...stands for "ignition failure". This can be caused by many things, but the most likely is either the ignitor has failed, or the flame sensor has failed. Make sure the gas manual gas valve is open. ...
...an igniter in minimax Pentair 472604 Igniter Replacement MiniMax NT STD Pool and Spa Heater The ignitor is simple to replace, It is either a spark ignitor or a Hot surface ignitor. The above link ...
heater problem everything seems to be powering up fine but i think the problem is the ignitor .. i smell gas but i hear the clicking for the ignitor but will not ignite This is a bad ignitor. If the ...
heater problem everything seems to be powering up fine but i think the problem is the ignitor .. i smell gas and i hear the clicking for the ignitor but will not ignite bad ignitor. I had the same ...
repair hot surface ignitor Can you tell me the easiest way to remove & replace a bad hot surface ignitor Be positively sure the power is off before opening the heater. After removing the door, look ...
heater will not come on...gas flows but no igniton...measured voltage to the ignitor=92vac..resistance of ingitor= 60 OHMS Ive never heard of an ignitor on this model getting 92 VAC. It should be 120 ...
i have an mini max nt w 6800 controls ignitor i have an mini max nt w 6800 controls ignitor keeps burning up. volts read 240 to the ignitor. maybe bad IID? The voltage to this ignitor should only be ...
...stands for "ignition failure". This can be caused by many things, but the most likely is either the ignitor has failed, or the flame sensor has failed. Make sure the gas manual gas valve is open. ...
Question about Hayward Pool & Spa
...hayward h4fdp and getting code io. C have a h4fdp heater and getting code io checked the wiring and ignitor they appear to be ok what could it be According to the manual, this is pointing to the ...
282 questions posted