...pool heater Raypak gas pool heater ignites normally but 20-30 seconds after ignition flame flares up on right hand side You will need to pull the burner tray out and clean and blow out the burners. ...
...POOL HEATER IGNITES AND HEATS UP, BUT 30 SECONDS LATER STARTS BANGING AND SHAKES sounds like you have a bad thermal governor (regulates water temp inside the heat exchanger) or your pH has been to ...
...Heater heats spa to approx 20 degrees then starts to cycle, Shuts burners and ignition off, Then goes thru startup procedure and re-ignites and heats for approx 30 secs then shuts off. It will ...
...stay lit i have an h200 NG heater the heater lites then shuts off in about 30 sec flame sensor is probably dirty.remove and clean with fine steel wool.it is located near bottom of burner near ...
...pool heater on our pool with a 1.5 hp pool pump. I get no LED problem read out, but the gas won't ignite. The blower comes on for about 30 seconds, then goes off completely, at which time the screen ...
...heater ignites easily, stays lit for 30 seconds, then turns off, then kicks back up in 30 seconds. Burners look great? Not sure what could be wrong? If you have a pilot their will be a flame sensor ...
pool heater Please refer to page 30 of this owners manual under the section labeled Ignitor assembley removal. This should help to guide you through the removal and installation process. Refer to page