Procom ML300EBC Heater "4" Questions

Ad

I bought new Honeywell non programmable,letters are different. On the old base is a #4 that a blue wire was attached to and that goes to the gas valve, the new base doesn't have that #4. My wiring is ...

Ad

Question about Goodman Heating & Cooling

1 Answer

4 BLINKS AFTER 4 MINS OF RUN TIME Change the filter. I believe 4 blinks is for a failure on the high limit switch.

Ad

Question about Heating & Cooling

1 Answer

Gas boiler will not fire My pilot lights, then burners light and then 4 seconds later they go out and the process repeats itself. At first I thought it was the flame sensor, so I unplugged it and ...

Replacing thermostat. New programable thermostat installation diagram shows 4 wires. There's only two wires coming from the wall. Will the programable thermostat work with 2 wires? Yes it will. 4 ...

Question about Lakewood Heating & Cooling

2 Answers

...2 must be the opposite of terminal 1, such that when switched on, 1 & 2 connects. Terminal 4 must be the opposite of terminal 3, such that 3 & 4 connects. Under this setup, you may ...

...How many watts? What are the dimensions? This heater is 1500 watts. It's dimensions are 8 1/4 X 6 1/4 X 14 1/4. It comes in a steel case and is gray in color. Here is the company website

hi i have a room thermostat with 4 programs per day on it. in the book it doesn't say if program 2 & 4 are the off times and if 1 & 3 are the on times. the thermostat was bought from wolseley.

Question about Goodman Heating & Cooling

1 Answer

goodman furnace GSM100-4 model has constant ligt blinking. Will fire all burners and in few seconds shut off. Help for what ever reason, your shutting down on high temp 4 things to check 1 the filter ...

Question about Dayton Heating & Cooling

2 Answers

dayton 70,000 btu kerosene heater only runs consistently with 3/4 of a tank of fuel or more. Once it is below 3/4 it keeps shutting off. I have cleaned filters, tried to set pressure but pressure ...

gsm080-4 4 blinks on code cover says main limit open or aux limit can i check them or not?where are they located. iits been runntssat morning and temp is -12degrees out. iwaited for gas valve to kick ...

Not finding what you are looking for?
Procom ML300EBC Heater Logo

18 questions posted

Ask a Question

Usually answered in minutes!

Top Procom Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Procom Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions