20 Most Recent Goodman CKL36AR36 Air Conditioner Questions & Answers


Factory parts warranty is five years all parts one year labor. Capacitor and/or fan motor has gone out and will need replaced. The breaker will throw itself off if the condition gets bad enough. Suggest not using until repaired, turn off breaker.

Goodman... | Answered on Oct 30, 2018


call in the technicians
compressor shutting down or power to the fan being interrupted causing the compressor to shut down

Goodman... | Answered on Jan 23, 2018


point of piston goes toward coil

Goodman... | Answered on Aug 18, 2015


there is a 3 amp automotive type fuse on circuit board to protect transformer in air handler

Goodman... | Answered on Aug 14, 2015


fan relay stuck in.

Goodman... | Answered on Aug 14, 2015


most dont have a high pressure safety. the compresor trips on internal drawing to many amps.

Goodman... | Answered on Aug 14, 2015


ihe 5 minute delay is to prevent damage to your compressor. some safety is shutting it down.

Goodman... | Answered on Aug 14, 2015


stopped up drain or rusted out pan. should have auxiallry pan under a/c air-handler.

Goodman... | Answered on Aug 12, 2015


drain pan stopped up or rusted through. if you are talking freon leak has to be repired by a pro.

Goodman... | Answered on Aug 11, 2015


either you have refrigerant leak or compressor bad.

Goodman... | Answered on Aug 11, 2015


on the side of compressor is a plastic snap on cover. behind cover are 3 terminals labeled r for run c for common and s for start. make sure a wire has not burned off. remember power has to be off and capacitors store a charge that can hurt you.

Goodman... | Answered on Aug 09, 2015


possible but i would check line set first.

Goodman... | Answered on Jul 05, 2015


The compressor has three terminals, Common, Start and Run.... The terminals read left to right, top to bottom just like pages in a book. So if theres one on top, its Common then Start will be the first one in the next row. If theres two on top, it'll be Common on the left and Start on the right then Run on the bottom.

The run capacitor wires in between Start and Run and line voltage is applied to Common and Run.

Goodman... | Answered on Apr 14, 2015


Wiring diagram is on the inside of the service panel on the condensing unit.

Goodman... | Answered on Apr 11, 2015


Freon can only be added to a refrigeration system by an EPA qualified technician

Goodman... | Answered on Mar 26, 2015


The wiring diagram is on the inside of the door on the blower/air handler unit.

Goodman... | Answered on Jan 08, 2015

Not finding what you are looking for?
Goodman CKL36AR36 Air Conditioner Logo

217 questions posted

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3417 Answers

Paul
Paul

Level 2 Expert

144 Answers

Tom Palicke

Level 1 Expert

45 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Goodman Heating & Cooling

  • Goodman Heating & Cooling

Most Popular Question

outside ac unit not blowing goodman dk

  • Heating & Cooling
Loading...