<?xml version="1.0" encoding="us-ascii"?><rss version="2.0"><channel><title>Goodman CLJ30AR32 Air Conditioner Support</title><link>http://www.fixya.com/support/p112926-goodman_clj30ar32_air_conditioner</link><description>Solved  technical support problems provided by FixYa users.</description><language>en-us</language><copyright>Copyright (c) 2007  FixYa, LTD.  All rights reserved.</copyright><webMaster>info@fixya.com</webMaster><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate><ttl>80</ttl><item><title>My heat pump package unit compressor draws high amps</title><link>http://www.fixya.com/support/t3691799-heat_pump_package_unit_compressor_draws</link><description>My heat pump package unit compressor draws high amps and keeps going up until it blows the 40 amp fuse on heat only. and on cooling only works for a minute or two and shuts off and starts again but draws only 18 amps well below the 25 RLA on the...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Code #33 on Bryant 355MAV 90i Furnace</title><link>http://www.fixya.com/support/t1727495-code_33_bryant_355mav_90i_furnace</link><description>Have been getting a code #33 on my Bryant 355MAV 100k btu furnace, Evolution controls (installed new 2006) every heating season for three years since we built the house. Installers solution was to turn down gas pressures (lp) which, while allowing...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Half of the house is blowing cold air the other</title><link>http://www.fixya.com/support/t2674330-half_house_blowing_cold_air_other</link><description>Half of the house is blowing cold air the other half is blowing just air</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>my heater never stops working</title><link>http://www.fixya.com/support/t3615989-heater_never_stops_working</link><description>my heater never stops working even if i turn it off</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>How do I get to the overflow tray to drain it?</title><link>http://www.fixya.com/support/t3502565-get_overflow_tray_drain</link><description>How do I get to the overflow tray to drain it? Where is it located?</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>what makes heat change over to aux heat?</title><link>http://www.fixya.com/support/t3217087-makes_heat_change_over_aux_heat</link><description>what makes heat change over to aux heat?</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>how do you drain the overflow tray?</title><link>http://www.fixya.com/support/t3037164-drain_overflow_tray</link><description>how do you drain the overflow tray?</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>contact is stick together</title><link>http://www.fixya.com/support/t2916819-contact_stick_together</link><description>contact is stick together</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>AC unit outside blowing out cold air, vents</title><link>http://www.fixya.com/support/t2855746-ac_unit_outside_blowing_out_cold_air</link><description>AC unit outside blowing out cold air...a lot of cold air. House is warm, vents shooting out warm air</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>fan on outside a/c unit blows cool air, not hot as usual</title><link>http://www.fixya.com/support/t2798631-fan_outside_c_unit_blows_cool_air_not</link><description>Dual run capacitor was changed as herm connect was fried. New connection did not produce cool air. Need to verify if compressor is bad, r-22 level is ok. Is it best to change entire condensing unit 0n 13 year old Goodman model #CK36-18 which is...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>I have an older Goodman CKB 18-1</title><link>http://www.fixya.com/support/t2688607-older_goodman_ckb_18_1</link><description>The AC stopped working today. the indoor blower works the thermostat seems to be fine. I walked outside and listened. The fan blades do not turn, i felt the top of the unit and the metal was hot. The blades turn free. I heard the sound of the...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Filter for Bryant plus 90i</title><link>http://www.fixya.com/support/t2514441-filter_bryant_plus_90i</link><description>I am trying to find a filter for my Bryant plus 90i furnace. It seems to take an odd-sized filter but I cannot find accurate dimensions from any of the manuals, specs, online or offline sites. The Bryant dealership itself couldn't even give me a...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>charging ac system</title><link>http://www.fixya.com/support/t2453643-charging_ac_system</link><description>what is the correct way to charge a goodman ac system</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>my goodman heat pump will not go to aux heat from</title><link>http://www.fixya.com/support/t2431713-goodman_heat_pump_will_not_go_aux_heat</link><description>my goodman heat pump will not go to aux heat from the thermostate manual, did i wire the thermostate wrong</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>continues running of air and heat when switch</title><link>http://www.fixya.com/support/t2415931-continues_running_air_heat_when_switch</link><description>continues running of air and heat when switch</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Thermostat is not working properly. Readings are</title><link>http://www.fixya.com/support/t2349412-thermostat_not_working_properly</link><description>Thermostat is not working properly. Readings are not accurate, and I've replaced the batteries several times for a few weeks now only to find they are leaking...watery, grayish substance all around the batteries. Batteries are brand new Duracell AA...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>AC working but no air coming in the house</title><link>http://www.fixya.com/support/t2291692-ac_working_but_no_air_coming_in_house</link><description>AC running but no air coming 
