Water wizard 10P pilot light keeps going out

If the thermocoupler is defective the gas to everything is shut off. The coupler is the bulb that sits ib the pilot flame If it doesn't heat up it will sense no pilot and shut the gas off. They don't cost much and are easy to change. Good Luck, Ned
10/22/2022 11:58:58 AM • Bosch & Tankless... • Answered on Oct 22, 2022 • 2,828 views
0helpful
1answer

My Bosh (240fx) runs hot and cold constantly

It sounds like a bad flo switch. If not, then the problem is more likely in the mother board. Call Bosch back and ask for a supervisor right away. The peons sometimes are given advancement according to how many calls they handle, so they have a time crunch. Go right to the supervisor. Good luck!
2/5/2018 5:39:02 PM • Bosch & Tankless... • Answered on Feb 05, 2018 • 107 views
0helpful
1answer

Bosch tankless hot water heater: Confort TOO HOT!!!

Look for a water temp control on unit. Otherwise a lower temp can be attained by having a higher water flow to minimize temperature buildup in heating coil.
9/6/2017 7:55:36 PM • Bosch & Tankless... • Answered on Sep 06, 2017 • 304 views
0helpful
1answer

Temperature with my on demand water heater is inconsistent

have a plumber check the installation as it appears that there is a temp control mixer in the kitchen line that should be in the bathroom line Many states and countries now have made it mandatory the full uncontrolled hot water cannot be used in a bath, shower, wash basin but has to limited to a max temp of 70 C to prevent burns to the skin
5/29/2017 11:49:34 PM • Bosch & Tankless... • Answered on May 29, 2017 • 194 views
0helpful
1answer

I have a bosch aquastar aq 125fx probably 9 to 10

You either have a weak spark from your ignitor which needs replacing, a bad elec connection to the ignitor, or it needs to be repositioned nearer the burner. Check connections and try repositioning it before you install a new on.
5/8/2017 5:59:55 PM • Bosch & Tankless... • Answered on May 08, 2017 • 265 views
0helpful
2answers

I have a PowerStar model

Open following link for Bosch tankless troubleshooting resources, including Bosch contact information, typical manuals, error codes, tech support, parts, fuel-saver calculator, service bulletins, water heater forum, fixya links, disclaimers, and links for finding service technician.
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html

Read manual cover to cover, make sure tankless receives yearly maintenance as outline in manual.

Add a comment with your experience so others with same-similar problem can benefit.

Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
11/1/2016 2:47:35 PM • Bosch & Tankless... • Answered on Nov 01, 2016 • 602 views
0helpful
1answer

Bosch Confort S 13 BP tankless water heater won't ignite, It clicks but no gas going thru valve

The S 13 BP is a simple unit that does not have a pilot light. It uses electronic ignition on demand, which is what you hear clicking. If there is no gas going through and you've verified there is gas to the inlet, then it has to be the gas control valve.
2/11/2016 6:13:28 PM • Bosch & Tankless... • Answered on Feb 11, 2016 • 921 views
0helpful
1answer

Find manual for 425 ng tankless

http://www.ps2netdrivers.net/parts/bosch.gwh.425.hn/
11/11/2014 5:50:52 AM • Bosch & Tankless... • Answered on Nov 11, 2014 • 216 views
0helpful
1answer

How do i gas heater gwh 2400 ctd efs Lp

Stupid me but could you be a little bit literate in asking a question.My dog write better questions that I can understand than this scribbling.A GWH 2400 is the little brother of the GWH 2700 much like the 635ES. If you have an LP model be sure to use the overpressure protection valve supplied by Bosch as overpressure in LP (above 10-14" WC) can completely destroy this unit.And you can use a TPR or PRV for 170,000+BTU being sure you get a House Pressure valve of 60-80-100 PSI+ and not the boiler PRV for 30 PSIBeyond that your questions above states nothing recognizable as a technical question
10/21/2014 7:31:54 PM • Bosch & Tankless... • Answered on Oct 21, 2014 • 235 views
0helpful
1answer

