Question about Astoria Argenta Coffee Makers & Espresso Machines
...pressure stat or the reset thermostat on the boiler left side if the model is equipped with one, has tripped, possibly because the machine is low on water in the boiler or the contacts for the ...
Question about Astoria Argenta Coffee Makers & Espresso Machines
...the problem is the vent valve or the safety valve, if it is the safety then the pressure stat needs to be replaced because it might be damaged or blocked at the tube that connects it to the
...in the boiler before pressing reset and turning machine to number 2. After machine heats up make sure pressure does not go past 1.5 bars on the gauge. If it does then the p.stat needs to be
Question about Astoria Argenta Coffee Makers & Espresso Machines
...on the pressure stat (rectangular box with 4 wires going to it), you will see the wires, two from switch and two to element. Make sure there is water in the boiler and test machine (connect to
...pressure safety valve is open when this pressure increse more the 2 Bar Sounds like the the tube that connects to the pressure stat is blocked or the pressure stat is damaged and needs to be
Question about Grindmaster Coffee Makers & Espresso Machines
building to much pressure getting to hot Pressure stat bad and or boiler is limed up.You may want to check the pressure line from tank to pressure stat is clear.
...pressure stat and his pipe which connects to boiler.(pressurestat kan be broken or pipe kan be blocked) the heating element can be broken and it by pass the pressure stat by closing circuit with ...
pressure stat on the right side, with 2 wire connections going to it. That P.stat could be damaged and needs to be replaced, or the pipe to the P.stat is clogged and it cannot read the boiler pressure
The boiler in my Franke ecolino coffee maker is over heating. Anyone have a solution? you most likely need a new pressure stat/switch as it is what tells the elements to turn off and quit heating.
...pressure stat on the right side of the machine below top panel, screw is marked with red paint. It is possible that there is something else going on, check the hse that leads to the pressure stat and ...