\into the house</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Came home today and the AC will not come back on.  The out side unit is working, but the blower inside will not come on.  Also the light on the control board will not light up at all.  Does anyone hav</title><link>http://www.fixya.com/support/t2313315-came_home_today_ac_will_not_come_back</link><description>Got home today and the air will not come back on.  The out side unit is working but the indoor blower will not come on.  Also the light on the control board is not and will not light up.  Can someone help?</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>A/C comes on but fan inside does not --- Help!</title><link>http://www.fixya.com/support/t2279030-c_comes_but_fan_inside_not_help</link><description>Problem- A/C comes on but fan inside does not. You can feel the cold air coming out from the bottom of the a/c but fan is not comming on at the same time to. It's selective and doesn't happen all the time....sometimes the fan kicks on like its...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Goodman CLJ30AR32 Air Conditioner fan wont operate</title><link>http://www.fixya.com/support/t695411-goodman_clj30ar32_air_conditioner_fan</link><description>fan wont operate</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>OUT SIDE FAN DOES NOT START WHEN A/C UNIT COMES</title><link>http://www.fixya.com/support/t2132040-out_side_fan_not_start_when_c_unit_comes</link><description>OUT SIDE FAN DOES NOT START WHEN A/C UNIT COMES ON. tHE FAN WILL START IF YOU GIVE THE BLADE A SPIN MANUALLY.</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>unit freezes up when nearing 8-12 degree superheat</title><link>http://www.fixya.com/support/t2109204-unit_freezes_up_when_nearing_8_12_degree</link><description>1/4 of evaporator is stopped up...large line freezes up when adding freon also</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Goodman AC unit - fan starting outside but not getting cool air.</title><link>http://www.fixya.com/support/t2099255-goodman_ac_unit_fan_starting_outside_but</link><description>I am sure this has been asked before .. but would appreciate if some one replies to it. I am quite novice when it comes to dealing with electrical issues. I have a two year old goodman unit. I tried starting it after winter. I can see the fan is...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>In thermostat when turn on to cool fuse goes blown</title><link>http://www.fixya.com/support/t1916706-in_thermostat_when_turn_cool_fuse_goes</link><description>In thermostat when turn on to cool fuse goes blown</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>What causes the pulse control on the ac circuit board to fail?</title><link>http://www.fixya.com/support/t1758491-causes_pulse_control_ac_circuit_board</link><description>The power indicator on the air-conditioner lights up when switched on, but when the pulse is applied on the ac control board the ac fails to start.</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>freon leaking</title><link>http://www.fixya.com/support/t699266-freon_leaking</link><description>my unit is only 4 yrs old. in the winter it was not working, he put 2# of freon, said that the sequensers needed replaced. Then they came back when summer hit and put in 7# of freon, did not check for leak, and now are saying that they have to come...</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>air conditioning unit</title><link>http://www.fixya.com/support/t768717-air_conditioning_unit</link><description>copper pipes are iceing over. I shut it off and they melted. so I turned it back on and it was working but now the pipes are iced over again.</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>the fan hums wont turn goodman air conditioning</title><link>http://www.fixya.com/support/t1828505-fan_hums_wont_turn_goodman_air</link><description>hums fan wont turn,wont do any thing but hum</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>Goodman GMP125-5 limit switch open</title><link>http://www.fixya.com/support/t1732361-goodman_gmp125_5_limit_switch_open</link><description>I have a Goodman Furnace GMP125-5. The circuit board indicated an open limit switch (4 blinks), either main or aux. How does one check the limit switches and where are they found? How does one fix the problem?</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item><item><title>tstat wiring</title><link>http://www.fixya.com/support/t1580034-tstat_wiring</link><description>touched together and cant find fuse</description><pubDate>Mon, 28 Dec 2009 03:15:12 GMT</pubDate></item></channel></rss>