...unit. Where can I get fittings to adapt to your machine? It may be a 410a unit. regular R22, R134 gauges will not work. You will need 410a gauges as it has much higher pressure in the
Question about Amcor Heating & Cooling
...side. Is there an adaptor to accomplish this opportunity? yes there is an adapter to reduce to fit 410a hoses, go to a HVAC supply company they have ...
...# indicates this is a 3 ton unit how big is your house? Hi, I thought I would add, that on a R-410a unit/A-20 has extremely high refrigerant pressures in the system. The superheat and
...if it is running on freon 22 as this gas will not operate below 5 deg C. if it running on freon 410a then it can run as low as -5 deg C Something else to consider is the out side
...410A fittings are different than the r-22 fittings. There are adapters available on ebay. Remember 410A runs at higher pressures than 22. Be sure to use gauges for 410A! Use the right gauges with the ...
...410A, unless there is a leak in one of the coils, these unit have flare fittings, where the copper lines hookup to the units, and it is a good idea to check and make sure that the fittings are tight. ...