20 Most Recent
Pentair Minimax NT Heater Questions & Answers
Pentair MiniMax NT, won't stay lit.
Check the hose going from the fan housing to the control board. I found that it was very loose at the fan connection; wrapped a thin strip of masking tape around the barb, reconnected the hose and it works fine now.
Purex Triton MiniMax Plus 400
if you have incoming power, you may have a bad transformer. those systems run on 24-28v. you can check from yellow wire to yellow wire coming off the transformer to see if you have anything coming out. must check wires coming out of the transformer to each other, it won't register if you check each one individually to ground. hope this helps...
Pentair Minimax NT 400 heater. fan keeps coming
Sounds like the controller is the problem. This is the circuit board that has the display and controls on it. You can swing that panel open and try tapping on the white plastic cover the controller is under that. This might get the fan relay to release but you will have to replace the controller it will stick again
Minimax NT.. Shows green power
I would call the Pentair technical support line because they may be able to help you figure this thing out. I hope this helps.
Please vote on this answer. Thank You.