Try this procedure.
The scan head locking
switch is locked. Unlock the scan head locking switch and turn the
power
switch
off/on.-------------- If this is not helping then try this procedure:---
The unit will not
function. Turn the power switch off and then switch it on, and if there is
again an
error, remove the power
cord from the outlet, and wait for 2 minutes then reconnect it and recheck.
--------------------------
Also as you mentioned
that Error E-7 is appearing o the display.But above error E-7 it shows number
like (E-7:01 OR E-7:10).So what number its showing above E-7 so as per that the
exact fault can be checked.
I will give you error
code list for all possible E-7 error codes.:---]
after you press START or print key
it'll show you two digits e.g. 10 (E7-10 altogether).Once it shows E-7 then
press the start or print key to get this two digit error code.:----
E7 03 Lens position error. E7 04 White level calibration error .E705 Black level calibration error E712 CCD calibration error. E7-11 is white level calibration error.E7 15 is for exposure lamp or inverter problem.------------This has to be checked.This will help.Thanks.Helpmech.