<?xml version="1.0" encoding="us-ascii"?><rss version="2.0"><channel><title>Rheem RTG-74PVN-2 Natural Gas Pronto Whole House, Natural Gas, Tankless Wat Support</title><link>http://www.fixya.com/support/p1018682-rheem_rtg_74pvn_2_natural_gas_pronto_who</link><description>Solved  technical support problems provided by FixYa users.</description><language>en-us</language><copyright>Copyright (c) 2007  FixYa, LTD.  All rights reserved.</copyright><webMaster>info@fixya.com</webMaster><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate><ttl>80</ttl><item><title>Hi, I have a Rheem RTG-74PVN-2 tankless hot water</title><link>http://www.fixya.com/support/t3511399-rheem_rtg_74pvn_2_tankless_hot_water</link><description>Hi, I have a Rheem RTG-74PVN-2 tankless hot water heater. It has run great for about a year, but now shuts off completely after running for approx. 8-10 minutes. I have the water temp set at 130 f. Any suggestions?</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>FLASHING CODE C-7 WILL WORK FOR A WHILE THEN STOPS</title><link>http://www.fixya.com/support/t3437747-flashing_code_c_7_will_work_while_stops</link><description>FLASHING CODE C-7 WILL WORK FOR A WHILE THEN STOPS</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>c2 11 code, same problem as others. Used to be</title><link>http://www.fixya.com/support/t3452570-c2_11_code_same_problem_as_others_used</link><description>c2 11 code, same problem as others. Used to be hvac tech. Gas fine, vent fine,grounded properly, tore unit apart and inspected and cleaned entire thing. Looking for new ideas, what has worked for others.</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>My Rheem Pronto model#RTG-74PNV-1 has powered off</title><link>http://www.fixya.com/support/t3073279-rheem_pronto_model_rtg_74pnv_1_powered</link><description>My Rheem Pronto model#RTG-74PNV-1 has powered off for some reason unknown, I turned the unit back on and it supplied hot water for approx. 10 minutes before it started flashing a code [C7]on the remote control UMC-117. Any idea what this code means....</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>code c876</title><link>http://www.fixya.com/support/t3329980-code_c876</link><description>code c876</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Rheem Tankless wh model rtg-74pvn shuts off error code c4 76</title><link>http://www.fixya.com/support/t3330148-rheem_tankless_wh_model_rtg_74pvn_shuts</link><description>Rheem Tankless waterheater modek rtg-74pvn installed 2 yrs ago, unit shuts off wo warning, error codes displayed c7 76. I turn of unit and restart and it runs ok for a while then shuts off for no real reason. Only other appliance running would be the...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>code C876 I un pluged the unit waited two minuits</title><link>http://www.fixya.com/support/t3330090-code_c876_un_pluged_unit_waited_two</link><description>code C876 I un pluged the unit waited two minuits and pluged in again worked one time an coaded again.Unit aprox. 2 years old now and the recall work was performed when the same code(C876)came up the first time at aprox. 1year old</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>C4 13 error flashing on water heater, shuts off after a minute</title><link>http://www.fixya.com/support/t3119849-c4_13_error_flashing_water_heater_shuts</link><description>Our water heater was shutting off after about a minute of use.  I called the Rheem support number and they told me:    1.  They wouldn't support me because I used flexible pipe for the gas line -- it had to be black pipe.  The fact that the manual...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Rheem tankless water heater error A3 than flashes</title><link>http://www.fixya.com/support/t1879821-rheem_tankless_water_heater_error_a3</link><description>Rheem tankless water heater error A3 than flashes 61 - there is no hot water at all</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>same problem same time frame</title><link>http://www.fixya.com/support/t2877072-same_problem_same_time_frame</link><description>4 hrs of my trouble shooting, a new circuit board, and 3 hrs of tech trouble shooting. and its only gotten worse.</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>My Rheem Pronto water heater comes on then shuts</title><link>http://www.fixya.com/support/t3059632-rheem_pronto_water_heater_comes_shuts</link><description>My Rheem Pronto water heater comes on then shuts off within 30 seconds and flashes a code 7</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>53PVN shuts off after a few minutes</title><link>http://www.fixya.com/support/t2907525-53pvn_shuts_off_after_few_minutes</link><description>My new 53PVN shuts down after a few minutes, with the error code C4 13. It is very well ventilated, nothing in front or on the sides. I am at 7000 feet but without a high-altitude chip. Could this possibly be the problem?</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>error 82 appearing after replacing motherboard</title><link>http://www.fixya.com/support/t2683138-error_82_appearing_after_replacing</link><description>Was receiving an error code of c4 76.  