...it is giving me a message that says "fault check ignition control." Any ideas? check the high limit safeties, and thermal fuse for the high heat fault........ignition control can be a separate ...
fl 4 code fl4 = Igniter Failure A. Igniter circuit is open: Check fuses on igniter wires B. Element has a fine crack in it: Replace igniter C. Igniter fault: Replace igniter
Newly installed igniter won't work Replaced with igniter from Direct Ignite. Looks just like original. power going to hot wire, but nothing happening with igniter. Is it correctly earthed to the frame
pool heater will not come on and displays a number 4 and service heater After reading the manual at http://www.jandy-downloads.com/pdfs/H0248900D.pdf, I found the FL4 fault indicates an igniter ...
...ignition control board. Find them and confirm with an ohm meter and replace them. Be sure to check the ignitor leads for a ground fault prior to restarting the heater since a ground could have caused ...
...fault 2 no ignition-sometimes temp stays-igniter shows up-clicks but burners do not go on. burners are plug with spider get a wire and bended get it inside the orifices where the gas come out every ...
fl4 and fl3 fault fl4 and fl3 faul how do I fix this? fl3 not rectification fl4 fault ignitions must replace ignitor kit and rectification kit from jandy need model # for parts
jandy lite 2 heater model lj325n - code fl4 - hot surface igniter problem- I tapped the gas valve and checked the fuse , still getting the same code. Igniter circuit is open. Check fuses on igniter ...