compressor running, but not cooling - No freon in the system, or compressor valves are bad, not compressing freon. Ideal would be to check pressures on the system while its running. Could be some kind
not running, compressor fault. If compressor running but no heat in condenser, short of gas. If compressor running and heat only in first rungs of condenser, compressor poor pumper and needs replacing
...compressor running hot if its not hot and the fan by the compressor is running the problem is that the compressor is not starting check the compressor you might need a new start relay mounted on the ...
...compressor itself is running. If there is a loose connection to the compressor via the start/over load relay (normally attaches directly onto the compressor), or if the start/over load itself is bad ...
...compressor running condition. (set to lowest temperature and let the doors open. the compressor must run contineously. Feel if it is cooling up. If so then close the doors and observe the compressor ...
Question about Franklin Industries Refrigerators
...compressor rotor. If it is actually starting but not running at full speed / normal RPM the run capacitor can also be bad. Unless the compressor is locked up... the cost to repair the unit is worth ...
...Compressor not running, its quite possible that compressor is faulty.But there is one more possibility, there is start up capacitor ,also known as run capacitor.This is beside the compressor.If this ...
Question about Refrigerators
...compressor running? Check compressor is it running is fan running near compressor? Feel compressor. If running it vibrates if its smoking hot the over load protector may have gone bad thats the small ...
Question about Refrigerators
...running. Compressor fan running, no fans in freezer running, dont think compressor is. Room temp both sides Try using a listening stick, screwdriver or a sonascope held in firm contact with the ...
...not running at all, not even clicking, then board or thermostat is most likely the problem. If compressor is running or trying to run, then starting device for compressor or compressor itself is