<?xml version="1.0" encoding="us-ascii"?><rss version="2.0"><channel><title> UPS Systems Devices Technical Support</title><link>http://www.fixya.com/support/browse/ups_systems_devices</link><description>Solved  technical support problems provided by FixYa users.</description><language>en-us</language><copyright>Copyright (c) 2007  FixYa, LTD.  All rights reserved.</copyright><webMaster>info@fixya.com</webMaster><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate><ttl>80</ttl><item><title>My APC bx900r is making a squealing noise with the</title><link>http://www.fixya.com/support/t3520904-apc_bx900r_making_squealing_noise</link><description>My APC bx900r is making a squealing noise with the red light flashing after a few minutes after being turned on. The brochure says this means it is overloaded, but nothing is plugged in to it. the Batteries both measure 12 volts. Are they dead</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>alarm sounds. I have had this unit more than 3</title><link>http://www.fixya.com/support/t3280545-alarm_sounds_unit_more_3</link><description>alarm sounds. I have had this unit more than 3 years so it cold be the battery I reset it and seems that it stop for the meantime. If sounds again is going to be the battery right?</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Dc bus faulty</title><link>http://www.fixya.com/support/t3252254-dc_bus_faulty</link><description>Dc bus faulty</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Have brand new APC 900 UPS and when plugged in,</title><link>http://www.fixya.com/support/t2976457-brand_new_apc_900_ups_when_plugged_in</link><description>Have brand new APC 900 UPS and when plugged in, both green &amp;amp; yellow indicator lights flash. Non-stop. Left unit plugged in for 18 hours (off) to charge battery as info sheet suggested, but lights still flash. Hesitant to plug it in line with new...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Problem with APC Pro 420</title><link>http://www.fixya.com/support/t2963603-problem_apc_pro_420</link><description>Hello I have a problem with my UPS. It is an APC Pro 420. I have conected 2 computers and 2 monitors to the UPS and in a blackout the UPS couldn't keep the machines turned on. Now the UPS can't keep 1 computer power on, it turns off when the UPS has...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Overload LED lit, constant warning tone, no load</title><link>http://www.fixya.com/support/t2926953-overload_led_lit_constant_warning_tone</link><description>Overload LED lit, constant warning tone, no load on unit. Is there an internal component available to repair this unit?</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>APC back-ups XS 800 battery backup : warning</title><link>http://www.fixya.com/support/t2779720-apc_back_ups_xs_800_battery_backup</link><description>"Battery not connected to unit"</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>I have a APC BX900R.  i HAVE REPLACED THE</title><link>http://www.fixya.com/support/t2761898-apc_bx900r_replaced</link><description>I have a APC BX900R. i HAVE REPLACED THE bATTERIES AND i STILL GET AN OVERLOAD ALARM WITH NO LOAD ON THE UNIT. wHAT IS WRONG?</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>I hear some tick sounds in ups and the ups doesnt</title><link>http://www.fixya.com/support/t2727179-hear_some_tick_sounds_in_ups_ups_doesnt</link><description>I hear some tick sounds in ups and the ups doesnt supports when there is a shutdown in power</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>The Battery symbol w/ the X thru it had the red</title><link>http://www.fixya.com/support/t2692808-battery_symbol_w_x_thru_red</link><description>The Battery symbol w/ the X thru it had the red light on. I replaced the batteries and the light is still on. Do I need to do something to make the light go off?</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>My Liebert PSA itON 600 UPS keeps beeping when i turned it on</title><link>http://www.fixya.com/support/t2667064-liebert_psa_iton_600_ups_keeps_beeping</link><description>I have a  Liebert PSA itON 600 UPS and when i switched it on it keeps beeping even if not connected to a power supply. Please help...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>I recently purchased a used Belkin F6C800-UNV UPS,</title><link>http://www.fixya.com/support/t2568377-recently_purchased_used_belkin_f6c800</link><description>I recently purchased a used Belkin F6C800-UNV UPS, and discovered it had bad batteries. I replaced both batteries, and charged the replacement batteries overnight. The UPS appears to be working correctly, except that the UPS output voltage, measured...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>I lost my i-mate jam driver CD and i can't find</title><link>http://www.fixya.com/support/t2530848-lost_mate_jam_driver_cd_find</link><description>I lost my i-mate jam driver CD and i can't find some free download anywhere what can i do? I need it for my laptop  somebody help me???</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>CP685AVR/BF685 Power Contro.</title><link>http://www.fixya.com/support/t2475450-cp685avr_bf685_power_contro</link><description>Hi, My unit is 4.5 years old. Worked Okay until yesterday. Electric power connected, and USB cable reconnected, unit is dead. Red circuit breaker button is pushed in: Never was activated or pushed out. Press the "ON" button,the light sometimes...