Water heater dia.is 19" what is the curcum. of the water heater. heigh is 4feet.nothing more to add

first time heard of a tankless that is round
9/16/2014 11:05:26 PM • Bosch & Tankless... • Answered on Sep 16, 2014 • 88 views
0helpful
1answer

Is there a operating manual for the bosch water wizard 10b

9/2/2014 10:19:14 PM • Bosch & Tankless... • Answered on Sep 02, 2014 • 384 views
0helpful
1answer

Pilot light located

It's in the Bochum owners manual page 7
8/11/2014 6:21:59 PM • Bosch & Tankless... • Answered on Aug 11, 2014 • 97 views
0helpful
2answers

Why is my Bosch high flow 21e heater started working intermittently only heating water after tap is turned on and off a few times

Check gas pressures first especially on low setting. Ensure gas burner is clean get unit serviced if over 2 years old. Check or replace water flow sensor & clean inlet filter.
2/5/2015 11:34:33 PM • Bosch & Tankless... • Answered on Feb 05, 2015 • 500 views
0helpful
2answers

Bosch 16h hydro

Check or replace diaphragm in the water section also clean the filter fitted at the inlet
8/6/2014 12:18:45 PM • Bosch & Tankless... • Answered on Aug 06, 2014 • 647 views
0helpful
2answers

Water heater burner won't shut off backflows water though cold supply and melts cold line

Define melts cold line.
7/26/2014 5:26:24 PM • Bosch & Tankless... • Answered on Jul 26, 2014 • 100 views
0helpful
4answers

Why does the spark igniter keep sparking after the burner is lit. I adjusted the microswitch because it was not lighting but now it will light but keep sparking every 5 sec, even though the burner is

the igniter probably did this prior to the adjustment if not check manuel if this not a safety back up to prevent gas from not being burned .
7/26/2014 3:54:15 PM • Bosch & Tankless... • Answered on Jul 26, 2014 • 1,023 views
0helpful
1answer

Why won't lp 125 shut off after you turn off faucet continues to burn then backflows hot water through cold supply line and melts it then pressures up and blows line

It sounds like there is too much pressure in the hot water pipes. You can try adjusting the pressure. Do it a little at a time to see how much hot water is coming out. The only other thing I can think of is that there is a large delay between the switch and the water flow. meaning you will need to stop the water a while before you actually want the water to stop flowing. Elisa Jed ' http://www.mccreeryhvac.com
7/16/2014 3:51:07 AM • Bosch & Tankless... • Answered on Jul 16, 2014 • 114 views
0helpful
1answer

Why do I have to keep resetting my nordyne water heater model 140dhmse4

need to know what you are resetting
7/12/2014 3:01:03 PM • Bosch & Tankless... • Answered on Jul 12, 2014 • 104 views
0helpful
2answers

My water heater keeps tripping the reset button on one of the two heaters. Anyone know what the problem might be

Reset Button.....be nice if you gave us a brand/model to go with. If you mean the small GFCI inside the heater, you'll need to get a Tech Service Call and call Mfrs Tech Support as something is short to ground. This can't be done remotely as you have to track currents and voltages and resistances with a multimeter. Tankless usually draw less than 2A even when fully on so doubtful you're overloading a general house circuit. Might even be the small interior GFCI that's bad. That's why you need Tech Support.
7/12/2014 1:44:40 AM • Bosch & Tankless... • Answered on Jul 12, 2014 • 472 views
0helpful
3answers

Bosch 13Hwater heater problems

Question is how am I to know what model this is? And as stated the question answers itself.....Plumber removed...did he reinstall? of course but as stated the issue is unanswerable. Does the Pilot light? or if this is an electronic unit than something in the feedback ignition sensor is amuck. Is this a 125VP, 125B, 125H. 38B or a 240FX, 250SX or 2400/2700 or newer?
6/17/2014 11:53:56 PM • Bosch & Tankless... • Answered on Jun 17, 2014 • 143 views
Not finding what you are looking for?
Bosch & Tankless LP Hot Water Heater  Logo

295 questions posted

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...