pilot light wont light Gas Boiler pilot light wont light If it is a thermocoupler type pilot safety, clean pilot and replace thermocoupler, Good luck.If it has a powerpile generator, replace generator

Ad

Question about Heating & Cooling

1 Answer

...pilot light but heater wont light. the problem is the thermocoupler. it is the other small tube next to the pilot light. this tube sends a signal to the main valve to let the fuel go through. ...

Ad

Question about Procom Heating & Cooling

1 Answer

...pilot light wont light I have a procom ventless fireplace. I tried to get the pilot lit this year and It wont light. I have gas all the way to the fireplace but nothing coming out at pilot. I have ...

...on... it calls for heat, sparks and the furnace ignites and runs fine till the next time the pilot wont extinguish. Is it my box, thermostat, pilot light or what? this sound like you gas valve is ...

...light will not light. This is a new installation. make sure the thermocouple is sitting 3/8 to 1/2 inside the pilot flame when lighted. if it isn't, it wont generate enough dc current to keep pilot ...

Question about Heating & Cooling

1 Answer

...pilot light wont stay lit i have a propane furnace for a heater and my pilot light wont stay lit i replaced the thermo coupling Hi try cleaning the pilot light out make sure the thermo couple is in ...

Question about Heating & Cooling

1 Answer

pilot light wont light cant get the pilot light to light Rita, Check the attached links,instruction and guides to trouble shoot pilot light, Good luck "I hope this helped you out, if so let me know by

ok changed thermocupling,pilot lit still wont come on. pilot lit ,furnance wont turn on,put new thermocuping,still wont turn on Once you light it, does the pilot remain lit?

Question about Heating & Cooling

1 Answer

pilot light lights but burners wont light If this is a stovetop, there are little holes on the side of the burners were the tube from the pilot light goes, they are probably clogged not allowing gas ...

my furnace pilot light wont light, have check gas-its on but coming through to allow pilot to start Replace pilot orifice in pilot assembly.

Not finding what you are looking for?
Procom QL300TYLA Heater Logo

44 questions posted

Ask a Question

Usually answered in minutes!

Top Procom Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66944 Answers

Are you a Procom Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...