sharp code h3-00 copier is ar-507, with the error code of h3-00 how do i fix this heat roller high tempareture detection
...code h3-00 indicate? turned off and cooled but error still shows Sharp ARM 550/620/700 Reset Machine with Error Code ... ? 1:26 www.youtube.com/watch?v=BXs8PmMXFtk May 5, 2011 - Uploaded by Thomas ...
...May 5, 2011 - Uploaded by Thomas Trumpler Thomas Trumpler: error code H3-00 I tried this and got to the last step and there was no option using 1 for yes and 2 for no, so I ended up
H3 ERROR CODE SHARP AL 1631 I REPLACED THE FUSER LAMP AND ERROR CODE STILL BLINKING H3. H3: 00:TEMPERATURE OF FUSER UNIT HIGH,THERMISTOR CONTROL BOARD FAILING Did you replace the thermistor? check the
Question about Sharp Office Equipment & Supplies
I have a service code of H3-00 on a sharp ar405 copier -can anyone help Thank you H3 00 Heat roller high temperature detection
I have a service code of H3-00 on a sharp.AR 337 Copier. can anyonehelp Thank you H3 00 Heat roller high temperature detection
...H3-00 Hello sir; This error code require a reset procedure ; press "#", "*", "clear", "*",these four keys by order, then enter 14 press start. then turn power off and back on. thanks for giving ...
...code as above H3 - 00. This means High Temperature in the heater section, proberbly caused by a faulty thermistor. Firstly try a reset, please press the following buttons IN SEQUENCE:- Program - ...
...code H3-00 I have a Sharp copier that developed an Error code when it is turned on. The Error code is H3-00. Any help would be appreciated. H3-00 means there was a problem in the fuser unit of the ...
...code h3-00 H3-00: Heat roller high temperature detection Check and remedy:- Check heater lamp operation with SIM5-2. If lamp blinks properly: Check thermistor and its harness. Check thermistor input ...