failure 3 2 1 3 2 1 3 2 1 EXP (CR8) See log (CR17) NMI (CR7) Over Temp (CR9) PCI (CR19) VRM (CR13)
DASD (CR15) Out of Spec (CR14) PS2 (CR11) Remind button (SW1) SP bus (CR4) Fan (CR6) Mem (CR3) CPU (CR18) Non Redund (CR16) PS3 (CR10)
more...
64 IBM® xSeries 360: User's Reference
DASD Hard disk drive failure Out of Spec Power supplies being overdriven PS2 Power supply number 2 failure Remind button Remind to invoke remind mode
more...
LEDs are as follows: EXP Attached expansion I/O failure NMI Nonmaskable interrupt Over Temp System over temperature condition PCI PCI failure VRM VRM failure
DASD Hard disk drive failure Out of Spec Power supplies being overdriven PS2 Power supply number 2 failure Remind button Remind to invoke remind mode
more...
swap 62, 121 power-on password override 18, 62 K keyboard port 90 L LAN, connecting 28 LAN, Ethernet 23, 91 LEDs CPU 64, 124
DASD 64, 124 EXP 63, 124 FAN 64, 124 Level 2 Diagnostics 124 MEM 64, 124 memory board DIMM error 65 NMI 63, 124 Non
more...
service. On FAN One of the fans has failed or is operating too slowly. Note: A failing fan can also cause the TEMP and
DASD LEDs to be on. Remove the top cover. The LED on the failing fan will be lit. Replace the fan.
more...
lit microprocessor error LED, and restart the server. 3. If the problem remains, replace the microprocessor. If the problem remains, call for service. On
DASD A hot-swap hard disk drive has failed. 1. If the amber hard disk drive status LED on one of the hot-swap hard disk drives
more...
Sponsored Links