Called Paloma and they shipped a new motherboard to me after saying the controller and motherboard weren't communicating.  Have installed new motherboard per provided instructions and am getting an error code of...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Heater shuts down with C4-13 code</title><link>http://www.fixya.com/support/t2699032-heater_shuts_down_c4_13_code</link><description>Rheem tankless shuts down after a couple of minutes. Error code c4 - 13 (alternating). Then I have to reset th unit: turn off &amp;amp; on via the remote and the error code goes away until the next time we use the unity. I called Rheem but they couldn't...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Hi there, do you know what error code 82 C2 means</title><link>http://www.fixya.com/support/t2536195-know_error_code_82_c2_means</link><description>Hi there, do you know what error code 82 C2 means and how I can reset the unit?</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Rheem Pronto Hotwater Heater Error</title><link>http://www.fixya.com/support/t2400093-rheem_pronto_hotwater_heater_error</link><description>I received a similar error C7-76. I called Rheem and they're sending me out a new board and chip that according to them can be self installed. Once put in place I have to call them to program the chip. Until then I was told I have no hot water. :(...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>have a rheem central air conditioner heater.  I</title><link>http://www.fixya.com/support/t2099300-rheem_central_air_conditioner_heater</link><description>have a rheem central air conditioner heater. I turn the termostate above room temp. It turns on and you can see a bright glowing in the unit but the burners never ignite. It is a self igniting unit and only about 5 to 6 years old. Any idea why it...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>C2-11 error, burners shut off and water goes cold</title><link>http://www.fixya.com/support/t1954519-c2_11_error_burners_shut_off_water_goes</link><description>This unit was new and it has operated just fine for 18 months and suddenly it has begun to intermittently shut down and display a "C2 11" error code while leaving me with nothing but cold water in the shower.  My manual indicates eight possible...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>how to correct error code C-7 on my RTG-74PVN Rheem Pronto</title><link>http://www.fixya.com/support/t1526106-correct_error_code_c_7_rtg_74pvn_rheem</link><description>Hot water heater kicks off when using hot water. Monitor shows C-7 code. I cleaned both water filter and air intake filters. What else can I do to fix this problem?</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Rheem tanless waterheater cuts of with error code c4 then 13.</title><link>http://www.fixya.com/support/t1698058-rheem_tanless_waterheater_cuts_error</link><description>Enviro plumbing, Irving tx. thought the problem to be the absence of the condensation tee; installed and did not solve problem.</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>Hooking up Tandem Rinnai R94 LSi</title><link>http://www.fixya.com/support/t987987-hooking_up_tandem_rinnai_r94_lsi</link><description>Hi we need to connect our two Rinnai R94 LSi in tandem. DO you have a diagram on how it should be done? On a prior post I noticed you stated we would need a master controller or panel. Where do we find these? Thanks. Daniel Brown...</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>how do i servis a glowworm compact boiler</title><link>http://www.fixya.com/support/t1014359-servis_glowworm_compact_boiler</link><description>can you help me please</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>instructions for my Ideal Mexico CF60P Propane boiler</title><link>http://www.fixya.com/support/t1017615-instructions_ideal_mexico_cf60p_propane</link><description>Help! Where can I download instructions/user manual/installation guide for the above boiler please? It isn't heating my hot water very much an I wanna figure out why if possible. Cheers very much. Marie x</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>How to re pressurisecentral heating system</title><link>http://www.fixya.com/support/t1080931-re_pressurisecentral_heating_system</link><description>The Alpha SY24 boiler has stopped working. The pressure gauge has dropped, we need to know how to re pressurise the system once the radiators have been bled</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>starting a pilot light on a hot water heater</title><link>http://www.fixya.com/support/t1130203-starting_pilot_light_hot_water_heater</link><description>water heaters I ran out of oil,so got more oil in tank.blead the lines.but now i cant get pilot to start</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item><item><title>plumbing</title><link>http://www.fixya.com/support/t1170219-plumbing</link><description>how do you drain down combi central heating system. i want to replace old bathroom radiator with towel radiator.</description><pubDate>Wed, 23 Dec 2009 12:59:02 GMT</pubDate></item></channel></rss>