charge and needs to be weighed in by an accurate scale that weighs in ounces. Hope this helps and good luck.
10/18/2014 5:39:41 AM • Beverage-Air... • Answered on Oct 18, 2014 • 250 views
0helpful
1answer

What could cause the cooler to freeze other than a faulty thermostat?

Improper refrigerant charge. Its critical and measures coil temp and not cabinet temp. If you did add gas that is the answer. Take out all the gas, put vacuum pump on it, then weigh in exactly in ounces the correct charge, its listed on the spec. tag. Hope this helps and good luck.
10/18/2014 5:34:04 AM • Beverage-Air... • Answered on Oct 18, 2014 • 158 views
0helpful
1answer

What could cause the cooler to fall below freezing temp other than a faulty thermostat?

Failed temp-sensor ?
7/17/2014 2:55:22 PM • Beverage-Air... • Answered on Jul 17, 2014 • 241 views
0helpful
1answer

What will make a beverage air mt27 not cool

Multiple reasons. Is it turned on & set. Is the fan inside & out turning fast. Is there frost on a line at the compressor Is the compressor outside cabinet s/b hot & vibrating continually. Is the condenser (attached to compressor with radiator) warm/hot & not plugged with lint etc between the fins. ?????
7/1/2014 3:46:22 PM • Beverage-Air... • Answered on Jul 01, 2014 • 787 views
0helpful
1answer

The doors stick and are

Hello, We specialize in cooler gaskets and refrigeration hardware. If you need to replace the hinges for your MT27 we can ID the exact ones needed for your units if you provide both model and serial #. We have great relationships with many of the OEM part suppliers and can offer parts below list price. Let us know if we can be of any help. Matt - 855-288-2259 [email protected]
1/2/2014 9:08:26 PM • Beverage-Air... • Answered on Jan 02, 2014 • 100 views
0helpful
1answer

Wiring

Yes they do with majority of models...
5/14/2013 3:07:24 PM • Beverage-Air... • Answered on May 14, 2013 • 403 views
0helpful
2answers

What does the overload relay look like a

Normally thermal overloads have a button like appearance on the compressor. Designed to open circuit when temp has caused distortion to the bi-metal contacts. Upon cooling will close again. Disconnect power before checking continunity on the overload terminals.
11/18/2011 1:05:31 PM • Beverage-Air... • Answered on Nov 18, 2011 • 667 views
Not finding what you are looking for?
Beverage-Air MT27 Beverage Cooler Commercial Logo

77 questions posted

Ask a Question

Usually answered in minutes!

Top Beverage-Air Refrigerators Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66835 Answers

Jorgie  the...
Jorgie the...

Level 3 Expert

5639 Answers

Are you a Beverage-Air Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...