Question about Hayward Pool & Spa
...pilot generator replaced and also replaced gas valve. Pilot flame is strong ,gas pressure good. Am i wrong in thinking that the control circuit is not a part of the pilot staying lit. Was thinking a ...
pilot generator" that sits in the flame of the pilot light. This generates a low voltage output from the flame of the pilot light. This voltage goes to the gas valve and tells the valve that the pilot
...pilot generator or the pilot head itself is the issue. You need a good, solid blue flame across the generator to get enough power to hold the switch open when you let go of the knob. If the pilot ...
Question about Pool & Spa
...pilot generator on a Jandy Lite 2 pool heater? The pilot will stay lit but the main burners will not come on. Jumpering the gas valve will ignite the main burners and the Do I need to disconnect the ...
...replaced pilot generator pilot that whole unit nice pilot but wont fire problem isnt with the pilot generator. you have either an open safety withing circuit, lose wiring connection, or tstat ...
pilot generator from a minimax ch 200m shut off gas supply. undo gas line union. remove wiring from gas valve. undo burner tray support screws. slide burner tray out. remove pilot generator leads from
...pilot generator yet? A millivolt heater (one with a pilot light) requires about .75 volts from the generator to operate. As the generator ages it puts out less and less voltage and eventually gets to ...
...Pilot generator twice. In live in USVI. Was told salt air ruines the generators. I live in middle of Island (not next to the sea). Pilot stays lit. Furnice will not fire. Is there a conversion to ...