5500 watt generator will not run my 2hp air compressor 5500 watt generator will meet the 1491.4 watt requirement of the 2 hp compressor motor given that 5500 watts generator is rated continuously at ...

Ad

Question about Watts Electrical Supplies

1 Answer

Onan 5500 5.5 hgjae-2135b troubleshoot Onan 5500 5.5 hgjae-2135b troubleshoot What is the problem?

Ad

Question about Watts Electrical Supplies

1 Answer

Physical location of control board on an Onan 5500 Where is the control board physically located on an Onan 5500 watt generator? It is right behind the start switch. There is one bolt that holds your ...

Question about Watts Electrical Supplies

1 Answer

5500 marquie gold startes run for a few nim thin 5500 marquie gold startes run for a few min thin stop will not prime for short time thin it will restarts shut fuel off at tank, pull fuel line off ...

Question about Northstar Electrical Supplies

1 Answer

how to flash field north star 5500 generator how to flash north star 5500 generator wire a 120v 15a to 9vdc or 12vdc battery make sure you have no voltage out of the 240 side. with the unit running ...

where is the fuse on the onan 5500 built in generator? You can run the ac from shore power (house) or portable generator but not from inside. Try under the bench seats around the table, near the ...

Question about Watts Electrical Supplies

1 Answer

We have a Valsi 5500 watt generator that isn't putting enough voltage out to run everything in out small travel trailer. It runs the lights but doesnt push out enough voltage to carry the A/C, ...

Question about Northstar Electrical Supplies

1 Answer

Northstar 5500 - no power output, but motor runs fine Motor runs fine, but the generator is not giving power to the plugs... Is the Output switch in the "ON" position...the switch is normally on the ...

Question about Onan Electrical Supplies

1 Answer

onan 5500 generator in raptor will run strong for about 15 minutes and then shuts down on its own? Is the unit LP or gasoline

Question about Watts Electrical Supplies

1 Answer

5500 onan generator I changed the oil in generator and then went to start the generator. It will start then shut off. It shows three blinks on the start button. Please give me an idea! Check the oil ...

Not finding what you are looking for?
Coleman Powermate Powermate 5000W Generator Logo

849 questions posted

Ask a Question

Usually answered in minutes!

Top Coleman Electrical Supplies Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

john h

Level 3 Expert

29492 Answers

Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...