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>my ups will not stop beeping - I tried to unplug</title><link>http://www.fixya.com/support/t2447923-ups_will_not_stop_beeping_tried_unplug</link><description>my ups will not stop beeping - I tried to unplug it etc. help</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>APC back-ups es500 alarm continuously sounds why</title><link>http://www.fixya.com/support/t2434218-apc_back_ups_es500_alarm_continuously</link><description>APC back-ups es500 alarm continuously sounds why we power it off and alarm stops everything works fine then we power it back on and alarms sounds again</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>phone line goes dead</title><link>http://www.fixya.com/support/t2342568-phone_line_goes_dead</link><description>i purchased a ikasu dm076831 router but when i set it up i cant get my phone line to work,please any help will be appreciated.rgrds paul.</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>panamax max 1500 doesn't work</title><link>http://www.fixya.com/support/t2324417-panamax_max_1500_doesnt_work</link><description>Has a red overvoltage light on the front panel but I can't find a reset button and of course the owners manual is nowhere to be found</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Dynex Te685avr backup battery doesnt work</title><link>http://www.fixya.com/support/t2310878-dynex_te685avr_backup_battery_doesnt</link><description>I have owned a Dynex surge protector (model Te685avr) for almost 6 years now. Two days ago I was out of the house and we lost power for an hour. When I came back my computer had shut down. What I assumed happened is that while I was gone my backup...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>UPS not charging</title><link>http://www.fixya.com/support/t2282668-ups_not_charging</link><description>Sir, Our UPS is not charging at all. After following the procedure for shuting and starting up, it show battery charging 0%. The model is MGE Galaxy 3000 UPS Thanks My UPS was left uncharged for days. Now when i tried to charge it,it is not working....</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Suddenly everything lost power and the CPS1100AVR UPS unit started beeping and clicking while switching back-and-forth from 'powered' to 'battery'. Everything connected powered off, then on, then off,</title><link>http://www.fixya.com/support/t2269245-suddenly_everything_lost_power</link><description>This morning, while doing nothing special on the PC, suddenly it powered down and I could hear the UPS intermittently beeping and clicking. Anything not plugged into the UPS remained powered up, meaning there was no power outage. Also connected to...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Car Stereo Battery replacement</title><link>http://www.fixya.com/support/t2259969-car_stereo_battery_replacement</link><description>hey, ive been trying to save money to replace my kinetik battery hooked up to my subs. its going a little slower than planned and i would like to get my stereo back up and bumpin. Heres my question: i have a bank of eight Panasonic LC-R127R2P1 12v,...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Belkin 1100VA Power Back up has started beeping</title><link>http://www.fixya.com/support/t2242845-belkin_1100va_power_back_up_started</link><description>Belkin 1100VA Power Back up has started beeping (single beep) approx every 5 or 10 seconds. Lost my manual so don't know what this represents. Any help appreciated</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>I need to study the circuit diagrams of UPS to</title><link>http://www.fixya.com/support/t2184749-need_study_circuit_diagrams_ups</link><description>I need to study the circuit diagrams of UPS to understand how it works, thanks</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>smple script for graceful shutdown of Windows OS</title><link>http://www.fixya.com/support/t2168848-smple_script_graceful_shutdown_windows</link><description>Could anyone help me to make make a smple script that launches graceful shutdown of Windows OS. Can the same script cancel shutdown in case of immediate power restore? Thank you for your help.</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>Unit will not turn ON.</title><link>http://www.fixya.com/support/t2136698-unit_will_not_turn</link><description>Have removed cover and verified that power is flowing in through the circuit breaker.  Will need schematic to do circuit tracing.  Hopefully someone will have one and be able to share. Thanks.</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>UPS shuts down when the mains is off.</title><link>http://www.fixya.com/support/t2087089-ups_shuts_down_when_mains_off</link><description>My Powercom UPS shuts down itself when the mains is off. But its back up was fine. Last night when the power went off, my ups shut down itself and thus my pc went off. Now the UPS is not at all working when mains is off. When i try to switch it on,...</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>my emerge UPS 500 is not at all giving backup..</title><link>http://www.fixya.com/support/t2048182-emerge_ups_500_not_all_giving_backup</link><description>my emerge UPS 500 is not at all giving backup.. its stays only for 1min after power goes.. before it had given more than 10 min but now it not even stands for 1 min.. pls help me.. wat i have to do??</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>mge galaxy 20kva ups input breaker trip</title><link>http://www.fixya.com/support/t1940105-mge_galaxy_20kva_ups_input_breaker_trip</link><description>what is the cause of my ups breaker triping</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item><item><title>UPS Beep doesn't stop after turning it on. - Powercom kin-100a</title><link>http://www.fixya.com/support/t1904988-ups_beep_doesnt_stop_after_turning</link><description>Beep doesn't stop after turning it on. It's been 2 hours and it doesn't stop yet.It's a continous beep. The computer to which it's connected is on and working ok.</description><pubDate>Mon, 21 Dec 2009 08:47:09 GMT</pubDate></item></channel></rss>