Maytag M7DH65B2A Dehumidifier "condensor turn" Questions

Ad

Question about Comfort-Aire Dehumidifiers

1 Answer

...condensor will not turn on kfr, 24w soleus air heat pump Check the contactor to see if the contacts are stuck or welded together, if not check to see if you have 24 volts to the contactor, if you do ...

Ad

Question about Friedrich Dehumidifiers

1 Answer

...empty collecting no water.What should I do? Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off ...

Ad

Question about Maytag Dehumidifiers

1 Answer

...condensor coil. This protector will turn the compressor off should the temperature fall below 65 degrees in the basement. The condensor fan will still continue to run anticipating the restart of the ...

Question about Ebac Dehumidifiers

1 Answer

...condensor coil. Also, if the humidity is too low, (below 45%), the same condition will occur. So it will help to keep the parameters in mind when you have this issue. If your model does not employ a ...

Question about Dehumidifiers

2 Answers

turn the humidistat to constant and have something happen. Nothing is happening. I'm completely untechnical and I know there could be some basic thing I'm not doing. (I don't have the instruction book

Question about Goldstar Dehumidifiers

2 Answers

...percentage. Still no water collected. Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off ...

Question about Friedrich Dehumidifiers

2 Answers

...bucket). Any suggestions to check? Thanks Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off ...

Question about Kenmore Dehumidifiers

1 Answer

...issues may vary, but the theory is the same. Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off ...

Question about Maytag Dehumidifiers

3 Answers

...condensor. Can you help? CHANCES ARE THE DUAL CAPACITOR HAS BLOWN APART...YOU WILL KNOW THIS IF THE SIDE WALL IS RUPTURED. THE CAPACITOR IS LOCATED TO THE RIGHT OF THE COMPRESSOR MOUNTED WITH 1/4 HEX ...

...issues may vary, but the theory is the same. Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off ...

Not finding what you are looking for?
Maytag M7DH65B2A Dehumidifier Logo

232 questions posted

Ask a Question

Usually answered in minutes!

Popular Products

Top Maytag Dehumidifiers Experts

Paul Carew

Level 3 Expert

3807 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66772 Answers

goneforever.

Level 3 Expert

14531 Answers

Are you a Maytag Dehumidifier Expert? Answer questions, earn points and help others