Question about Kitchen Appliances - Others
...WOULD BE THE HEAD PRESSURE AND SUCTION PLEASE NOT MAKING ICE WITH A HEAD PRESSURE BETWEEN 180 AND 210 low on refrigerant. at the beginning of the freeze cycle head pressure should be around 250-260 ...
...during harvest. The board is picking up a fault. You could have a thermister problem on the suction
Question about Scotsman Kitchen Appliances - Others
...Suction pressure ( PSIG ) 35-37 - end of freeze, 120-125-Peak in harvest. 6. Discharge pressure ( PSIG ) 240-260- 5 min in freeze. 165-175- minimum in harvest. 7. Metering device.( TXV plus ...
Question about U-Line Kitchen Appliances - Others
...suction pressure to see if it is lower than normal. Check the suction line to see if it is WARM - near room temperature. Check the compressor discharge to see if it is hot. check the Condenser to see ...
100 questions posted
Usually answered in minutes!
5 Questions
0 Questions