Question about Craftsman Air Tools & Compressors
...reaching max pressure I have a 1 hp craftsman compressor with 7 gallon tank. It works great but shuts off at 110 psi its max is 125 psi. Is there a way to adjust the max shut off? Yes,but if the max ...
...condition that we should be attending to? The valve is stamped 60 max which I assume is 60 psi. Is this the correct size. The tank pressure is set for125 psi. The tank relief valve is marked 250
...max psi setting of 150.If the pressure is not reaching this or is only stabilizing at a low pressure you have an air leak around a gasket somewhere.If it is reaching 150psi and not shutting off your ...
Question about Craftsman Air Tools & Compressors
...psi max). Last night it pressured up to right at 130 psi and didn't shut off, so I shut it off manually. I haven't tried to let it pressure up until the relief valve blows for fear of damaging the ...
...max psi then cut out. Then upon reaching it's cut-in psi the motor ran slowly for a few seconds, then kicked off. I also assume you mean check valve when you refer to the non return valve. If this ...
...max pressure0f 150 psi is reached ,,and restore pressure upon usage?? The pressure regulator on an air compressor is designed to let the pump motor run until the pressure in the tanks reaches ...
Question about Air Tools & Compressors
...reaching max pressure? My air compressor shuts down when it reaches about 70 psi. Have changed the regulator, but problem still exist. The pressure switch needs adjusting or replaced. The power cord ...
...when the holding tank reaches its max psi. When the switch starts to malfunction, it will shut the compressor off early and eventually fail due to overheating of the internal components of the
...max PSI is Reached, instead of cutting out and still running? does anyone have a solution. Dont understand the question , does the engine shut off after p-max is met , or does it continue to run , if ...
Question about Ingersoll Rand Air Tools & Compressors
when reached max psi, the compressor will not shut off. The pop-off valve pops off. check to see if the pressure switch is opening